14
Troubleshooting
S E C T I O N 7
1. When I enter [0013] RF4164-433 options, the keypad gives me a
long beep.
You cannot enter ESNs unless the RF4164-433 wireless receiver is enrolled. See section
2 for instructions on enrolling the RF4164-433 module.
2. I have entered the ESN for the device but when I violate the
device, the zone does not show open on the keypad.
Check the following:
•
Check that you are looking at a keypad on the same partition as the device you are testing
•
Check that the ESN has been entered correctly
•
Check that the zone is assigned to one or more partitions
3. When I try a module placement test I get no result or “Bad” results.
Check the following (see sections 4.1 and 4.2 for more information on testing devices):
•
Verify that you are testing the correct zone
•
Verify that the correct ESN was entered when the device was enrolled
•
Verify that the device is in range of the RF4164-433 receiver. Try testing the
device in the same room as the receiver
•
Confirm that the RF4164-433 receiver is properly connected to the Combus (see
section 2 for RF4164-433 receiver setup and wiring instructions)
•
Check that you are testing the zone correctly (see sections 4.1 and 4.2 for testing
instructions)
•
Check that the batteries are working and installed correctly
•
Look for large metal objects that may be preventing the signal from reaching
the RF4164-433 receiver
The device must be located where consistent “Good” or “Fair” results are obtained. If
several devices show “Bad” results, or if panic pendants and wireless keys operate
inconsistently, move the receiver. See section 2.3 for tips on choosing a mounting location
for the RF4164-433 receiver.
4. The LED on the motion detector does not turn on when I walk in
front of the unit.
The LED is for walk test purposes only. See your WLS904(L)-433
Instruction Sheet for wa
k test instructions.
firealarmresources.com