UL Listed Residential Installations

Residential Installations

• The entry delay must not exceed 45 seconds
• The exit delay must not exceed 60 seconds.
• The minimum bell cutoff time is 4 minutes.

Programming

The notes in the programming sections describing the system configurations
for UL Listed installations must be implemented.

Control of the Protected Premises

In order to have a UL Certificated system the protected area is to be under the
responsibility of one ownership and management (i.e. one business under one
name). This may be a group of buildings attached or unattached with different
addresses but under the responsibility of someone having mutual interest. The
person of mutual interest is not the alarm installing company.

Bell Location

The alarm sounding device (bell) must be located where it can be heard
by the person or persons responsible for maintaining the security system
during the daily arming cycle.

Protection of the Control Unit

The local control and the local power supply must be protected by one of
the following ways:
• The control unit and audible alarm device must be in a protected area

which is armed 24 hours a day.

• Each partition shall arm the area protecting the control unit and the

audible alarm device power supply. This may require duplicate
protection armed by each partition. Access to this protected area,
without causing an alarm, will require that all partitions be disarmed.

In all cases described above, the protected area for the control unit must
be programmed as not bypassable.

Casual Users

The installer should caution the user(s) to not give system information to
casual users (e.g. codes, bypass methods, etc. to baby-sitters or service
people). Only the One-Time Use codes should be given to casual users.

User Information

The installer should advise the users and note in the user instruction manual:
• Service organization name and telephone number
• The programmed exit time
• The programmed entry time

FCC Compliance Statement

CAUTION: Changes or modifications not expressly approved by Digital Security Controls
Ltd. could void your authority to use this equipment.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there
is no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:

• Re-orient the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the

receiver is connected.

• Consult the dealer or an experienced radio/television technician for help.

The user may find the following booklet prepared by the FCC useful: “How to Identify and
Resolve Radio/Television Interference Problems”. This booklet is available from the U.S.
Government Printing Office, Washington D.C. 20402, Stock # 004-000-00345-4

Important Information
This equipment complies with Part 68 of the FCC Rules. On the side of this equipment is a
label that contains, among other information, the FCC registration number of this equipment.
Notification to Telephone Company
Upon request, the customer shall notify the telephone company of the particular line to which
the connection will be made, and provide the FCC registration number and the ringer
equivalence of the protective circuit.
FCC Registration Number: F53CAN-73151-AL-E
Ringer Equivalence Number: 0.1B

USOC Jack: RJ-31X

Telephone Connection Requirements
Except for the telephone company provided ringers, all connections to the telephone network
shall be made through standard plugs and telephone company provided jacks, or equivalent,
in such a manner as to allow for easy, immediate disconnection of the terminal equipment.
Standard jacks shall be so arranged that, if the plug connected thereto is withdrawn, no

interference to the operation of the equipment at the customer’s premises which remains
connected to the telephone network shall occur by reason of such withdrawal.
Incidence of Harm
Should terminal equipment or protective circuitry cause harm to the telephone network, the
telephone company shall, where practicable, notify the customer that temporary disconnection
of service may be required; however, where prior notice is not practicable, the telephone
company may temporarily discontinue service if such action is deemed reasonable in the
circumstances. In the case of such temporary discontinuance, the telephone company shall
promptly notify the customer and will be given the opportunity to correct the situation.
Additional Telephone Company Information
The security control panel must be properly connected to the telephone line with a USOC
RJ-31X telephone jack.
The FCC prohibits customer-provided terminal equipment be connected to party lines or to
be used in conjunction with coin telephone service. Inter-connect rules may vary from state
to state.
Changes in Telephone Company Equipment of Facilities
The telephone company may make changes in its communications facilities, equipment,
operations or procedures, where such actions are reasonably required and proper in its
business. Should any such changes render the customer’s terminal equipment incompatible
with the telephone company facilities the customer shall be given adequate notice to the
effect modifications to maintain uninterrupted service.
Ringer Equivalence Number (REN)
The REN is useful to determine the quantity of devices that you may connect to your
telephone line and still have all of those devices ring when your telephone number is called.
In most, but not all areas, the sum of the RENs of all devices connected to one line should
not exceed five (5.0). To be certain of the number of devices that you may connect to your
line, you may want to contact your local telephone company.
Equipment Maintenance Facility
If you experience trouble with this telephone equipment, please contact the facility indicated
below for information on obtaining service or repairs. The telephone company may ask that
you disconnect this equipment from the network until the problem has been corrected or
until you are sure that the equipment is not malfunctioning.
Digital Security Controls Ltd., 160 Washburn Street, Lockport, NY 14094

Summary of Contents for PC155O

Page 1: ...G This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read Software Version 4 1 DLS 1 V6 5 and later ...

