background image

DELTA 8 R

14

13- DISPLAY FUNCTIONS

DMX Set

Up-Down

Up-Down

ENTER

DMX mode
RGB 15 channels (Default)
RGBW 16 channels (Reserved for 
future use)

ENTER

Menu

DMX MODE / MACRO
DMX Mode 
To select DMX mode : 

Macro
Macro Function, enable channel 
mapping macro rainbow effects
STD (default) 

RGB 15 channels 

(Default)
RGBW 16 channels (Reserved for future 
use)

MENU ENTER DOWN

UP

20 ch

DMX SET

DMX MODE

MENU ENTER DOWN

UP

RGB 15CH

DMX SET

DMX MODE

MENU ENTER DOWN

UP

20 ch

DMX SET

DMX MODE

MENU ENTER DOWN

UP

STD

DMX SET

MACRO

MACRO
Standard mode enabled (Default)
Extended mode enabled: Rainbow 
effects on MACRO channel
 

LED

Up-Down

Up-Down

ENTER

RED Min default =0
RED Max default = 255

ENTER

Menu

MENU ENTER DOWN

UP

20 ch

DMX SET

DMX MODE

MENU ENTER DOWN

UP

0

LED

RED MIN

RGBA MINIMUM VALUES
This menu allow to select the 
minimum levels for Red, Green, and 
Blue

RGB MAXIMUM VALUES
This menu allow to select the 
maximum levels for Red, Green,
and Blue

These settings have priority on 
Master Dimmer (DMX channel 7)

SMOOTH VALUE
This menu allow to select the value 
of the delay ( in millisecons) for 
RGBA and Dimmer channels  
reaction to DMX or Program 
variation.
4 = 25 ms delay (Fast response)
20 = 250 ms delay (Slow response)

GAMMA CORRECTION
This menu allow to select between
Linear current output  or Quadratic 
current output for LEDs.
Default = Quadratic

OUTPUT FREQUENCY
This menu allow to adjust the PWM 
frequency value (Hz) in order to 
reduce flickering in the process of 
your camera recordings

BOOST DRIVING
This menu allow to increase the 
LED’s current from 350mA to 500 
mA

MENU ENTER DOWN

UP

20 ch

DMX SET

DMX MODE

MENU ENTER DOWN

UP

0

LED

GREEN MIN

MENU ENTER DOWN

UP

20 ch

DMX SET

DMX MODE

MENU ENTER DOWN

UP

0

LED

BLUE MIN

MENU ENTER DOWN

UP

20 ch

DMX SET

DMX MODE

MENU ENTER DOWN

UP

0

LED

AMBER MIN

BLUE Min default =0
BLUE Max default = 255

GREEN Min default =0
GREEN Max default = 255

AMBER Min default =0
AMBER Max default = 255

NO FUNCTION ON DELTA 8 R

 

MENU ENTER DOWN

UP

20 ch

DMX SET

DMX MODE

MENU ENTER DOWN

UP

4

LED

SMOOTH

SMOOTH
Range = Off - 20
Default = 4

MENU ENTER DOWN

UP

20 ch

DMX SET

DMX MODE

MENU ENTER DOWN

UP

RGBW 16CH

DMX SET

DMX MODE

RGBW 16 channels (Reserved for 
future use)

NO FUNCTION ON DELTA 8 R

Summary of Contents for Delta 8 Full Colour R

Page 1: ...hnical Datasheet hnical Datasheet GB Made in Italy DELTA 8 R User s Manual rel 1 1 D T S Illuminazione srl ITALY http www dts lighting it DELTA 8 WHITE AMBER R DELTA 8 RGB R DELTA 8 FULL COLOUR R...

Page 2: ...cts or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ventuelles...

Page 3: ...ration of solid and liquid objects 8 VOLTAGE AND FREQUENCY 9 9 INSTALLATION 9 9 1 Safety cable 9 2 Protection against liquids 9 3 Movement 9 4 Risk of fire 9 5 Forced ventilation 9 6 Ambient temperatu...

Page 4: ...lamp The lamp must be replaced if it has been damaged or deformed by prolonged use or overheating The device must always be equipped with an efficient ground connection 3 GENERAL WARRANTY CONDITIONS T...

Page 5: ...8 x 1W P4 type White Amber LEDs 72 White 36 Amber Delta 8 FULL COLOUR R 36 x 3W P5 II Full colour LEDs LEDs average lifespan 100 000 hours Colour temperature variable on a linear range 2800 K 6500 K N...

Page 6: ...on horizontal and vertical 1 axes Movements horizontal pan vertical tilt axes Thermal Operating ambient temperature 10 40 Finishes Black or white finish Certification and Safety Certification CE LED...

Page 7: ...User s manual Flight cases Flight case for 1 DELTA with no wheels cod 0521C029 Standard Flight case with wheels for 2 DELTA cod 0521C030 Professional Flight case with wheels for 2 DELTA cod 0521C030 1...

