background image

DELTA 8 R

18

MENU ENTER DOWN

UP

20 ch

DMX SET

DMX MODE

MENU ENTER DOWN

UP

OFF

EMERGENCY

SELECTION

EMERGECY

Up-Down

Up-Down

ENTER

Menu

EMERGENCY
ON = Enabled
OFF = Disabled (Default)

MENU ENTER DOWN

UP

20 ch

DMX SET

DMX MODE

MENU ENTER DOWN

UP

1

EMERGENCY

WHITE

MENU ENTER DOWN

UP

20 ch

DMX SET

DMX MODE

MENU ENTER DOWN

UP

255

EMERGENCY

DIMMER

EMERGENCY 
Emergency operating mode.
By setting Emergency mode, it 
will be possible to select one of 
the 16 preprogrammed WHITE 
cues that will then ran if DMX 
signal is missing or not available.
Usefull for Emergency EXIT 
ilumination on public areas.
Dimmer level, Pan and Tilt 
values selectable by user.

WHITE 1-16
Default = WHITE 1

DIMMER
Default = 255

ENTER

13- DISPLAY FUNCTIONS

MENU ENTER DOWN

UP

20 ch

DMX SET

DMX MODE

MENU ENTER DOWN

UP

128

EMERGENCY

PAN

MENU ENTER DOWN

UP

20 ch

DMX SET

DMX MODE

MENU ENTER DOWN

UP

128

EMERGENCY

TILT

PAN
Default = 128

TILT
Default = 128

MENU ENTER DOWN

UP

20 ch

DMX SET

DMX MODE

MENU ENTER DOWN

UP

ON

EMERGENCY

SELECTION

EMERGENCY
Enabled

Summary of Contents for Delta 8 Full Colour R

Page 1: ...hnical Datasheet hnical Datasheet GB Made in Italy DELTA 8 R User s Manual rel 1 1 D T S Illuminazione srl ITALY http www dts lighting it DELTA 8 WHITE AMBER R DELTA 8 RGB R DELTA 8 FULL COLOUR R...

Page 2: ...cts or circuits described herein Les informations contenues dans le pr sent manuel ont t r dig es et contr l es avec le plus grand soin Nous d clinons toutefois toute responsabilit en cas d ventuelles...

Page 3: ...ration of solid and liquid objects 8 VOLTAGE AND FREQUENCY 9 9 INSTALLATION 9 9 1 Safety cable 9 2 Protection against liquids 9 3 Movement 9 4 Risk of fire 9 5 Forced ventilation 9 6 Ambient temperatu...

Page 4: ...lamp The lamp must be replaced if it has been damaged or deformed by prolonged use or overheating The device must always be equipped with an efficient ground connection 3 GENERAL WARRANTY CONDITIONS T...

Page 5: ...8 x 1W P4 type White Amber LEDs 72 White 36 Amber Delta 8 FULL COLOUR R 36 x 3W P5 II Full colour LEDs LEDs average lifespan 100 000 hours Colour temperature variable on a linear range 2800 K 6500 K N...

Page 6: ...on horizontal and vertical 1 axes Movements horizontal pan vertical tilt axes Thermal Operating ambient temperature 10 40 Finishes Black or white finish Certification and Safety Certification CE LED...

Page 7: ...User s manual Flight cases Flight case for 1 DELTA with no wheels cod 0521C029 Standard Flight case with wheels for 2 DELTA cod 0521C030 Professional Flight case with wheels for 2 DELTA cod 0521C030 1...

Page 8: ...connection is essential for proper functioning of the projector Never connect the unit without proper earth connection The fixture should be located in places with a good air ventilation 7 3 Safety Th...

Page 9: ...ections placed in the base of the units allow to hang the DELTA 8 R by using the Fast Lock C clamps provided in the box 9 1 Safety cable We recommend the use of a safety chain cord connected to the DE...

Page 10: ...projector should never be installed in places that lack a constant air flow The ambient temperature should NOT exceed 40 C 10 MAINS CONNECTION DELTA 8 R operate at 90 260 VOLT 50 60 Hz Prior to conne...

Page 11: ...the projectors are cascade connected NB If the display showing the DMX address flashes then one of the following errors has occurred DMX signal not present DMX address not valid DMX reception problem...

Page 12: ...service centre D T S Firmware upgrade utility program D T S Firmware upgrade utility 12 FIRMWARE UPDATING Warning This procedure require a base knolewge of Windows based computer applications To updat...

Page 13: ...nction DELTA 8 R 13 MAINS Electronic Power supply 90 260V AC 50 60Hz External ANTENNA panel connector Wireless DMX DMX OUT DMX IN Fuse 5A T 5X20 MENU ENTER DOWN UP DISPLAY Display Up Down Up Down ENTE...

Page 14: ...H VALUE This menu allow to select the value of the delay in millisecons for RGBA and Dimmer channels reaction to DMX or Program variation 4 25 ms delay Fast response 20 250 ms delay Slow response GAMM...

Page 15: ...nu allow to select the LED s driving current 350 500 mA AUTO Up Down Up Down ENTER Menu MENU ENTER DOWN UP 20 ch DMX SET DMX MODE MENU ENTER DOWN UP AUTO SURE Menu NO Enter YES ENTER AUTOMATIC MODE Au...

Page 16: ...m MASTER unit set in AUTO MODE in order to ran the units in SLAVE mode By setting all the SLAVE units connected to the MASTER to DMX address 1 them will be sinchronized with the Master unit following...

Page 17: ...t modes are possible 1 Antenna transmitter has detected and transmits a DMX signal in this mode a solid green light is seen on the transmitter and solid display is seen on DELTA 8 R 2 No DMX signal co...

Page 18: ...will be possible to select one of the 16 preprogrammed WHITE cues that will then ran if DMX signal is missing or not available Usefull for Emergency EXIT ilumination on public areas Dimmer level Pan a...

Page 19: ...Up Down ENTER Menu TEMPERATURE Unit temperature MENU ENTER DOWN UP 20 ch DMX SET DMX MODE MENU ENTER DOWN UP 13 Hr 08 min TIME TIME Up Down ENTER Menu LIFE TIME This menu show the total UNIT life tim...

Page 20: ...t Normal or Reversed PAN TILT SPEED Pan Tilt Speed control 1 4 PAN INVERTION Default NORM TILT INVERTION Default NORM PAN TILT SPEED CONTROL Default 4 FAN MAX SPEED This menu allow to select the inter...

Page 21: ...TER on the selected GAME By setting all the units connected to the MASTER to DMX address 1 them will be sinchronized with the Master unit following the chase selected on it including TIME WAIT Pan and...

Page 22: ...n Disconnect mains power before any servicing or maintenance Fuse replacement Locate the fuse which protect the electronics in the base of the unit Using a multimeter test the condition of the fuse re...

Page 23: ...SET DMX CHANNEL 1 Parameter PAN msb DMX CHANNEL 2 Parameter PAN lsb DMX CHANNEL 3 Parameter TILT msb DMX CHANNEL 4 Parameter TILT lsb DMX CHANNEL 5 Parameter SPEED MOVEMENT DMX range Value Mid point D...

Page 24: ...point Move DMX range Mode Option Function range Value DMX value degrees 0 7 Black out 8 255 Proportional dimmer Proportional colour 0 255 degrees Value DMX value range Option DMX range Mid point Mode...

Page 25: ...ure correction 0 2800 K 255 6800 K 156 205 180 Custom White Create RGB levels selectable by DMX 206 255 230 White CTC Channel 12 CTC enabled DMX CHANNEL 13 Parameter COLOUR MACROS DMX range Value Mid...

Page 26: ...1 6 Sec Rainbow Speed 2 15 Sec Rainbow Speed 3 30 Sec Rainbow Speed 4 45 Sec Rainbow Speed 5 60 Sec Rainbow Speed 6 120 Sec Rainbow Speed 7 150 Sec Rainbow Speed 8 180 Sec Please refer to page 14 for...

Page 27: ...X IN 50 cm cable with Neutrik XLR 5 pins Male cable connector on board 1 x DMX OUT 50 cm cable with Neutrik XLR 5 pins Female cable connector on board DELTA 8 R 27 Main AC IN power cord 3 x 1 5 sq mil...

Page 28: ...ic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein D T S Illumina...

Reviews: