10.  Warranty

Limited Warranty Supplied by Dual Pumps Ltd

Dual Pumps Ltd as suppliers warrants to the original purchaser, each new unit 

or other product supplied from its factory, for the period of twelve (12) months 

from the date of shipment from the factory, six (6) months for equipment on hire 

or rental), to be free from defects in material and workmanship under normal use 

and service. “Normal Use and Service” means not to exceed recommendations on 

maximum speeds, pressures and temperatures or handling fluids not compatible 

materials, as noted in the applicable Dual Pumps catalogue, technical literature 

and instructions. This warranty shall not apply to any pump or other product, which 

has been repaired or altered, to adversely affect the performance or reliability of 

the pump or product. Lance or hoses are not covered by this warranty due to the 

adverse conditions of their use.

Neither this warranty nor any implied warranty apply to damage caused by any 

of the following:

1. Freight damage

2. Frost or freezing damage

3. Damage caused by parts and/or accessories or components not obtained  

  from or approved by Dual Pumps Ltd.

4. Any consequential or incidental damage arising from the use of any, pump or  

  other products supplied by Dual Pumps Ltd.

5. Damage due to misapplication and/or misuse. The normal wear of moving  

  parts or components affected by moving parts.

The liability of Dual Pumps Ltd under the foregoing warranty is limited to the repair 

or replacement at Dual Pumps Ltd option without charge for labour, mileage costs 

or materials of any parts upon return of the entire pump or other product or of 

the particular part to the Dual Pumps Ltd factory within the warranty period at 

the sole expense of the purchaser, which part shall upon examination appear to 

Dual Pumps Ltd satisfaction to have been defective in material or workmanship. 

The liability of Dual Pumps Ltd under any theory or recovery (except any express 

warranty where the remedy is set forth in the above paragraph) for loss, harm or 

damage, shall be limited to the lesser of the actual cost, harm or damage, or the 

purchase price of the involved pump or other product when sold by Dual Pumps 

Ltd to its customer. Dual Pumps Ltd expressly warrants its pumps or other products 

as above stated.

There are no other express warranties. Any implied warranties, including implied 

warranty of merchantability or of fitness for a particular purpose, are limited in 

duration to twelve (12) months from the date of the purchase by the original

Summary of Contents for CF10135PHR

Page 1: ...Model Serial No Engine No Year of Manufacture CE Pressure Washer Operating Instructions 793 1200 pumps...

Page 2: ...ion to operate the Dual Pumps range of Pressure Washers safely and effectively It is recommended the manual and its accompanying literature be read and understood before attempting to assemble or oper...

Page 3: ...i cylinder plunger Pump 8 lpm 30 lpm 100bar 250bar pump pressure Transport frame Rigid steel frames in either static or wheeled options EC DECLARATION OF CONFORMITY Dual Pumps Ltd Unit 8 Hudson Road S...

Page 4: ...F14150PHR Petrol6 5Hp 14 150 38 580x410x455 106 111 1 D DS14150PHR Petrol 6 5 Hp 14 150 45 680x580x820 106 111 1 D DT14150DLR Diesel 6 8Hp 14 150 73 970x630x850 109 115 2 J RT15200PHR Petrol 11Hp 15 2...

Page 5: ...least EN352 1 EN352 2 3 3 Use in confined spaces Diesel and Petrol engines produce fumes and toxic gases use only in well ventilated spaces To prevent the build up of flammable vapours the charging of...

Page 6: ...personal protective equipment to employees who may be exposed to risks affecting their health and safety Full Face Protection High speed flying partials or chemical splashes are rarely aimed directly...

Page 7: ...ox Dipstick Depending on Model 15 Pump Sight Glass 6 Gearbox Sight Glass Depending on Model 16 Return external return to water supply depending on model 7 Hand Lance 17 Suction Filter 8 High Low Press...

Page 8: ...tor and place the other end in the water supply container Bypass to tank models only Fig 2 item 16 Fig 4 5 6 Submerge the opposite end of the suction hose and its suction filter in a suitable containe...

Page 9: ...cing the opposite filter end into the detergent container Select the low pressure setting on the lance see appendix 1 for details of your lance and spray the water detergent mixture onto the object be...

Page 10: ...ours 100 hours Inspect top up oil levels Engine Gearbox Pump Change Oil Gearbox EP90 Gear Oil Pump SAE30 Pump Oil Change engine oil in line with the engine First 3 manufacturers recommendation or at m...

Page 11: ...ng air Check integrity of suction hose and connections Excessive temperature of Reduce temperature to liquid in pump below 60 C do not allow pump to idle for long periods Worn bearing or valves Seek p...

Page 12: ...ncidental damage arising from the use of any pump or other products supplied by Dual Pumps Ltd 5 Damage due to misapplication and or misuse The normal wear of moving parts or components affected by mo...

Page 13: ...nt must despatch the unit product or part at his own expense to the Dual Pumps Ltd factory with a full detailed report for inspection upon receipt Dual Pumps Ltd will inspect and decide whether the un...

Page 14: ...Appendix 1 Lance variations LOW PRESSURE JET HIGH PRESSURE JET...

Page 15: ...Unit 8 Hudson Road Saxby Road Ind Est Melton Mowbray Leicestershire LE13 1BS Telephone 44 0 1664 567226 Fax 44 0 1664 410127 E mail info dualpumps co uk www dualpumps co uk pumps...

Reviews: