8
4.3 Enable Supervision of Wireless Zones
NOTE:
(for PC501X v1.x control panels only) In order for wireless zones to be
supervised, you must enable Double End of Line (DEOL) supervision in the
PC5015 control panel. For more information, refer to your Installation Manual.
NOTE:
(PC501X, PC5008, PC1565, PC585 v2.0 and higher only) For wireless
supervision to work, you must enable the wireless zone attribute on all wireless
zones (sections [101] to [132], option [8] ON).
Wireless Supervisory Window
Each wireless zone will send a supervisory signal every 12 minutes. If the
receiver does not receive a signal within the time programmed for the
Wireless
Supervisory Window
, it will generate a supervisory fault.
To program the wireless supervisory window:
1. Enter [
✱
][8][Installer Code] to enter Installer Programming.
2. Enter [804] to enter the PC5132 Module Programming.
3. Enter section [81].
4. Enter the time period for the supervisory window. The window is
programmed in 15 minute increments. The default programming is 10
(x15minutes), which is equal to 150minutes (2.5 hours). Valid entries are
(04) - (96), equal to 1 - 24 hours.
5. To exit press [#].
Disable/Enable Zone Supervision
All wireless zones have supervision enabled by default. To disable supervision
for any zone, enter the following at any system keypad:
1. Enter [
✱
][8][Installer Code] to enter Installer Programming.
2. Enter [804] to enter the PC5132 Module Programming.
3. Enter sections [82], [83], [84] and [85]. Enable or disable supervision for
each wireless zone by turning each relevant option on or off.
4. To exit press [#].
4.4 Jamming Signal Detection
The PC5132 receiver detects jamming signals that can prevent the receiver from
properly receiving transmissions from enrolled devices. When jamming signals
are detected for 5 seconds, the control panel will generate a General System
Tamper trouble, which will be reported immediately. Jamming signal detection
is turned ON by default.
To turn OFF jamming signal detection:
1. Enter [
✱
][8][Installer Code] to enter Installer Programming.
2. Enter [804] to enter the PC5132 Module Programming.
3.
Turn ON section [90], option [7].
4. To exit press [#].
O T H E R P R O G R A M M I N G