DSC PC2580 Instruction Manual Download Page 3

3

SYSTEM INFORMATION

Installer

___________________________________________________________________________________

Phone

________________________________

Installation Date ____________________________

Monitoring Station: _________________________

Telephone Number: _________________________

Account Number ___________________________

CONTACTS

Name

________________________________

Phone ________________________

Name

________________________________

Phone ________________________

Name

________________________________

Phone ________________________

ZONE INFORMATION

Zone

Type

Protected Area

1

____________________

_______________________________________________________

2

____________________

_______________________________________________________

3

____________________

_______________________________________________________

4

____________________

_______________________________________________________

5

____________________

_______________________________________________________

6

____________________

_______________________________________________________

7

____________________

_______________________________________________________

8

____________________

_______________________________________________________

Entrance Delay ____________________________

Exit Delay __________________________________

Auxiliary Entrance Delay ____________________

Auxiliary Exit Delay __________________________

SPECIAL FEATURES

[F] Key

 Enabled

 Disabled

[A] Key

 Enabled

 Disabled

[P] Key

 Enabled

 Disabled

KEYPADS

The following keypads are installed on your system:

________

PC2550RK Keypads

________

LED625 Keypads

________

LCD600 Message Display Keypads

22

Bell Test

With the system disarmed, press the [

] Key.

Use the [<] and [>] Keys to scroll to this message.  Press [6], then enter the
Master Code.

Use the [<] and [>] Keys to scroll to this message.  Press [8] to turn perform
a Bell Test.  When the Bell Test is selected, the bell or siren and the keypad
sounder will sound for 2 seconds.  When the test is complete, press the [#]
Key to return to the “Ready” mode.

Testing Your System with the LCD600 Keypad

It is recommended that you test your system regularly.  

NOTE:

     Perform system tests in the off-peak hours,

such as early morning or late evening.

1

Call to inform your monitoring station that you are testing your system.

2

Disarm the system and ensure that this message is displayed.

3

Perform a Bell Test by entering [

][6][Master Code][8]; the message

shown here will be displayed.  If a trouble condition is indicated after
the test, press [

][2] to view the trouble condition.  Press [#] when

finished viewing trouble conditions.

4

Activate each sensor on your system one at a time.  For example, open protected doors and windows,
and walk in areas protected by motion detectors.

As each zone is activated, this message will be displayed.  Use the [<] and
[>] Keys to scroll through the list of open zones.  If you are opening zones
one at a time, only one zone should be displayed as being open.

When the [<] or [>] Key is pressed, a message similar to this will be
displayed to indicate which zone has been activated.

When the zone is closed, and if all zones are closed, this message will be
displayed.  Continue to activate the rest of the zones on your system and
ensure that the keypad indicates when each zone is opened and closed.

5

If they are programmed for operation, press the [F], [A], and [P] keys in turn. The [F] Key will sound the
bell or siren in a pulsed mode.  Enter an Access Code to silence the alarm.  The [A] Key is a silent
alarm; the [P] Key may be programmed as silent or audible.  If an alarm sounds, enter an Access
Code to silence the alarm.

6

If your system has a Fire Zone, activating the Fire Zone will cause the bell or siren to sound with a
pulsed tone.  

CAUTION: Do not use an open flame or burning materials to test a smoke detector.

Contact your installer for information on safe methods to activate a smoke detector.

7

Should the system fail to operate properly, call your alarm dealer for service.

8

When testing is complete, call and advise the monitoring station.

Summary of Contents for PC2580

Page 1: ...and not to damage incurred in shipping or handling or damage due to causes beyond the control of Digital Security Controls Ltd such as lightning excessive voltage mechanical shock water damage or damage arising out of abuse alteration or improper application of the equipment The foregoing warranty shall apply only to the original buyer and is and shall be in lieu of any and all other warranties wh...

Page 2: ...ed and followed 1 Every family member should participate in developing the escape plan 2 Study the possible escape routes from each location within the house Since many fires occur at night special attention should be given to the escape routes from sleeping quarters 3 It is essential that escape from a bedroom be possible without opening the interior door Consider the following when making your e...

Page 3: ...he bell or siren and the keypad sounder will sound for 2 seconds When the test is complete press the Key to return to the Ready mode Testing Your System with the LCD600 Keypad It is recommended that you test your system regularly NOTE Perform system tests in the off peak hours such as early morning or late evening 1 Call to inform your monitoring station that you are testing your system 2 Disarm t...

Page 4: ...message is displayed enter the new Access Code Use only the numbers from 0 to 9 do not press or when entering the code To completely erase a code enter Do not try to erase the Master Code Access Code 1 When the Access Code is programmed a message similar to the one shown here will be displayed In this example the message indicates that Access Code 3 has been programmed If is entered to erase a cod...

Page 5: ... system and to bypass zones Each person should keep their 4 digit Access Code secret to ensure system security Entry Delay The Entry Delay is the period of time allowed for someone to enter the premises and disarm the system Exit Delay The Exit Delay is the period of time allowed for someone to leave the premises after they have entered an Access Code to arm the system Entry Exit Door or Zone The ...

Page 6: ...d When finished bypassing zones press the Key to return the keypad to the Ready mode Note that bypasses are automatically removed when the system is disarmed PC2550RK AND LED625 KEYPADS Important Test your system regularly Follow the guidelines for correcting system trouble conditions have any system trouble conditions you cannot correct yourself attended to by your installer F A P R e a d y A r m...

Page 7: ...yed If there is a Trouble Condition Present This message will be displayed if there is a trouble condition present Refer to Displaying Trouble Conditions for instructions on how to display and correct trouble conditions If there was an Alarm If a one or more zones went into alarm while the system was armed a message similar to the one shown here will be displayed Use the and Keys to scroll through...

Page 8: ...etector is reset but goes into alarm again after the 90 second delay the fire alarm will sound again and the process described above will repeat A fire alarm will be transmitted to your monitoring station after 30 seconds if it is not silenced by pressing the Key Smoke detectors installed on your system may be reset after a false alarm using the 4 command To reset smoke detectors to normal first c...

Page 9: ...ccurs and your system is set for Engineer Reset you must call your alarm company to reset the system before it can be re armed In this instance the memory light will remain ON until reset by the installer Bypassing Zones A bypassed zone will not cause an alarm Zones may be bypassed to allow access to part of the protected area while other zones are armed For example bypassing the zone protecting y...

Page 10: ...he keypad The LCD600 Keypad will display messages when using the Bell Test command Refer to Page 22 for instructions on performing a Bell Test with the LCD600 Keypad Weekly Testing It is recommended that you test your system regularly NOTE Perform system tests in the off peak hours such as early morning or late evening 1 Call to inform your monitoring station that you are testing your system 2 Dis...

Page 11: ...d to allow someone to arm the system without that person having to be provided with an Access Code When 0 is entered the Exit Delay will begin and the user may leave the premises through the Entry Exit door At the end of the Exit Delay the Armed light will come ON and the system will be fully armed To turn the Quick Arm feature ON and OFF enter 6 Master Code 4 If Quick Arm is being turned ON the k...

Page 12: ...esent For Mains AC Failure the Trouble light will come ON as soon as the mains fails and will remain ON until power is restored LCD6OO 13 LCD6OO CHANGING SYSTEM FEATURES Changing Access Codes The PC2580 features 16 programmable Access Codes The first code is the Master Code and the remaining 15 codes are normal Access Codes Programming Access Codes Enter 5 Master Code the Program light will FLASH ...

Page 13: ...pproval of the apparatus if as a result it then ceases to comply with the standards against which approval was granted This apparatus has been approved for connection to the Public Switched Telephone Network PSTN including BT Kingston Upon Hull and Mercury This apparatus is not suitable for use as an extension to a payphone Only the network operator or a person authorised by the network operator i...

Reviews: