17
PC1550 Version 4.0
[11]
Zone Definitions
Page 10
NOTE:
When defining zones, assign delay zones first to zones 1,2,3..., then assign the other zone types to the remaining
zones in any order desired.
Default
0 0
Zone 1
0 1
Zone 2
0 1
Zone 3
0 2
Zone 4
0 2
Zone 5
0 8
Zone 6
First Digit
Second Digit
0 = Slow, Audible
0 = Standard Delay
1 = Slow, Silent
1 = Instant
2 = Fast, Audible
2 = Interior
3 = Fast, Silent
3 = Interior, Home-Away
4 = 24 Hour Bell
5 = 24 Hour Bell/Buzzer
6 = 24 Hour Buzzer
7 = Aux. Delay (Uses Auxiliary
Entry/Exit Times)
8 = Fire•
•
•
•
•
• Any
one
zone may be set as a FIRE zone.
[12]
1st System Option Code
Page 11
Default
Zone Light ON
Zone Light OFF
OFF
Zone Light 1
Communicator disabled
Communicator enabled
OFF
Zone Light 2
TX limit to 24 hour period
TX limit to armed period
ON
Zone Light 3
Alarm display while armed
No alarm display while armed
ON
Zone Light 4
DTMF dialling
Pulse dialling
OFF
Zone Light 5
N.C. loops (except fire)
EOL resistor loops
ON
Zone Light 6
Keypad [P]anic audible (bell)
Keypad [P]anic silent (bell)
[13]
2nd System Option Code
Page 11
Default
Zone Light ON
Zone Light OFF
ON
Zone Light 1
Call 1st phone only
Backup to 2nd phone
1
1
1
1
1
OFF
Zone Light 2
Master Code not changeable
Master Code changeable
OFF
Zone Light 3
Bell Squawk enabled
2
2
2
2
2
Bell Squawk disabled
OFF
Zone Light 4
PC16 OUT enabled
PC16 OUT disabled
OFF
Zone Light 5
6th code is maid’s code
6th code normal
OFF
Zone Light 6
1400 Hz Radionics
2300 Hz Radionics
1
1
1
1
1
Do not program “OFF” unless 2nd phone number is programmed.
2
2
2
2
2
With Bell Squawk enabled, the bell/siren will sound one short burst on arming and two short bursts on disarming.
[14]
3rd System Option Code
Page 11
Default
Zone Light ON
Zone Light OFF
OFF
Zone Light 1
User code required for bypass
Code not required
OFF
Zone Light 2
[
*
] [4] Enabled
[
*
] [4] Disabled
OFF
Zone Light 3
Periodic downloading
Periodic test transmit
OFF
Zone Light 4
[
*
] [4] access code required
[
*
] [4] no code required
ON
Zone Light 5
[P]anic audible (buzzer)
[P]anic silent (buzzer)
OFF
Zone Light 6
Partial closing identified
Not identified
Summary of Contents for PC1550