SAFETYOFTHE IMPLEMENTATIONOFTHEAUTOMATIONSYSTEM

Before starting the installation, carefully read the entire product installation and operation manual.

Non-observance and non-compliance with the notes in this manual may lead to an accident, resulting in
personal injury or material damage.

The gate drive ensures correct and safe operation only if the installation and use comply with the

following safety rules. DTM System is not responsible for accidents caused by improper use or
unprofessional installation of devices.

The drive has an electronic obstacle detection mechanism. In order to ensure an adequate level of

safety, the adjustment of the force should be performed with particular care.

·

Do not leave packaging materials within the reach of children, as they are potentially dangerous;

·

This product has been designed and manufactured solely for the intended use described in this
documentation. Using it for any other purpose may adversely affect the technical condition and
operation of the device and is a potential source of danger;

·

DTM System is not responsible for the consequences of improper use, inconsistent with the
intended use;

·

The drive must be operated in a dry room;

·

Do not install the device in environments with an increased risk of explosion or containing
aggressive air;

·

If possible, the drive should be mounted at least 2.1 meters above the ground;

·

For a heavy gate, use a second ceiling suspension together with the drive;

·

The half-open gate must remain in this position. If the gate moves up or down, it must be
mechanically adjusted;

·

It is allowed to install the drive moved away from the symmetry axis of the gate, if it does not cause
deformation of the gate itself and allows the gate to move properly in the guides;

·

Automatic swing gates should comply with the standards as well as with any applicable local
regulations, and must also comply with the requirements of EN 12604;

·

DTM System is not responsible for the consequences of design defects of the driven elements or for
their deformation that may occur during use;

·

Walls and ceilings to which the drive will be mounted must be strong and stable;

·

The installation must conform to the requirements of EN 12453. The safety level of the C + D
automated system is required;

·

Before starting any work on the system, disconnect all power sources;

·

The electrical installation to which the automation is connected must comply with the applicable
standards and be properly made;

·

The installer should provide the device with a switch that ensures that the devices are cut off from
the main power supply. The standards require a separation of the contacts of at least 3mm in each
pole (EN 60335-1). It is recommended to use a 6A thermal fuse with a circuit breaker for all circuits;

·

Take care to protect the power circuit with a residual current device;

·

Safety mechanisms (standard EN12978) provide protection against the risks associated with the
movement of moving mechanical parts, such as crushing, snagging or detachment;

·

DTM System is not responsible for the safety and efficient operation of the automation system in
the event of using components that are not products offered by DTMSystem;

·

Only genuine parts should be used for servicing;

·

Do not modify the automation components in any way;

·

The end user should be informed about the method of handling, dealing with failures and about the
dangers of using the automation system

·

During the operation of the automation system, both children and adults must keep a safe distance
from the operating automation;

·

The automation system can only be operated by properly trained adults;

·

Control devices should be kept out of the reach of children in order to protect the automation
system against accidental activation;

·

Movement in the light of the gate is allowed only when it is fully open;

·

The device may only be serviced by qualified personnel;

Summary of Contents for GO801/1001

Page 1: ...AUTOMATION SYSTEMS GARAGE DOOR OPENER Assembly manual www dtm pl ENGLISH Version 1 3 GO801 1001 ...

Page 2: ...d comply with the standards as well as with any applicable local regulations andmustalsocomplywiththerequirementsofEN12604 DTMSystemisnotresponsiblefortheconsequencesofdesigndefectsofthedrivenelementsorfor theirdeformationthatmayoccurduringuse Wallsandceilingstowhichthedrivewillbemountedmustbestrongandstable The installation must conform to the requirements of EN 12453 The safety level of the C D ...

Page 3: ...e drive safetysystemandemergencyunlockingfunctionproperly The gate drive cannot be started and continue to operate when there is a wicket in the gate and it is notproperlyclosed Crush or injury protection systems e g photocell systems must work properly after the drive has beenmountedandconnectedtothemains Theradioremotecontrolmayonlybeusedwhenasafeforcevalueisset The radio remote control may only...

Page 4: ...rotect the automation systemagainstaccidentalactivation Movementbetweenthegateleavesisallowedonlywhenitisfullyopen Donotobstructthegatemovement Removeanyobstaclesthatimpedethemovementofthegate Signallampsandinformationboardsmustbeclearlyvisible Manualoperationofthegateispossibleonlywhenthepowersupplyisdisconnectedandthegateis unlocked In the event of a failure disconnect the power release the gate...

Page 5: ... manual 2 MECHANICALASSEMBLY 2 1 Verification of the type and structure of the gate Inordertoproperlycompleteandinstalltheautomationsystem verifythetypeofyourgateandcheck thestructureoftheexistingorinstalledgateintermsoftherequirementspresentedbelow The basic set enables the automation of sectional gates with an ordinary running rail it is recommended to use a boomerang type handle with a double r...

Page 6: ...y specified in the drive parameters must be maintained The gate must operate smoothly and impact free the movement mustbesmoothandunobstructed The drive cannot be used to operate emergency exits or gates on an escaperoute seeescaperoutes If there is a pedestrian door on the powered door a safety switch shall be installed to prevent the automatic system from operating whenthedoorisopen The conditio...

Page 7: ...e help of a spring and a nut Fig 4C Using a suitable wrench tighten the screw until the toothed belt is stretched Referring to Figure 4D mount the drive head to the rail paying attention to the correct positioning of the drive shaft in the toothed belt pulley spline After mounting the drive head you can proceed to install the ceiling hanger as shown in Figs 4E and 4F Other slings can be used if re...

Page 8: ... 20 80 mm above theTHP as shown inFig 5 Drill dependingonthetypeofsubstrate witha10mmdrillinconcreteor5mminwood Fastenthefronthandleofthedrivetothelintelpreparedinthisway Fig 6A 1 sothatthefixingwould ensure a sufficient level of safety expansion bolts anchors etc These activities should be entrusted to a qualifiedpersonwiththenecessaryexperience Then usingthepinandcotterpin connectthefrontofthera...

Page 9: ...stallthemanualbuttonoutsidethedoormovementareainsuchawaythattheoperator is outside the door movement area and the door in operation is always visible The button is mounted essentially 1 6 meters above the ground When laying the control cable avoid running it along the power line that may cause interference in the control signal Fig 6D If there are safety devices in the installation e g photocells ...

Page 10: ...t the gate automation circuitsfrom the Unlocking locking procedure power supply also in the event of a power failure Pull the release cable once The lever will be set vertically and the mechanism will disengage the drive from the trolley allowing the door to move manually Restoring normal operation of the automation pull the unlocking rod again directing the force towards the rear of the drive so ...

Page 11: ...ctly completed warranty card and a short unambiguous description of the damage The cost of disassembly and assembly of the device is borne by the user The warranty does not cover batteries in remote controls any damage r e s u l t i n g f r o m i m p r o p e r u s e unauthorized adjustments alterations and repairs as well as damage caused by lightning overvoltage or short circuit of the power supp...

Page 12: ...10 ...

Reviews: