WARNING 

Please Read Carefully

Note to Installers

This warning contains vital information. As the only individual in
contact with system users, it is your responsibility to bring each
item in this warning to the attention of the users of this system.

System Failures

This system has been carefully designed to be as effective as
possible. There are circumstances, however, involving fire, bur-
glary, or other types of emergencies where it may not provide
protection. Any alarm system of any type may be compromised
deliberately or may fail to operate as expected for a variety of
reasons. Some but not all of these reasons may be:

■ 

Inadequate Installation

A security system must be installed properly in order to provide
adequate protection. Every installation should be evaluated by a
security professional to ensure that all access points and areas
are covered. Locks and latches on windows and doors must be
secure and operate as intended. Windows, doors, walls, ceilings
and other building materials must be of sufficient strength and
construction to provide the level of protection expected. A
reevaluation must be done during and after any construction
activity. An evaluation by the fire and/or police department is
highly recommended if this service is available.

 Criminal Knowledge

This system contains security features which were known to be
effective at the time of manufacture. It is possible for persons
with criminal intent to develop techniques which reduce the
effectiveness of these features. It is important that a security
system be reviewed periodically to ensure that its features
remain effective and that it be updated or replaced if it is found
that it does not provide the protection expected.

 Access by Intruders

Intruders may enter through an unprotected access point, cir-
cumvent a sensing device, evade detection by moving through
an area of insufficient coverage, disconnect a warning device,
or interfere with or prevent the proper operation of the system.

 Power Failure

Control units, intrusion detectors, smoke detectors and many
other security devices require an adequate power supply for
proper operation. If a device operates from batteries, it is possi-
ble for the batteries to fail. Even if the batteries have not failed,
they must be charged, in good condition and installed correctly.
If a device operates only by AC power, any interruption, how-
ever brief, will render that device inoperative while it does not
have power. Power interruptions of any length are often accom-
panied by voltage fluctuations which may damage electronic
equipment such as a security system. After a power interruption
has occurred, immediately conduct a complete system test to
ensure that the system operates as intended.

 Failure of Replaceable Batteries

This system’s wireless transmitters have been designed to pro-
vide several years of battery life under normal conditions. The
expected battery life is a function of the device environment,
usage and type. Ambient conditions such as high humidity,
high or low temperatures, or large temperature fluctuations may
reduce the expected battery life. While each transmitting device
has a low battery monitor which identifies when the batteries
need to be replaced, this monitor may fail to operate as
expected. Regular testing and maintenance will keep the system
in good operating condition.

 Compromise of Radio Frequency (Wire-

less) Devices

Signals may not reach the receiver under all circumstances
which could include metal objects placed on or near the radio
path or deliberate jamming or other inadvertent radio signal
interference.

 System Users

A user may not be able to operate a panic or emergency switch
possibly due to permanent or temporary physical disability,
inability to reach the device in time, or unfamiliarity with the
correct operation. It is important that all system users be trained
in the correct operation of the alarm system and that they know
how to respond when the system indicates an alarm.

 Smoke Detectors

Smoke detectors that are a part of this system may not properly
alert occupants of a fire for a number of reasons, some of which
follow. The smoke detectors may have been improperly

installed or positioned. Smoke may not be able to reach the
smoke detectors, such as when the fire is in a chimney, walls or
roofs, or on the other side of closed doors. Smoke detectors
may not detect smoke from fires on another level of the resi-
dence or building.
Every fire is different in the amount of smoke produced and the
rate of burning. Smoke detectors cannot sense all types of fires
equally well. Smoke detectors may not provide timely warning
of fires caused by carelessness or safety hazards such as smok-
ing in bed, violent explosions, escaping gas, improper storage
of flammable materials, overloaded electrical circuits, children
playing with matches or arson.
Even if the smoke detector operates as intended, there may be
circumstances when there is insufficient warning to allow all
occupants to escape in time to avoid injury or death.

 Motion Detectors

Motion detectors can only detect motion within the designated
areas as shown in their respective installation instructions. They
cannot discriminate between intruders and intended occupants.
Motion detectors do not provide volumetric area protection.
They have multiple beams of detection and motion can only be
detected in unobstructed areas covered by these beams. They
cannot detect motion which occurs behind walls, ceilings, floor,
closed doors, glass partitions, glass doors or windows. Any type
of tampering whether intentional or unintentional such as
masking, painting, or spraying of any material on the lenses,
mirrors, windows or any other part of the detection system will
impair its proper operation.
Passive infrared motion detectors operate by sensing changes in
temperature. However their effectiveness can be reduced when
the ambient temperature rises near or above body temperature
or if there are intentional or unintentional sources of heat in or
near the detection area. Some of these heat sources could be
heaters, radiators, stoves, barbeques, fireplaces, sunlight, steam
vents, lighting and so on.

 Warning Devices 

Warning devices such as sirens, bells, horns, or strobes may not
warn people or waken someone sleeping if there is an interven-
ing wall or door. If warning devices are located on a different
level of the residence or premise, then it is less likely that the
occupants will be alerted or awakened. Audible warning
devices may be interfered with by other noise sources such as
stereos, radios, televisions, air conditioners or other appliances,
or passing traffic. Audible warning devices, however loud, may
not be heard by a hearing-impaired person.

 Telephone Lines

If telephone lines are used to transmit alarms, they may be out
of service or busy for certain periods of time. Also an intruder
may cut the telephone line or defeat its operation by more
sophisticated means which may be difficult to detect.

 Insufficient Time

There may be circumstances when the system will operate as
intended, yet the occupants will not be protected from the emer-
gency due to their inability to respond to the warnings in a
timely manner. If the system is monitored, the response may
not occur in time to protect the occupants or their belongings.

 Component Failure

Although every effort has been made to make this system as
reliable as possible, the system may fail to function as intended
due to the failure of a component.

 Inadequate Testing

Most problems that would prevent an alarm system from operat-
ing as intended can be found by regular testing and maintenance.
The complete system should be tested weekly and immediately
after a break-in, an attempted break-in, a fire, a storm, an earth-
quake, an accident, or any kind of construction activity inside or
outside the premises. The testing should include all sensing
devices, keypads, consoles, alarm indicating devices and any
other operational devices that are part of the system.

 Security and Insurance

Regardless of its capabilities, an alarm system is not a substi-
tute for property or life insurance. An alarm system also is not
a substitute for property owners, renters, or other occupants to
act prudently to prevent or minimize the harmful effects of an
emergency situation.

firealarmresources.com

Summary of Contents for PC4936

Page 1: ...al WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read firealarmresources com ...

Page 2: ...ited to a replacement of the product as the exclusive remedy for breach of warranty Under no circum stances shall Digital Security Controls Ltd be liable for any special incidental or consequential damages based upon breach of warranty breach of contract negligence strict liability or any other legal theory Such damages include but are not lim ited to loss of profits loss of the product or any ass...

Page 3: ...roperly alert occupants of a fire for a number of reasons some of which follow The smoke detectors may have been improperly installed or positioned Smoke may not be able to reach the smoke detectors such as when the fire is in a chimney walls or roofs or on the other side of closed doors Smoke detectors may not detect smoke from fires on another level of the resi dence or building Every fire is di...

Page 4: ... 9 Answering Incoming Calls 8 3 10 Transferring and Holding Calls 9 3 11 Call Waiting 9 3 12 User Help Keypad function key 9 3 13 Music Input 9 3 14 Alarm Follower 10 3 15 Verbal Alarm Announcements 10 3 16 Central Station Talk Listen in 10 Section 4 Programming 11 4 1 Port Definitions 11 4 2 Audio Station Options 11 4 3 Doorstrike Function Button 11 4 4 Page Listens To All 12 4 5 Handsfree Doorbe...

Page 5: ...output follower PC4937 Eight Port Expansion Module Current draw 5 mA Connect up to 8 audio stations interior or exterior Total current providing capability between AUX terminals 500 mA Input impedance at any microphone input 25kΩ Maximum music input signal level amplitude 200 mV peak to peak PC5921 Interior Audio Station Standby current draw 20 mA Maximum current draw 50 mA Built in speaker and mi...

Page 6: ...C5921EXT R Exterior Audio Station The PC5921EXT R Exterior Audio Station is housed in a gray fade resistant case designed for outside use Each station has a separate microphone and speaker Each station must be home run to the interface module using shielded 22 gauge 4 conductor wire The station can be used to sound the doorbell chime on interior audio stations A relay is included so that a pre exi...

Page 7: ...e control panel as the PC4936 must be con nected to the incoming telephone line Before attaching the cabinet to the wall make sure to press the nylon circuit board mounting studs into the cab inet from the back Step 2 Connecting the PC4937 Module optional To add 8 ports to the system connect the PC4937 to the PC4936 module See the PC4937 Installation Sheet for instructions Step 3 Wiring the Combus...

Page 8: ...ing either of these con trols counter clockwise will reduce their gain thereby reducing the possi ble level of feedback Placement Avoid installing intercom stations directly across from one another Feedback may also occur due to room acoustics which will be affected by several different factors such as the size of the room whether or not the floor is carpeted and the objects in the room Try moving...

Page 9: ...ack terminal of the station make sure the drain wire of the shield does not short anything on the back of the board but not both Refer to the diagram below Avoiding Audio Station Interference Noise The Combus wiring and several different electrical devices fluorescent lighting etc may induce noise onto the intercom wires For this reason shielded wire should be used whenever possible If shielded wi...

Page 10: ...phone line as shown below 2 5 Music Input Wiring The music input must be wired to a single port using an audio signal which does not exceed 200mV peak to peak To do this connect the music source to the microphone input for a port connect one side of the source to the microphone input one of terminals M1 to M7 or M8 to M15 if a PC4937 is used connect the other side to a COM terminal Program the por...

Page 11: ...either person can press the Page Answer button If the PC4936 detects silence for 30 seconds it will end the page 3 2 Page Listens To All You can program the system so that when a page is initiated users at all other intercom stations can respond hands free for 30 seconds i e without pressing the Page Answer button Ports in DND mode or which have the Paging Monitoring Doorbell Sounds option turned ...

Page 12: ... Chime If the door chime feature is enabled for zones on the system when a zone is violated or restored the keypads on the partition will beep If an Escort4580 v1 3 is connected to the system it will announce the label for the zone which generated the door chime over the audio stations 3 8 Monitoring The Monitor feature allows users to listen in on one area at any other inter com station except st...

Page 13: ... as usual To pick up a holding call at a telephone go to the telephone pick up the receiver and press the key for 1 second This puts the call through to the telephone and disconnects the intercom station from the conversation To pick up a holding call at any intercom station press the Do Not Disturb button 3 11Call Waiting If you have answered the telephone through an audio station and a second ca...

Page 14: ...ccurs the PC4936 will seize the telephone line call the central station and initiate a talk listen in session The PC4936 will start a session of low gain listen in on the station closest to the zone in alarm or on all stations if the CS Listen All option is on see 4 9 Central Station Talk Listen In on page 13 When the central station operator presses any key on the telephone a new session will beg...

Page 15: ...sable certain features of each interior audio station using the fol lowing toggle options All options are turned on for each station by default Pag Mon Drbell When you turn this option off pages doorbell sounds and monitoring will not be broadcast to the station Incoming Rings When you turn this option off incoming telephone calls will not ring at the station Doorstrike When you turn this option o...

Page 16: ...larms are silenced You can program two options on the PC4936 to customize the verbal alarm Alarm Tone Time Ref 001602 Program the length of time the alarm tone will sound before the zone label is announced Default is 015 valid entries are 000 255 seconds If programmed for 000 no alarm tone will sound Bells Active During Verbal Alarm Ref 001601 If the Bel Verbal Alm toggle option is on the system b...

Page 17: ... are enabled you should also enable the Duress Alarm option NOTE In all cases a reporting code for the event must be programmed in the control panel For example if a reporting code for a zone alarm is not programmed an alarm in the zone will not initiate a Talk Listen In session NOTE Module tampers will not initiate a Talk Listen in session For Talk Listen in to work correctly on zone alarms you m...

Page 18: ...e telephone Additional commands can be programmed as Mode Keys which are two button entries on the Touch Tone telephone The central station may be using other Talk Listen In equipment You can program the PC4936 so that central station operators can use the same com mands for all equipment Ask your central station how they need the com mand keys to be programmed The following commands are available...

Page 19: ...03 Port 14 I_____I_____I 00 Port 15 I_____I_____I 00 001600XX01 Audio Port Options XX Port number 01 15 See section 4 2 Audio Station Options on page 11 Paging Monitor Incoming Doorstrike Doorbell Rings Default Y N N Port 01 I_________I I_________I I_________I 02 I_________I I_________I I_________I 03 I_________I I_________I I_________I 04 I_________I I_________I I_________I 05 I_________I I______...

Page 20: ..._____I Port 15 I_____I_____I PC4936 Programming 001601 Audio Toggle Options See sections 4 4 Page Listens To All 4 5 Handsfree Doorbell Answer 4 6 Verbal Alarm Options 4 9 Central Station Talk Listen In Default CS Listen All N I_________I Page Listn All N I_________I Hands Free Dr N I_________I Bel Verbal Alm N I_________I Zone Alarms Y I_________I Misc Alarms Y I_________I Tampers N I_________I O...

Page 21: ..._____I_____I 015 I_____I_____I 048 I_____I_____I 081 I_____I_____I 114 I_____I_____I 016 I_____I_____I 049 I_____I_____I 082 I_____I_____I 115 I_____I_____I 017 I_____I_____I 050 I_____I_____I 083 I_____I_____I 116 I_____I_____I 018 I_____I_____I 051 I_____I_____I 084 I_____I_____I 117 I_____I_____I 019 I_____I_____I 052 I_____I_____I 085 I_____I_____I 118 I_____I_____I 020 I_____I_____I 053 I____...

Page 22: ...ct your cen tral station to determine which functions to program Program unused keys as 00 Key Key Default Key Key Default 00 0 00 I_____I_____I 00 Mode 0 00 I_____I_____I 01 1 01 I_____I_____I 01 Mode 1 00 I_____I_____I 02 2 00 I_____I_____I 02 Mode 2 00 I_____I_____I 03 3 03 I_____I_____I 03 Mode 3 00 I_____I_____I 04 4 14 I_____I_____I 04 Mode 4 00 I_____I_____I 05 5 15 I_____I_____I 05 Mode 5 ...

Page 23: ...he terminal equipment Stan dard jacks shall be so arranged that if the plug connected thereto is withdrawn no interference to the operation of the equipment at the customer s premises which remains connected to the telephone network shall occur by reason of such withdrawal INCIDENCE OF HARM Should terminal equipment or protective circuitry cause harm to the telephone network the telephone company ...

Page 24: ...honique bouclé utilisé par ce dispositif La terminaison du circuit bouclé peut être constituée de n importe quelle combinaison de dis positifs pourvu que la somme des indices de charge de l ensemble des dispositifs ne dépasse pas 100 L Indice de charge de ce produit est 0 1B NOTICE The Industry Canada label identifies cer tified equipment This certification means that the equipment meets certain t...

Reviews: