PWR-DSP3
User Manual
Page 19 of 27
Copyrights DSP4YOU ltd
Filter type provided include:
o
Butterworth (BW): 6/12/18/24/30/36/42/48dB
o
Linkwitz Riley (LR): 12/24/36/48dB
Cut off frequency ranges from 10 to 20kHz in 1Hz increments.
4.2.3.8
Amplifier control
The output control panel gives access to all output controls including:
o
Gain: 0 to -100dB of gain control
o
RMS meter: Shows the dBFS reading inside the DSP
o
Delay: 0 to 9ms
o
Compressor Limiter with controls for Threshold, Ratio, Attack time, Hold time, Release time, Bypass
o
Load monitoring with real time power usage
4.2.4
Audio Video Bridging (AVB) stream configuration
This section applies to PWR-DSP3 enabled with the AVB option. Contact DSP4YOU if you did not purchase the AVB
option and would like to enable it.
While the PWR-DSP3 AVB configuration requires limited setup, the following section will only highlight steps involved in
building/deleting an AVB stream. Please refer to the
AVB primer
for the basic terminology used through out this
section.
4.2.4.1
Build a Stream
Click on the “
Configure AVB Stream
” button to access the following dialog box.
To select one Talker
for configuration,
drag & drop action
as shown by green
arrow
To select one listener
for configuration,
drag & drop action
as shown by green
arrow
Digital Output gain control
Comp/ Limiter metering
Shows amount of attenuation
Output mute
Polarity Invert
Real time power
usage monitoring
Output delay (0-9ms)
Bypass Comp/ Limiter
Comp/ Limiter chart
Typical Comp/Limiter settings