SAFETYOFTHE IMPLEMENTATIONOFTHEAUTOMATIONSYSTEM
Before starting the installation, carefully read the entire product installation and operation manual.
Non-observance and non-compliance with the notes in this manual may lead to an accident, resulting in
personal injury or material damage.
The gate drive ensures correct and safe operation only if the installation and use comply with the
following safety rules. DTM System is not responsible for accidents caused by improper use or
unprofessional installation of devices.
The drive has an electronic obstacle detection mechanism. In order to ensure an adequate level of
safety, the adjustment of the force should be performed with particular care.
·
Do not leave packaging materials within the reach of children, as they are potentially dangerous;
·
This product has been designed and manufactured solely for the intended use described in this
documentation. Using it for any other purpose may adversely affect the technical condition and
operation of the device and is a potential source of danger;
·
DTM System is not responsible for the consequences of improper use, inconsistent with the
intended use;
·
The drive must be operated in a dry room;
·
Do not install the device in environments with an increased risk of explosion or containing
aggressive air;
·
If possible, the drive should be mounted at least 2.1 meters above the ground;
·
For a heavy gate, use a second ceiling suspension together with the drive;
·
The half-open gate must remain in this position. If the gate moves up or down, it must be
mechanically adjusted;
·
It is allowed to install the drive moved away from the symmetry axis of the gate, if it does not cause
deformation of the gate itself and allows the gate to move properly in the guides;
·
Automatic swing gates should comply with the standards as well as with any applicable local
regulations, and must also comply with the requirements of EN 12604;
·
DTM System is not responsible for the consequences of design defects of the driven elements or for
their deformation that may occur during use;
·
Walls and ceilings to which the drive will be mounted must be strong and stable;
·
The installation must conform to the requirements of EN 12453. The safety level of the C + D
automated system is required;
·
Before starting any work on the system, disconnect all power sources;
·
The electrical installation to which the automation is connected must comply with the applicable
standards and be properly made;
·
The installer should provide the device with a switch that ensures that the devices are cut off from
the main power supply. The standards require a separation of the contacts of at least 3mm in each
pole (EN 60335-1). It is recommended to use a 6A thermal fuse with a circuit breaker for all circuits;
·
Take care to protect the power circuit with a residual current device;
·
Safety mechanisms (standard EN12978) provide protection against the risks associated with the
movement of moving mechanical parts, such as crushing, snagging or detachment;
·
DTM System is not responsible for the safety and efficient operation of the automation system in
the event of using components that are not products offered by DTMSystem;
·
Only genuine parts should be used for servicing;
·
Do not modify the automation components in any way;
·
The end user should be informed about the method of handling, dealing with failures and about the
dangers of using the automation system
·
During the operation of the automation system, both children and adults must keep a safe distance
from the operating automation;
·
The automation system can only be operated by properly trained adults;
·
Control devices should be kept out of the reach of children in order to protect the automation
system against accidental activation;
·
Movement in the light of the gate is allowed only when it is fully open;
·
The device may only be serviced by qualified personnel;