![DSC PC5020 Power864 Installation Manual Download Page 49](http://html1.mh-extra.com/html/dsc/pc5020-power864/pc5020-power864_installation-manual_2534695049.webp)
P r o g r a m m i n g S e c t i o n s :
5 . 1 0 M o d u l e P r o g r a m m i n g P W S S e c t 1 0
43
[703] - Delay Between Dialing Attempts
For standard (force) dialing, the panel will go off-hook,
search for dial tone for 5 seconds, hang-up for 20 seconds,
go off-hook, search for dial tone for 5 seconds, then dial. If
there is no initial handshake recognized within 40 sec-
onds, the panel will hang up. This programmable timer
adds a delay before the next call is attempted, and is
defaulted to 001 for a total of six seconds.
5.10 Module Programming PWS Sect 10
The programming sections listed below pertain to addi-
tional modules on the system. For instructions on program-
ming these modules and a description of each programming
section, see the associated
Installation Manual
s.
3
Arming Inhibit
ON
AC/DC Arming Inhibit with Battery Check Enabled.
When an AC or DC Trouble is present,
the system will not arm. This includes Keypad, Keyswitch, Automatic, and Downloading arming.
If enabled and arming is attempted, the system will perform a system battery check as well as a
battery check on all peripheral modules supported by a backup battery.
OFF
Arming not Inhibited
. The system can be armed, regardless of the presence of an AC or DC
Trouble and will not check all system batteries upon arming.
NOTE: If this option is enabled, it is strongly recommended that AC Troubles be dis-
played (Section [017], Option 1 ON).
4
Latching System Tamper
ON
System Tampers Require Installer Reset and Inhibit Arming
If any system Tamper condition
occurs, the Installer Code must be entered [*][8] [Installer Code] and the Tamper condition must
be restored before the system can be armed. This includes Auto-arming and keyswitch. If Auto-
arming is attempted with a latched tamper, the panel will not arm. The Auto-arm cancellation
code is not transmitted however because a user did not cancel the Auto-arming sequence.
OFF
System Tampers Do Not Require Installer Reset.
If enabled, the manual bypassing of a
zone will not bypass the tamper or fault states (DEOL). This feature also applies to Zone Faults.
5
Access Code Length
ON
6-digit Access Codes
. All access codes on the system will be 6 digits in length except the Panel
I.D. Code and the Downloading Access Code.
• System Master Code = XXXX56 XXXX = previous code, (1234)
• Installer Code = YYYY55 YYYY = previous code, (5555)
OFF
4-digit Access Codes
. All access codes on the system will be 4 digits in length. For any existing
codes, the last 2 digits are removed.
6
Busy Tone
ON
Busy Tone Detection Enabled.
If these tones are detected, the communicator will disengage
the phone line and try to place the call again following the Delay Between Dialing Attempts.
OFF
Busy Tone Detection Disabled.
The communicator will use the standard dialing procedure for
every attempt.
7
Battery Current Charge
ON
High Current Battery Charge.
Approximately 650-700 mA.
OFF
Standard Current Battery Charge.
Approximately 350 mA.
8
ON
For Future Use
[701] FIRST INTERNATIONAL OPTION CODES
Option
International Code
On/Off
Description
[702] SECOND INTERNATIONAL OPTION CODES
Option
International Code
On/Off
Description
1
Pulse Dial
ON
Pulse Dialing Make/Break Ratio is 33/67
OFF
Pulse Dialing Make/Break Ratio is 40/60
2
Force Dial
ON
Force Dialing Enabled.
If the first attempt by the panel to call the monitoring station fails to
detect a dial tone, on every subsequent attempt the panel will dial regardless of the presence of
dial tone. See {703] Delay Between Dialing Attempts
OFF
Force Dialing Disabled.
The panel will not dial the programmed telephone number if dial tone
is not present.
3
Land Line Test Transmission
ON
Land Line Test Transmission Interval is in Minutes
. The value programmed in Section [370]
seventh entry is in minutes.
OFF
Land Line Test Transmission Interval is in Days.
The value programmed in Section [370] Sev-
enth entry is in days.
NOTE:
This option must be OFF for the PC5020CF.
4
Handshake
ON
1600 Hz Handshake.
The communicator responds to a 1600 Hz handshake for bps formats.
OFF
Standard Handshake.
The communicator responds to the handshake designated by the for-
mat selected (1400 or 2300 Hz).
5
I.D. Tone
ON
I.D. Tone Enabled.
After the telephone number is dialed, the panel will emit a tone (as speci-
fied by Option 6) for 500ms every 2 seconds to indicate that it is a digital equipment call, not
voice.
OFF
I.D. Tone Disabled.
6
I.D. Tone Frequency
ON
2100 Hz I.D. Tone
OFF
1300 Hz I.D. Tone
7
DLS Window
ON
One Time 1-hour User-enabled DLS Window.
The user-enabled DLS Window is 1 hour in
length and will be closed after a successful hang-up from a downloading call.
OFF
Full 6-hour User-enabled DLS Window.
The user-enabled DLS Window is 6 hours in length
and remains open after a successful hang-up from a downloading call. This option determines
the length of the DLS window available on power up.
8
FTC Bell
ON
Bell on FTC when armed.
If a Failure to Communicate Trouble is generated while the system is
armed, the Bell output will sound for the length of Bell time-out or until the system is disarmed.
OFF
FTC Trouble only when armed.
If a Failure to Communicate Trouble is generated while the
panel is armed, the Bell output will not sound but the keypad buzzer will sound Trouble beeps
until a key is pressed.
Summary of Contents for PC5020 Power864