Page 8: ...connection is essential for proper functioning of the projector Never connect the unit without proper earth connection The fixture should be located in places with a good air ventilation 7 3 Safety Th...

Page 9: ...ections placed in the base of the units allow to hang the DELTA 8 R by using the Fast Lock C clamps provided in the box 9 1 Safety cable We recommend the use of a safety chain cord connected to the DE...

Page 10: ...projector should never be installed in places that lack a constant air flow The ambient temperature should NOT exceed 40 C 10 MAINS CONNECTION DELTA 8 R operate at 90 260 VOLT 50 60 Hz Prior to conne...

Page 11: ...the projectors are cascade connected NB If the display showing the DMX address flashes then one of the following errors has occurred DMX signal not present DMX address not valid DMX reception problem...

Page 12: ...service centre D T S Firmware upgrade utility program D T S Firmware upgrade utility 12 FIRMWARE UPDATING Warning This procedure require a base knolewge of Windows based computer applications To updat...

Page 13: ...nction DELTA 8 R 13 MAINS Electronic Power supply 90 260V AC 50 60Hz External ANTENNA panel connector Wireless DMX DMX OUT DMX IN Fuse 5A T 5X20 MENU ENTER DOWN UP DISPLAY Display Up Down Up Down ENTE...

Page 14: ...H VALUE This menu allow to select the value of the delay in millisecons for RGBA and Dimmer channels reaction to DMX or Program variation 4 25 ms delay Fast response 20 250 ms delay Slow response GAMM...

Page 15: ...nu allow to select the LED s driving current 350 500 mA AUTO Up Down Up Down ENTER Menu MENU ENTER DOWN UP 20 ch DMX SET DMX MODE MENU ENTER DOWN UP AUTO SURE Menu NO Enter YES ENTER AUTOMATIC MODE Au...

Page 16: ...m MASTER unit set in AUTO MODE in order to ran the units in SLAVE mode By setting all the SLAVE units connected to the MASTER to DMX address 1 them will be sinchronized with the Master unit following...

Page 17: ...t modes are possible 1 Antenna transmitter has detected and transmits a DMX signal in this mode a solid green light is seen on the transmitter and solid display is seen on DELTA 8 R 2 No DMX signal co...

Page 18: ...will be possible to select one of the 16 preprogrammed WHITE cues that will then ran if DMX signal is missing or not available Usefull for Emergency EXIT ilumination on public areas Dimmer level Pan a...

Page 19: ...Up Down ENTER Menu TEMPERATURE Unit temperature MENU ENTER DOWN UP 20 ch DMX SET DMX MODE MENU ENTER DOWN UP 13 Hr 08 min TIME TIME Up Down ENTER Menu LIFE TIME This menu show the total UNIT life tim...

Page 20: ...t Normal or Reversed PAN TILT SPEED Pan Tilt Speed control 1 4 PAN INVERTION Default NORM TILT INVERTION Default NORM PAN TILT SPEED CONTROL Default 4 FAN MAX SPEED This menu allow to select the inter...

Page 21: ...TER on the selected GAME By setting all the units connected to the MASTER to DMX address 1 them will be sinchronized with the Master unit following the chase selected on it including TIME WAIT Pan and...

Page 22: ...n Disconnect mains power before any servicing or maintenance Fuse replacement Locate the fuse which protect the electronics in the base of the unit Using a multimeter test the condition of the fuse re...

Page 23: ...SET DMX CHANNEL 1 Parameter PAN msb DMX CHANNEL 2 Parameter PAN lsb DMX CHANNEL 3 Parameter TILT msb DMX CHANNEL 4 Parameter TILT lsb DMX CHANNEL 5 Parameter SPEED MOVEMENT DMX range Value Mid point D...

Page 24: ...point Move DMX range Mode Option Function range Value DMX value degrees 0 7 Black out 8 255 Proportional dimmer Proportional colour 0 255 degrees Value DMX value range Option DMX range Mid point Mode...

Page 25: ...ure correction 0 2800 K 255 6800 K 156 205 180 Custom White Create RGB levels selectable by DMX 206 255 230 White CTC Channel 12 CTC enabled DMX CHANNEL 13 Parameter COLOUR MACROS DMX range Value Mid...

Page 26: ...1 6 Sec Rainbow Speed 2 15 Sec Rainbow Speed 3 30 Sec Rainbow Speed 4 45 Sec Rainbow Speed 5 60 Sec Rainbow Speed 6 120 Sec Rainbow Speed 7 150 Sec Rainbow Speed 8 180 Sec Please refer to page 14 for...

Page 27: ...X IN 50 cm cable with Neutrik XLR 5 pins Male cable connector on board 1 x DMX OUT 50 cm cable with Neutrik XLR 5 pins Female cable connector on board DELTA 8 R 27 Main AC IN power cord 3 x 1 5 sq mil...

Page 28: ...ic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein D T S Illumina...

Reviews: