2

Features

Keypad Programmable

The PC1550 is complete with a default program so that it is
operational with a minimum of programming. The control panel is
completely programmable from the keypad.

EEPROM Memory

The panel uses EEPROM memory which will retain all program
information even if AC and battery power are removed from the
panel. The EEPROM memory can be reprogrammed thousands of
times.

Static/Lightning Protection

The PC1550 has been carefully designed and tested to provide
reliable protection against static and lightning induced transients.
Our special “Zap-Trac” circuit board design catches high voltage
transients right at the wiring terminals, and transient protection
devices are placed in all critical areas to further reduce damaging
voltages.

Supervision

• Low or disconnected battery

• Loss of AC power

• Fuse open

• Loss of time on system clock

• Microprocessor “Watchdog” circuit

Operation

• Download / Upload capability

• Programmable auto downloading

• Swinger shutdown

• Transmission delay

• Six access codes

• “Master key” code

• All zones programmable as fire zones

• Programmable test transmission

• Zone bypass from the keypad

• Six zones

• Bell / Siren zone

• Programmable output

• Three dedicated keys (Fire/Auxiliary/Panic)

• Backlit, aesthetically pleasing keypad

Specifications

PC1550 Control Panel

• Six fully programmable zones

- EOL resistor supervised option
- all zones programmable as fire zones.
- maximum zone loop resistance: 100 ohms

• Bell / Siren outputs: 1 amp

- steady for burglary
- pulsed for fire

• Programmable output: 300 mA

9 programmable options

• Auxiliary power output: 475 mA

• PC1500RK keypad, 3 maximum

• Sealed Battery 12 V

DC

, 4 Ah minimum

• Transformer: 16 V

AC

, 40 VA

• Panel dimensions:

- 10" high x 8" wide x 3" deep (254 x 208 x 76 mm)
- Surface mount

• Panel colour: light beige

PC1500RK Keypad

• Three keypad activated zones:

Fire ,  Auxiliary, Panic

• Backlit keys

• 5 system lights:

Ready ,  Armed ,  Memory ,  Bypass ,  Trouble

• 6 zone lights

• Keypad dimensions:

- 4.5" H × 4.5" W × 0.93" D (114 × 114 × 23.6 mm)
- Surface mount

• Keypad colour: mist

Summary of Contents for PC1550

Page 1: ...9 04 2nd Account Code 9 05 to 10 Reporting Codes 9 05 Zone Alarm Reporting Codes 9 06 Zone Restoral Reporting Codes 9 07 Closing Arming Reporting Codes Partial Closing Reporting Code 9 08 Opening Disa...

Page 2: ...peration Download Upload capability Programmable auto downloading Swinger shutdown Transmission delay Six access codes Master key code All zones programmable as fire zones Programmable test transmissi...

Page 3: ...witched AC source and close to the telephone line connection Remove the printed circuit board the mounting hardware and the keypad from the cardboard retainer inside the cabinet Before attaching the c...

Page 4: ...fire generally rises to the ceiling spreads out across the ceiling surface and begins to bank down from the across the ceiling surface and begins to bank down from the across the ceiling surface and...

Page 5: ...before going to bed and is useful for users who have a keypad outside areas protected by the interior zones Arming Without Entry Delay To eliminate Entry Delay arm the system using 9 access code An ex...

Page 6: ...aster Code The installer may choose to not allow the user to program the Master Code section 13 option 2 The 6th code may be changed from a regular code into a One time Use code or Maid s Code section...

Page 7: ...ammable section 14 option 5 for feedback 3 beeps or silent no buzzer feedback If programmed for audible the buzzer will sound once the key input is accepted keep time When the panel is powered up the...

Page 8: ...mode For2 digitpairs bothdigitsmustbeprogrammed before pressing the key Only the data entered before pressing the key will be changed in the EEPROM Program Data Review Enter the section you wish to pr...

Page 9: ...2 digit code 31 TRANSMISSION SENT 1234 31 3 1 FORMAT Extended reporting requires 3 digit Account Code in section 02 or 04 i e Enter 1230 for code 123 Format Code 8 9 A B C depending on receiver type i...

Page 10: ...ny loop programmed for fire the Trouble light will come ON and the keypad sounder will beep every 10 seconds Thekeypadtroublebuzzerwillsoundandthe Trouble light will come ON regardless of whether the...

Page 11: ...r zone definitions 2 Exit delay time 001 to 255 seconds This value determines the standard Exit Delay time The factory default exit time is 120 seconds For zone definitions see Section 11 3 Bell cut o...

Page 12: ...the type of format which will be sent to each of the two telephone numbers programmed in section 01 and 03 For each telephone number enter one digit from the list below See the HEX data programming se...

Page 13: ...he Exit Delay This option may be used to provide lighting in the exit area or to activate a device when the Exit Delay begins 0C LINKS1000 Interface This option configures the system for use with the...

Page 14: ...Squawk during Entry Delay OFF No Bell Squawk during Entry Delay 6 ON F Key disabled OFF F Key enabled Factory default When Light 3 is ON Audible Exit Fault When the system is armed and a Standard Del...

Page 15: ...__________________________________ ZONES Zone Type Protected Area 1 _____________________________ __________________________________________________________________ 2 _____________________________ ___...

Page 16: ...Closing Arming Reporting Codes Partial Closing Reporting Code Page 9 Access Code 1 Access Code 4 Access Code 2 Access Code 5 Access Code 3 Access Code 6 Partial Closing Code 08 Opening Disarming Repo...

Page 17: ...sistor loops ON Zone Light 6 Keypad P anic audible bell Keypad P anic silent bell 13 2nd System Option Code Page 11 Default Zone Light ON Zone Light OFF ON Zone Light 1 Call 1st phone only Backup to 2...

Page 18: ...Light 6 17 System Times Page 11 Default Default 0 3 0 Entry Delay seconds 0 3 0 AC fail transmission delay minutes 1 2 0 Exit Delay seconds 0 5 0 Slow loop response time x 10 ms 0 0 4 Bell Cut off mi...

Page 19: ...econds 7 08 Strobe Output latched alarm output 03 Utility Output Any Access Code 5 seconds 7 09 Failure to Communicate Output follows trouble 4 04 5 Second Reset Pulse 7 0A PGM ON during Entry Delay 0...

Page 20: ...liary delay Auxiliary delay normal ON Zone Light 6 60 s bypass on power up Zones active on power up 33 Answering Machine Double Call Timer Page 14 Default 0 6 0 Valid entries are 001 to 249 34 6th Sys...

Page 21: ...ay consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all the devices does not exceed 100 The Load Number of this unit is 2 AVIS L tiquette de...

Page 22: ...ds of the Entry Delay to warn that the Entry Delay is about to expire Zone Light 5 Bell Squawk During Entry Delay The bell siren will squawk during the Entry Delay If Zone Light 4 is on the bell siren...

Page 23: ......

Page 24: ...l communications peut demander l utilisateur de d brancher un appareil la suite de r parations ou de modifications effectu es par l utilisateur ou cause de mauvais fonctionnement Pour sa propre protec...

Reviews: