![DryGair DG-X Installation, Operation And Maintenance Manual Download Page 45](http://html.mh-extra.com/html/drygair/dg-x/dg-x_installation-operation-and-maintenance-manual_2533277045.webp)
DryGair Dehumidification Unit Model DG-X
Maintaining the Unit
Ver. 12/2020
39
3.
Prepare cleaning substances as detailed in the instructions of the
cleaning substance manufacturer.
4.
Apply or spray the material along the drainage pan, at a slow flow.
5.
Reconnect the drainage pan and the drainage tube in reverse order to the
disassembly.
6.
After completing the pan cleaning, leave the unit doors and covers open to
ensure all internal parts are dry.
7.
Check the electrical compartment to ensure nothing got wet and that
there is no moisture.
7.5.5
Antibacterial and Antifungal Treatment
It is possible to apply antibacterial and antifungal materials approved for air
conditioning systems to disinfect the coils and drainage pan. For Example,
ACE® Evap-Guard or ACE® Evap-Gard Plus. Make sure to follow the
manufacturer's instructions to guarantee the integrity of the unit.
Caution
Growers using sulfur or other chemicals should request units that are
treated for chemical resistance.