171
If not, please contact the engineer from our company to do the further process.
The status of the added IP camera displays as “Disconnected” when it is connected through Private
Protocol. Select “Menu>Camera>Camera>IP Camera” to get the camera status.
Possible Reasons
a)
Network failure, and the NVR and IP camera lost connections.
b)
The configured parameters are incorrect when adding the IP camera.
c)
Insufficient bandwidth.
Steps
1.
Verify the network is connected.
1)
Connect the NVR and PC with the RS-232 cable.
2)
Open the Super Terminal software, and execute the ping command. Input “ping IP” (e.g. ping
172.6.22.131).
Simultaneously press
Ctrl
and
C
to exit the ping command.
If there exists return information and the time value is little, the network is normal.
2.
Verify the configuration parameters are correct.
1)
Select “Menu>Camera>Camera>IP Camera”.
2)
Verify the following parameters are the same with those of the connected IP devices, including IP
address, protocol, management port, user name and password.
3.
Verify the whether the bandwidth is enough.
1)
Select “Menu >Maintenance > Net Detect > Network Stat.”.
2)
Check the usage of the access bandwidth, and see if the total bandwidth has reached its limit.
4.
Check if the fault is solved by the step 1 to step 3.
If it is solved, finish the process.
If not, please contact the engineer from our company to do the further process.
The IP camera frequently goes online and offline and the status of it displays as “Disconnected”.
Possible Reasons
a)
The IP camera and the NVR versions are not compatible.
b)
Unstable power supply of IP camera.
c)
Unstable network between IP camera and NVR.
d)
Limited flow by the switch connected with IP camera and NVR.
Steps
1.
Verify the IP camera and the NVR versions are compatible.
1)
Enter the IP camera Management interface “Menu > Camera > Camera>IP Camera”, and view the
firmware version of connected IP camera.
2)
Enter the System Info interface “Menu>Maintenance>System Info>Device Info”, and view the
firmware version of NVR.
2.
Verify power supply of IP camera is stable.
1)
Verify the power indicator is normal.
2)
When the IP camera is offline, please try the ping command on PC to check if the PC connects with
the IP camera.
3.
Verify the network between IP camera and NVR is stable.
Summary of Contents for DSC-N114
Page 1: ...DSC N114_Network_Video_Recorder User Manual 8200 1116 06...
Page 2: ...1...
Page 8: ...7 Troubleshooting 170 List of Compatible IP Cameras 176...
Page 9: ...8 Chapter 1 Introduction...
Page 17: ...16 Chapter 2 Getting Started...
Page 22: ...21 Figure 2 9 Record Settings 12 Click OK to complete the startup Setup Wizard...
Page 34: ...33 Chapter 4 PTZ Controls...
Page 42: ...41 Chapter 5 Recording Settings...
Page 49: ...48 Figure 5 10 Copy Schedule to Other Channels...
Page 79: ...78 Chapter 7 Backup...
Page 94: ...93 Chapter 8 Alarm Settings...
Page 111: ...110 Chapter 9 Network Settings...
Page 128: ...127 Chapter 10 HDD Management...
Page 138: ...137...
Page 142: ...141 Chapter 11 Camera Settings...
Page 145: ...144 Figure 11 3 Set Privacy Mask Area 6 Click the Apply button to save the settings...
Page 147: ...146 Chapter 12 NVR Management and Maintenance...
Page 159: ...158 Chapter 13 Others...
Page 169: ...168 Chapter 14 Appendix...