Inrush Current
To prevent damages to the MC50M due to exceeding inrush current, take the measured
inrush current values into account when designing your circuit protection.
Table 6.
Inrush current measurements on PWR_IN
3.1.5
Power Cable
duagon offers a starter kit including a power cable (5-pin M12 to Euro plug).
Input Voltage
Inrush Energy I²t
Inrush Current
(Peak)
16.8 V DC min.
0.042 A²s
27 A
24 V DC nom.
0.089 A²s
41 A
48 V DC nom.
0.353 A²s
82 A
60 V DC max.
0.507 A²s
98 A
See the duagon website for ordering information: