18
PC1550 Version 4.1
[23] Communication Formats
Page 12
It is necessary to program the format for
both
numbers, even if the second telephone number is not used.
Default
Default
1
1st Telephone Number
1
2nd Telephone Number
Enter one HEX digit from [0] to [F] for each phone number from the following list:
[0]
SILENT KNIGHT / ADEMCO SLOW 10 BPS
(1400 Hz handshake)
3/1, 4/1 and 4/2 non-extended formats
[1]
SESCOA, FRANKLIN, DCI, VERTEX 20 BPS
(2300 Hz handshake)
3/1, 4/1 and 4/2 non-extended formats
[2]
SILENT KNIGHT FAST 20 BPS
(1400 Hz handshake)
3/1, 4/1 and 4/2 non extended formats
[3]
RADIONICS
(2300/1400 Hz handshake•)
3/1, 4/2 non extended formats
[4]
RADIONICS
(2300/1400 Hz handshake)
3/1, 4/2 non-extended with parity format
[5] -[7]
DO NOT USE
[8]
SILENT KNIGHT, ADEMCO SLOW 10 BPS
(1400 Hz handshake)
3/1 extended format
[9]
SESCOA, FRANKLIN, DCI, VERTEX 20 BPS
(2300 Hz handshake)
3/1 extended format
[A]
SILENT KNIGHT FAST 20 BPS
(1400 Hz handshake)
3/1 extended format
[B]
RADIONICS
(2300 / 1400 Hz handshake•) 3/1 extended format
[C]
RADIONICS
(2300 / 1400 Hz handshake•) 3/1 extended with parity format
[D]- [F]
DO NOT USE
• See Section [13] for Radionics handshake option.
[24] Programmable Output Options (PGM Terminal)
Page 13
Default
Enter 2 digits from “01” to “0C” only.
0 4
Programmable Output:
[01] Ground Start Pulse
[07] System Status (arm/disarm) Output
[02] Utility Output, No Access Code - 5 seconds [
✱
] [7]
[08] Strobe Output (latched alarm output)
[03] Utility Output, Any Access Code - 5 seconds [
✱
] [7]
[09] Failure to Communicate Output - follows trouble #4
[04] 5 Second Reset Pulse [
✱
] [7]
[0A] PGM ON during Entry Delay
[05] Courtesy Pulse (follows entry/exit times)
[0B] PGM ON during Exit Delay
[06] Keypad Buzzer Follow Mode•
[0C] LINKS1000 Interface
•
•
•
•
•
[06] Buzzer follows the entry delay, door chime, auto-arm alert period and 24 hour buzzer loop.
[25] Communicator Call Directions
Page 13
This section must be completely programmed. Do not press [#] to exit until all entries are completed.
Default
1
Zone Alarms and Restorals
[0] No transmissions for this group.
1
Access Code Openings and Closings
[1] Call 1st number and backup to 2nd number.•
1
Priority Alarms and Restorals
[2] Call 2nd phone number only.
1
Maintenance Alarms and Restorals
[3] Always call both phone numbers.
• Section [13] Light 1 “OFF” and 2nd phone number must be programmed.
[26] Downloading Telephone Number
Page 13
This telephone number is used by the panel to call the downloading computer either by the periodic download function or
through the use of the [
✱
] [4] command. Enter [0] for the digit ‘0’ in the phone number. Enter [
✱
4
✱
] (HEX D) for additional dial
tone detection between number digits, as in local PBX systems. Enter [#] to end the phone number entry.
[27] Downloading Access Code
Page 13
Default
1 5 1 5
This code allows the panel to confirm that a valid downloading computer is requesting access.
[28] Panel Identification Code
Page 13
Default
1 5 0 1
This code confirms the panel’s identity to the downloading computer.