Trouble Conditions

Zone Light

Trouble

1

Low Battery

2

Mains AC Power

3

Keypad Tamper

4

Telephone Line

5

Unsuccessful

Communication

6

Bell Circuit

7

Smoke Detector Circuit

8

Reset Clock

When finished viewing troubles, press the [#] key.

Trouble

Armed

Ready

Memory

Bypass

Fire

Program

F

A

P

Press [#]:

• when an error is made in entering an Access

Code, then enter the code again

• to return to “Ready” after using [

] commands

[F] Key:

Press and hold this key for 2 seconds to
sound an [F] Key alarm

[A] Key:

Press and hold this key for 2 seconds to
generate an [A] Key alarm

[P] Key:

Press and hold this key for 2 seconds to
generate a [P] Key alarm.

These keys must be enabled by your Installer

before they become functional.  Your Installer

will tell you how these keys operate on your

system.

Disarming the System with the LCD600 Keypad

Enter the premises through the Entry-Exit Zone and go to the keypad.  The
message shown here will be displayed.  Enter an Access Code before the
Entry Delay expires.

This message will be displayed to indicate that the system has been
disarmed, and that there were no alarms or trouble conditions during the
time the system was armed.  This message will be displayed for 5 seconds.

After 5 seconds, this message will be displayed.

If there is a Trouble Condition Present:

This message will be displayed if there is a trouble condition present.  Refer
to Displaying Trouble Conditions for instructions on how to display and
correct trouble conditions.

If there was an Alarm:

If a one or more zones went into alarm while the system was armed, a
message similar to the one shown here will be displayed.  Use the [<] and
[>] Keys to scroll through the list of zones that went into alarm.

After viewing the zones that went into alarm, this message will be displayed
if there are still unsecured zones on the system.  Use the [<] and [>] Keys
to scroll through the list of open zones.

Resetting Smoke Detectors with the LCD600 Keypad

If the Fire Alarm sounds at night, do not investigate the alarm: follow your evacuation plan immediately.
Go to a neighbour and call the fire brigade.

Smoke detectors installed on your system may be reset after a false alarm using the [

][4] command. To reset

smoke detectors to normal,  first clear all products of combustion from the detectors.

Press the [

] Key to enter the User Functions List.  Use the [>] Key to scroll

to the message shown here.

Press and hold down the [4] Key for several seconds.  If the detectors are clear of smoke, they will return to
normal.  If the detectors still have smoke in them, the alarm will sound again.  If the alarm sounds again, first
ensure that there is no threat of fire; you may then silence the alarm and reset the smoke detectors.

18

Summary of Contents for PC2580

Page 1: ...and not to damage incurred in shipping or handling or damage due to causes beyond the control of Digital Security Controls Ltd such as lightning excessive voltage mechanical shock water damage or damage arising out of abuse alteration or improper application of the equipment The foregoing warranty shall apply only to the original buyer and is and shall be in lieu of any and all other warranties wh...

Page 2: ...ed and followed 1 Every family member should participate in developing the escape plan 2 Study the possible escape routes from each location within the house Since many fires occur at night special attention should be given to the escape routes from sleeping quarters 3 It is essential that escape from a bedroom be possible without opening the interior door Consider the following when making your e...

Page 3: ...he bell or siren and the keypad sounder will sound for 2 seconds When the test is complete press the Key to return to the Ready mode Testing Your System with the LCD600 Keypad It is recommended that you test your system regularly NOTE Perform system tests in the off peak hours such as early morning or late evening 1 Call to inform your monitoring station that you are testing your system 2 Disarm t...

Page 4: ...message is displayed enter the new Access Code Use only the numbers from 0 to 9 do not press or when entering the code To completely erase a code enter Do not try to erase the Master Code Access Code 1 When the Access Code is programmed a message similar to the one shown here will be displayed In this example the message indicates that Access Code 3 has been programmed If is entered to erase a cod...

Page 5: ... system and to bypass zones Each person should keep their 4 digit Access Code secret to ensure system security Entry Delay The Entry Delay is the period of time allowed for someone to enter the premises and disarm the system Exit Delay The Exit Delay is the period of time allowed for someone to leave the premises after they have entered an Access Code to arm the system Entry Exit Door or Zone The ...

Page 6: ...d When finished bypassing zones press the Key to return the keypad to the Ready mode Note that bypasses are automatically removed when the system is disarmed PC2550RK AND LED625 KEYPADS Important Test your system regularly Follow the guidelines for correcting system trouble conditions have any system trouble conditions you cannot correct yourself attended to by your installer F A P R e a d y A r m...

Page 7: ...yed If there is a Trouble Condition Present This message will be displayed if there is a trouble condition present Refer to Displaying Trouble Conditions for instructions on how to display and correct trouble conditions If there was an Alarm If a one or more zones went into alarm while the system was armed a message similar to the one shown here will be displayed Use the and Keys to scroll through...

Page 8: ...etector is reset but goes into alarm again after the 90 second delay the fire alarm will sound again and the process described above will repeat A fire alarm will be transmitted to your monitoring station after 30 seconds if it is not silenced by pressing the Key Smoke detectors installed on your system may be reset after a false alarm using the 4 command To reset smoke detectors to normal first c...

Page 9: ...ccurs and your system is set for Engineer Reset you must call your alarm company to reset the system before it can be re armed In this instance the memory light will remain ON until reset by the installer Bypassing Zones A bypassed zone will not cause an alarm Zones may be bypassed to allow access to part of the protected area while other zones are armed For example bypassing the zone protecting y...

Page 10: ...he keypad The LCD600 Keypad will display messages when using the Bell Test command Refer to Page 22 for instructions on performing a Bell Test with the LCD600 Keypad Weekly Testing It is recommended that you test your system regularly NOTE Perform system tests in the off peak hours such as early morning or late evening 1 Call to inform your monitoring station that you are testing your system 2 Dis...

Page 11: ...d to allow someone to arm the system without that person having to be provided with an Access Code When 0 is entered the Exit Delay will begin and the user may leave the premises through the Entry Exit door At the end of the Exit Delay the Armed light will come ON and the system will be fully armed To turn the Quick Arm feature ON and OFF enter 6 Master Code 4 If Quick Arm is being turned ON the k...

Page 12: ...esent For Mains AC Failure the Trouble light will come ON as soon as the mains fails and will remain ON until power is restored LCD6OO 13 LCD6OO CHANGING SYSTEM FEATURES Changing Access Codes The PC2580 features 16 programmable Access Codes The first code is the Master Code and the remaining 15 codes are normal Access Codes Programming Access Codes Enter 5 Master Code the Program light will FLASH ...

Page 13: ...pproval of the apparatus if as a result it then ceases to comply with the standards against which approval was granted This apparatus has been approved for connection to the Public Switched Telephone Network PSTN including BT Kingston Upon Hull and Mercury This apparatus is not suitable for use as an extension to a payphone Only the network operator or a person authorised by the network operator i...

Reviews: