DSC PC5936 Installation Manual Download Page 12

8

3.5 Answering Doorbells

Exterior stations (PC5921/P5922EXT, PC5921/P5922EXT/R) can
be programmed as doorbox 1 or doorbox 2 for doorbell operation.
When someone presses the button on a doorbox 1 station, it will
broadcast a “dingdong” sound over the system. Doorbox 2 will
broadcast a “dong” sound over the system.

To answer the doorbell users can press the Page/Answer button on
any station. The audio channel will operate the same as it does for
a page.

If a page is in progress when a doorbell is pressed the two persons
on the page will hear the tone. To answer the doorbell either per-
son can press the Page/Answer button. The page will end and the
user will immediately be connected to the doorbell station.

3.6 Opening the Door

You can program any intercom station to open the door (using a
doorstrike module) while in communication with a doorbox station.
After answering a doorbell on an intercom station, press and hold
the Page/Answer button for 2 seconds to activate the doorstrike.
The system will sound an acknowledgment beep. The  control panel
will trigger the programmed Command Output (1 - 8), which will
activate the PGM output connected to the doorstrike. 

To terminate communications with the doorbox station, press the
Page/Answer button briefly.

3.7 Doorchime

If the doorchime feature is enabled for zones on the system, when a
zone is violated or restored, the keypads on the partition will beep.

If an Escort5580(TC) v3.0 is connected to the system, it will
announce the label for the zone which generated the doorchime
over the audio stations (NOTE: This feature is only available with
the PC5020/P-8+ v3.1).

3.8 Monitoring

The Monitor feature allows users to listen-in on one area at any
other intercom station (except stations on DND). To listen-in on
an area, go to the station in the area and press and hold the Do Not
Disturb button for two seconds. The station will be put in Do Not
Disturb mode and the Do Not Disturb light will flash. The
PC5936 will transmit all sounds heard from that station to all the
other stations on the system.

Other features such as paging, door answer and answering incom-
ing calls can still be performed and will override the monitor fea-
ture. If a page, door answer or telephone call answer is in progress
the monitor feature will not operate until the conversation is
ended. To turn off the monitor feature press the Do Not Disturb
button once. The red light on the station will stop flashing.

Only one station at a time can be monitored. To monitor another
area, turn the monitor feature off on the first station.

Summary of Contents for PC5936

Page 1: ...NG This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read...

Page 2: ......

Page 3: ...me 8 3 8 Monitoring 8 3 9 Answering Incoming Calls 9 3 10 Transferring and Holding Calls 9 3 11 Call Waiting 9 3 12 User Help Keypad function key 9 3 13 Music Input 10 3 14 Alarm Follower 10 3 15 Verb...

Page 4: ...may not properly alert occupants of a fire for a number of reasons some of which follow The smoke detectors may have been improperly installed or positioned Smoke may not be able to reach the smoke d...

Page 5: ...current draw 65 mA Maximum current draw 100 mA Total current providing capability between AUX terminals 500 mA Input impedance at any microphone input 25k Maximum music input signal level amplitude 2...

Page 6: ...rface module using shielded 22 gauge 4 conductor wire The station can be used to sound the doorbell chime on interior audio stations PC5921EXT R Exterior Audio Station Partner model P5922EXT R The PC5...

Page 7: ...on page 4 Step 4 Wiring the Audio Stations Wire each audio station according to the diagram provided in 2 4 Audio Station Wiring on page 5 Step 5 Wiring the Incoming Telephone Line Wire the incoming t...

Page 8: ...he intercom stations to correct the problem Ventilation In some extreme instances the station may be feeding back to itself The speaker output may be feeding back into the microphone within the housin...

Page 9: ...le or the black terminal of the station make sure the drain wire of the shield does not short anything on the back of the board but not both Refer to the diagram below Avoiding Audio Station Interfere...

Page 10: ...ct the modules to the telephone line as shown below 2 6 Music Input Wiring The music input must be wired to a single port using an audio sig nal which does not exceed 200mV peak to peak To do this con...

Page 11: ...ther person can press the Page Answer button If the PC5936 detects silence for 30 seconds it will end the page 3 2 Page Listens To All You can program the system so that when a page is initiated users...

Page 12: ...communications with the doorbox station press the Page Answer button briefly 3 7 Doorchime If the doorchime feature is enabled for zones on the system when a zone is violated or restored the keypads o...

Page 13: ...has answered a call on an intercom station they can put the call on hold transfer the call to an in house telephone page someone so that they can answer the call at another inter com station To put a...

Page 14: ...e time If both are turned on monitoring will take priority and the music will not be heard 3 14Alarm Follower The audio stations will sound alarm conditions along with the Bell Output of the control p...

Page 15: ...c or Duress alarm occurs the operator will only be able to listen in as the speakers will not be turned on See 4 9 Telephone Ring Options on page 16 for information on pro gramming which events will t...

Page 16: ...ell Tone 666Hz for 592mS sounding on all inte rior intercom ports Intercom Monitor The port is connected to any interior speaker microphone which can send or receive pages This port definition also al...

Page 17: ...ng bell activity OFF Alarm tones will not be sounded 02 Central Station Listen to All Default OFF ON Listen to all zones once on line When talk listen in is initiated the central station will hear act...

Page 18: ...al Alarm NOTE This feature only affects the main panel bell 06 Audio Link Enabled Default OFF ON The audio link will be used instead of the phone line for Audio Help and Verbal Prompts OFF The phone l...

Page 19: ...returns to the state it was in before the zone select function key was pressed 14 Increment Selected Microphone Input if the operator does not hear anything initially they can increment the selected...

Page 20: ...Ref Section 62 Port 1 7 Ref Section 63 Port 8 15 Each Port Intercom Station can be enabled disabled for sounding music Music input needs to be programmed enabled for this to work 4 11Port Function Key...

Page 21: ...itions on page 12 Default 01 I_____I_____I Port 8 Definition 03 I_____I_____I Port 9 Definition 03 I_____I_____I Port 10 Definition 03 I_____I_____I Port 11 Definition 03 I_____I_____I Port 12 Definit...

Page 22: ...22 Port Assignment 00 I_____I_____I Zone 23 Port Assignment 00 I_____I_____I Zone 24 Port Assignment 13 Port Assignments Zones 25 32 Enter the nearest intercom Port Number 01 15 00 Not Used Default 00...

Page 23: ...4 Port Assignment 00 I_____I_____I Zone 55 Port Assignment 00 I_____I_____I Zone 56 Port Assignment 17 Port Assignments Zones 57 64 Enter the nearest intercom Port Number 01 15 00 Not Used Default 00...

Page 24: ...5 Incoming Sounds on Port 12 Enabled Disabled ON I_____I 6 Incoming Sounds on Port 13 Enabled Disabled ON I_____I 7 Incoming Sounds on Port 14 Enabled Disabled ON I_____I 8 Incoming Sounds on Port 15...

Page 25: ..._I_____I Mode Key 2 Key 00 I_____I_____I Mode Key 3 Key 00 I_____I_____I Mode Key 4 Key 00 I_____I_____I Mode Key 5 Key 00 I_____I_____I Mode Key 6 Key 00 I_____I_____I Mode Key 7 Key 00 I_____I_____I...

Page 26: ...Enabled Disabled OFF I_____I 8 Port 7 Telephone Ring Enabled Disabled 61 Telephone Ring Mask Two Default Option ON OFF OFF I_____I 1 Port 8 Telephone Ring Enabled Disabled OFF I_____I 2 Port 9 Teleph...

Page 27: ...Port 5 Enabled to Activate Doorstrike Disabled OFF I_____I 7 Port 6 Enabled to Activate Doorstrike Disabled OFF I_____I 8 Port 7 Enabled to Activate Doorstrike Disabled 71 Doorstrike Activation Mask...

Page 28: ...24 NOTES...

Page 29: ...ns to the telephone network shall be made through standard plugs and telephone com pany provided jacks or equivalent in such a man ner as to allow for easy immediate disconnection of the terminal equi...

Page 30: ...attempts will be limited to a replacement of the product as the exclusive remedy for breach of warranty Under no circum stances shall Digital Security Controls Ltd be liable for any special incidental...

Page 31: ......

Page 32: ...tif terminal indique pour viter toute sur charge le pourcentage de la charge totale qui peut tre raccord e un circuit t l phonique boucl utilis par ce dispositif La terminaison du circuit boucl peut t...

Reviews: