4.3 Ambient temperature:
The projector should never be installed in places that lack a constant air flow. The ambient temperature
should NOT exceed 45°C.
5- MAINS CONNECTION:
Delta R can operate at 90-270V, 50 or 60Hz.
For connection purposes, ensure that your plug can handle at least 300W power consuption.
Strict adherence to regulatory norms is strongly
Recommended.
5.1 Protection:
The use of a thermal magnetic circuit breaker is recommended for each Delta R.
A good earth connection is essential for the correct operation of the projector.
6- DMX SIGNAL CONNECTION:
The unit operates using a digital DMX 512 (1990) signal. Connection between the control box and the
projector or between projectors must be carried out using a two pair screened ø0.5 mm cable and a
CANNON XLR 5 or 3 pole connector.
P.S:
If the display showing the DMX address flashes, then one of the following errors has occurred:
- DMX signal not present
- DMX reception problem
Ensure that the conductors do not touch each other.Do not connect the cable ground to the XLR chassy
The plug housing must be isolated. Connect the mixer signal to the DMX IN projector plug and connect
it to the next projector by connecting the DMX OUT plug on the first projector to the DMX IN plug of the
second one.
In this way, all the projectors are cascade connected.
5
3
4
2
1
1=GND
2=DATA-
3=DATA+
CONTROLLER
S T A N D A R D
DM X 5 1 2
OUT
IN
OUT
7
DELTA R
Electronic ballast
90-270V 50 / 60Hz
OUT
OUT
IN
IN
DMX IN
DMX OUT
FUSE: T 3,15A
MAINS
www.bluelight.at