Page 5
For technical questions, please call 1-888-866-5797.
Item 56599
Specifications
Horse Power
1/4 HP
Electrical Rating
120VAC / 60Hz / 2.0A
Power Cord Length
25’
Maximum Flow @ 0’
1750 GPH
Maximum Head lift @ 0’ Flow
26′
Discharge Port
1″ NPT
Check Value Output Port
3/4″ Female NPT
Operating Water Depth
Minimum 2″
Installation
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION:
Unplug the Pump from its electrical outlet before setup or installation.
The utility pump must be installed upright and in a stationary position with a flexible hose.
Please note!
1. Do not install the pump by suspending it
unsupported from its discharge hose or power cord.
The pump must be placed level at the bottom of a
surface. To ensure that the pump works properly,
keep the bottom free from sludge and dirt of all kinds.
2. If the water level sinks too low, any sludge on the
surface will dry out and stop the pump from starting.
To help ensure the pump will start as required,
check the pump regularly with start-up tests.
Power Supply
1. The pump is equipped with a shock-
proof plug according to regulations The
pump is designed to be connected to a
120 VAC, 60Hz GFCI protected circuit.
2. Make sure that the plug and socket are
sufficiently secured and in excellent condition.
3.
WARNING: To prevent death from electric
shock, pump must be connected only to
a GFCI protected outlet.
WARNING!
If the power cord or plug is damaged,
do not use the pump. The power cord or plug
may only be repaired by a certified electrician.
Areas of use
1. This pump is designed for water removal only:
Removing water from crawl spaces, window
wells, flat roofs, and flooded yards.
2. This pump should NOT be used for water transfer or:
Continuous run, fountain/pond water features.
Permanent basement sump systems.
Septic or sewage systems.