172
1)
When the IP camera is offline, connect PC and NVR with the RS-232 cable.
2)
Open the Super Terminal, use the ping command and keep sending large data packages to the
connected IP camera, and check if there exists packet loss.
Simultaneously press
Ctrl
and
C
to exit the ping command.
Example:
Input
ping 172.6.22.131 –l 1472 –f.
4.
Verify the switch is not flow control.
Check the brand, model of the switch connecting IP camera and NVR, and contact with the manufacturer
of the switch to check if it has the function of flow control. If so, please turn it down.
5.
Check if the fault is solved by the step 1 to step 4.
If it is solved, finish the process.
If not, please contact the engineer from our company to do the further process.
No monitor connected with the NVR locally and when you manage the IP camera to connect with the
device by web browser remotely, of which the status displays as Connected. And then you connect the
device with the monitor via VGA or HDMI
TM
interface and reboot the device, there is black screen with
the mouse cursor.
Connect the NVR with the monitor before startup via VGA or HDMI
TM
interface, and manage the IP
camera to connect with the device locally or remotely, the status of IP camera displays as Connect.
Possible Reasons:
After connecting the IP camera to the NVR, the image is output via the main spot interface by default.
Steps:
1.
Enable the output channel.
2.
Select “Menu > Configuration > Live View > View”, and select video output interface in the drop-down
list and configure the window you want to view.
The view settings can only be configured by the local operation of NVR.
Different camera orders and window-division modes can be set for different output interfaces
separately, and digits like “D1”and “D2” stands for the channel number, and “X” means the selected
window has no image output.
3.
Check if the fault is solved by the above steps.
If it is solved, finish the process.
If not, please contact the engineer from our company to do the further process.
Live view stuck when video output locally.
Possible Reasons:
a)
Poor network between NVR and IP camera, and there exists packet loss during the transmission.
b)
The frame rate has not reached the real-time frame rate.
Steps:
1.
Verify the network between NVR and IP camera is connected.
1)
When image is stuck, connect the RS-232 ports on PC and the rear panel of NVR with the RS-232
cable.
2)
Open the Super Terminal, and execute the command of “
ping
192.168.0.0
–l 1472 –f
”
(the IP address
may change according to the real condition), and check if there exists packet loss.
Summary of Contents for DSC-N114
Page 1: ...DSC N114_Network_Video_Recorder User Manual 8200 1116 06...
Page 2: ...1...
Page 8: ...7 Troubleshooting 170 List of Compatible IP Cameras 176...
Page 9: ...8 Chapter 1 Introduction...
Page 17: ...16 Chapter 2 Getting Started...
Page 22: ...21 Figure 2 9 Record Settings 12 Click OK to complete the startup Setup Wizard...
Page 34: ...33 Chapter 4 PTZ Controls...
Page 42: ...41 Chapter 5 Recording Settings...
Page 49: ...48 Figure 5 10 Copy Schedule to Other Channels...
Page 79: ...78 Chapter 7 Backup...
Page 94: ...93 Chapter 8 Alarm Settings...
Page 111: ...110 Chapter 9 Network Settings...
Page 128: ...127 Chapter 10 HDD Management...
Page 138: ...137...
Page 142: ...141 Chapter 11 Camera Settings...
Page 145: ...144 Figure 11 3 Set Privacy Mask Area 6 Click the Apply button to save the settings...
Page 147: ...146 Chapter 12 NVR Management and Maintenance...
Page 159: ...158 Chapter 13 Others...
Page 169: ...168 Chapter 14 Appendix...