3- VOLTAGE AND FREQUENCY:
Delta R can operate at 90-270V, 50 or 60 Hz.
4- INSTALLATION:
4.1 Safety cable:
4.2 Risk of fire:
Each fixture produces heat and must be installed in a well-ventilated position. The minimum
recommended distance from flammable material is 1m. Minimum distance from the object being
illuminated is 30 cm.
Delta R may be either floor or ceiling mounted.
For floor mounting installations, the unit is supplied with four rubber mounting feet on the base.
For ceiling mounted installations, we reccomend the use of appropriate clamps to fix the unit to the
mounting surface.
The supporting structure from which the unit is hung should be capable of bearing the weight of the
unit, as should any clamps used to hung it. The structure should also be sufficiently rigid so as not to
move or shake whilst the Delta R is moving.
Four quarter turn fast locks placed on the base of the units,allows by using the two fast lock C clamps
provided in the box, to fix the unit in any position.
.
We recommend the use of a safety cable or chain connected to the Delta R and to the suspension truss
in order to avoid the fixture accidentally falling should the main fixing point fail. Make sure that the iron
cable or chain can bear the weight of the entire unit.
You may attach the safety chain to the holes located on the base of the fixture, as shown in the picture
below.
6
DELTA R
SAFETY CABLE
FIXING POINT
www.bluelight.at