Page 2: ...ering 12 30 Reset to Factory Default 12 31 4th System Option Code 12 32 5th System Option Code 12 33 Answering Machine Double Call Timer 12 34 6th System Option Code 12 35 LINKS1000 Test Reporting Code 12 36 Keypad Lockout Control 13 90 Installer s Lockout Enable 13 91 Installer s Lockout Disable 13 Guidelines for Locating Smoke Detectors 13 For the Record 14 Programming Worksheets 15 PC1550 Contr...

Page 3: ...e printed circuit board the mounting hardware and the keypad from the cardboard retainer inside the cabinet Before attaching the cabinet to the wall press the four white nylon printed circuit board mounting studs into the cabinet from the back Once the cabinet is mounted to the wall pull all the cables into the cabinet and prepare them for connection Use a meter to test the wiring for opens shorts...

Page 4: ...current draw of 35 mA per keypad This represents the panel in the disarmed state with two zones open Fire Zone Wiring Any one of the 6 zones may be programmed as a Fire Loop See Programming Guide section 11 Z1 COM Z2 NC NO NC NC END OF LINE RESISTOR 1kΩ 0 5W END OF LINE RESISTOR 1kΩ 0 5W EOL RESISTOR LOOPS USING NO NC DEVICES EOL RESISTOR LOOPS USING NC DEVICES ONLY NOTE For UL installations zone ...

Page 5: ...n program the panel to prevent the user from being able to bypasscertainzones LightsforthesezoneswillnotcomeONinresponse to the bypass command See Zone Bypass Mask section 16 Trouble Conditions 2 The PC1550 continuously monitors a number of trouble conditions If one of these conditions occurs the keypad Trouble light will come ON and the buzzer will sound two short beeps every 10 seconds To silenc...

Page 6: ...ss code When the correct command is entered the keypad sounder and the PGM output will operate for 5 seconds be programmed with the downloading computer s telephone number the downloading access code and the panel identification code NOTE 4 command can be programmed to require an access code e g 4 access code in section 14 option 4 User Programming Commands 5 Pressing 5 allows the user to program ...

Page 7: ...memory which is accessible using the Installer s Programming code or via downloading If the Installer s code is forgotten the EEPROM may be reset to the factory default code See Section 30 Reset to Factory Default Programming With the panel in the disarmed mode enter 8 1500 The panel can only be programmed while it is in disarmed mode The default installer s code is 1500 it can be changed in secti...

Page 8: ...e second account code is always transmitted to the 2nd telephone number See 02 for programming instructions 05 to 10 Reporting Codes These sections are used to program the communicator reporting codes A reporting code is transmitted along with the account code with each transmission If the reporting codes are not programmed no transmission will be sent when an event takes place i e alarm restoral ...

Page 9: ...y for the report must be entered in section 19 NOTE For UL installations either AC failure or battery trouble reporting must be enabled 11 Zone Definitions As in the reporting codes sections once this section is entered 6 2 digit numbers are required Each 2 digit number entered defines how a zone will operate Zone Definitions Digit 1 The first digit determines whether the zone will cause a silent ...

Page 10: ...liary delay loop will not become active until both the auxiliary exit delay has expired and the loop is closed 8 Fire Loop Although a common fire signal is reported any one of the 6 zones may be programmed as a fire loop A fire loop is a supervised N O alarm initiating contacts end of line resistor circuit designed to accept latching 4 wire smoke detectors See the Control Panel Wiring Diagram On a...

Page 11: ...tion Variables Once this section is entered two 2 digit numbers are expected Do not press while entering data The first 2 digit number defines the number of attempts alarm and restoral pairs per zone that the communicator will make before it shuts down for that zone swinger shutdown The number of attempts is for the period as defined in the 1st System Option Code Section zone light 2 The number of...

Page 12: ...emove power from the devices connected The keypad buzzer will sound for the 5 second period 05 Courtesy Pulse This option provides an output which follows the entry and exit times It can be used to turn on a courtesy light near the exit door for the duration of the entry exit times 06 Keypad Buzzer Follow Mode The PGM output will go low as long as the keypad buzzer is ON for 24 Hour Buzzer Zone Do...

Page 13: ... to answer before the answering machine the answering machine will be unable to receive incoming calls 32 5th System Option Code Use the same method of programming as section 12 ZONE LIGHT 1 ON Loss of AC will not cause an AC trouble OFF Loss of AC will cause AC trouble 2 ON No bell during Auto Arm burst every 10 seconds is silenced OFF 1 burst of bell siren every 10 seconds during Auto Arm pre al...

Page 14: ... quantities of smoke precede detectable levels of heat in most cases For these reasons smoke detectors should be installed outside of each sleeping area and on each additional story of the dwelling The following information is for general guidance only The smoke detector manufacturer s literature should be consulted for detailed installation instructions On smooth ceilings detectors may be spaced ...

Page 15: ...__________________________________ ZONES Zone Type Protected Area 1 _____________________________ _________________________________________________________________________ 2 _____________________________ _________________________________________________________________________ 3 _____________________________ _________________________________________________________________________ 4 ______________...

Page 16: ... Zone 3 Restoral Zone 6 Restoral 07 Closing Arming Reporting Codes Partial Closing Reporting Code Page 9 Access Code 1 Access Code 4 Access Code 2 Access Code 5 Access Code 3 Access Code 6 Partial Closing Code 08 Opening Disarming Reporting Codes After Alarm Reporting Code Page 9 The after alarm code is sent on disarming if an alarm occured during the previous armed period Access Code 1 Access Cod...

Page 17: ...esistor loops ON Zone Light 6 Keypad P anic audible bell Keypad P anic silent bell 13 2nd System Option Code Page 11 Default Zone Light ON Zone Light OFF ON Zone Light 1 Call 1st phone only Backup to 2nd phone1 1 1 1 1 OFF Zone Light 2 Master Code not changeable Master Code changeable OFF Zone Light 3 Bell Squawk enabled2 2 2 2 2 Bell Squawk disabled OFF Zone Light 4 PC16 OUT enabled PC16 OUT disa...

Page 18: ...ON Zone Light 4 ON Zone Light 2 ON Zone Light 5 ON Zone Light 3 ON Zone Light 6 17 System Times Page 11 Default Default 0 3 0 Entry Delay seconds 0 3 0 AC fail transmission delay minutes 1 2 0 Exit Delay seconds 0 5 0 Slow loop response time x 10 ms 0 0 4 Bell Cut off minutes 0 3 0 Test transmission cycle or auto download cycle time days Valid entries are 001 to 255 Do not enter 000 Do not enter 0...

Page 19: ...seconds 7 08 Strobe Output latched alarm output 03 Utility Output Any Access Code 5 seconds 7 09 Failure to Communicate Output follows trouble 4 04 5 Second Reset Pulse 7 0A PGM ON during Entry Delay 05 Courtesy Pulse follows entry exit times 0B PGM ON during Exit Delay 06 Keypad Buzzer Follow Mode 0C LINKS1000 Interface 06 Buzzer follows the entry delay door chime auto arm alert period and 24 hou...

Page 20: ...lay normal ON Zone Light 6 Standard Fire Temporal Fire 33 Answering Machine Double Call Timer Page 14 Default 0 6 0 Valid entries are 001 to 249 34 6th System Option Code Page 14 Default Zone Light ON Zone Light OFF OFF Zone Light 1 Audible Exit Delay with Urgency Standard Exit Delay OFF Zone Light 2 Bell Squawk during Exit Delay No Bell Squawk during Exit Delay OFF Zone Light 3 Audible Exit Fault...

Page 21: ...g Diagram Incorrect connections may result in PTC failure or improper operation Inspect wiring and ensure connections are correct before applying power Do not route any wiring over circuit boards Maintain at least 1 25 4mm distance ...

Page 22: ...esolve Radio Television Interference Problems This booklet is available from the U S Government Printing Office Washington D C 20402 Stock 004 000 00345 4 Important Information This equipment complies with Part 68 of the FCC Rules On the side of this equipment is a labelthatcontains amongotherinformation theFCCregistrationnumberofthisequipment Notification to Telephone Company Uponrequest thecusto...

Page 23: ...reduce the effectiveness of these features It is important that a security system be reviewed periodically to ensure that its features remain effective and that it be updated or replaced if it is found that it does not provide the protection expected Access by Intruders Intruders may enter through an unprotected access point circumvent a sensing device evade detection by moving through an area of ...

Page 24: ... 2001 Digital Security Controls Ltd Toronto Canada www dsc com Printed in Canada 29003080 R003 1 800 387 3630 ...

Reviews: