background image

Page 4

For technical questions, please call 1-888-866-5797.

Item 56599 

        

Grounding

TO PREVENT ELECTRIC SHOCK AND DEATH FROM 
INCORRECT GROUNDING WIRE CONNECTION: 
Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded.  
Do not modify the power cord plug provided with the tool.  Never remove the grounding prong from 

the plug.  Do not use the tool if the power cord or plug is damaged.  If damaged, have it repaired by a service 
facility before use.  If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician.

Grounded Tools: Tools with Three Prong Plugs

 

3-Prong Plug and Outlet

1.  Tools marked with “Grounding Required” have a three 

wire cord and three prong grounding plug.  The plug 
must be connected to a properly grounded outlet.  If 
the tool should electrically malfunction or break down, 
grounding provides a low resistance path to carry 
electricity away from the user, reducing the risk of 
electric shock.  

(See “3-Prong Plug and Outlet”.)

2.  The grounding prong in the plug is connected through 

the green wire inside the cord to the grounding 
system in the tool.  The green wire in the cord must 
be the only wire connected to the tool’s grounding 
system and must never be attached to an electrically 
“live” terminal.  

(See “3-Prong Plug and Outlet”.)

3.  The tool must be plugged into an appropriate outlet, 

properly installed and grounded in accordance with 
all codes and ordinances.  The plug and outlet should 
look like those in the preceding illustration.   

(See “3-Prong Plug and Outlet”.)

Extension Cords

Extension cords must not be used with this pump.

Symbology

V

Volts

~

Alternating Current

A

Amperes

WARNING marking concerning Risk 
of Eye Injury.  Wear ANSI-approved 
safety goggles with side shields.

Read the manual before 
set-up and/or use.

WARNING marking concerning 
Risk of Electric Shock.  
Properly connect power cord 
to appropriate outlet.

Summary of Contents for 56599

Page 1: ...s manual and the receipt in a safe and dry place for future reference 19i When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2019 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express wr...

Page 2: ...cations This unit is NOT designed for use in septic tanks or underground vaults to pump raw sewage or effluents NEVER use in hazardous or explosive locations 14 Do not pump flammable or explosive liquids such as oil gasoline kerosene ethanol etc Do not use in the presence of flammable or explosive vapors Using this pump with or near flammable liquids can cause an explosion or fire resulting in pro...

Page 3: ...llow the instructions regarding common pump problems and remedies 31 This pump is fully automatic in operation If the water level is over 2 in the water detector senses water Then the control system built in the pump automatically starts the pump and the pump continues to run until water is pumped down to 3 4 in deep and then it stops If the water level is not over 2 in the pump will not start 32 ...

Page 4: ... break down grounding provides a low resistance path to carry electricity away from the user reducing the risk of electric shock See 3 Prong Plug and Outlet 2 The grounding prong in the plug is connected through the green wire inside the cord to the grounding system in the tool The green wire in the cord must be the only wire connected to the tool s grounding system and must never be attached to a...

Page 5: ... kinds 2 If the water level sinks too low any sludge on the surface will dry out and stop the pump from starting To help ensure the pump will start as required check the pump regularly with start up tests Power Supply 1 The pump is equipped with a shock proof plug according to regulations The pump is designed to be connected to a 120 VAC 60Hz GFCI protected circuit 2 Make sure that the plug and so...

Page 6: ...Strainer attached to filter out debris and stabilize the pump Discharge Debris Strainer Switch Housing Base and Inlet Screen Latches Connecting Discharge Hose sold separately 1 If using a 3 4 hose screw one end of the hose to the Check Valve until tight To minimize leaks use a hose that has a 3 4 threaded connector and rubber gasket 2 If using a 1 1 4 discharge hose connect a 3 4 adapter sold sepa...

Page 7: ...one end of the included 25 rope to the pump handle Secure with a knot 3 Lower pump with Debris Strainer attached in a low area where water accumulates Do not drop the pump into a depth of more than 13 or the automatic switch may not function properly Be sure pump sits fully upright 4 Secure the rope outside the water for easy access a Be careful not to pinch or damage the rope cord or hose b Place...

Page 8: ...aches outlet without any strain to cord 5 Secure the end of the rope outside the water collection area for easy access 6 Place pump in the lowest spot on surface where water accumulates Be sure pump sits fully upright 7 To position pump on a surface you cannot walk on hold rope walk around parameter and gently pull pump with rope Be careful to guide hose and power cord as you position the pump 8 O...

Page 9: ...st have contact with water to automatically start the pump 4 The pump will not run dry Once the pump detects that water is no longer being removed it will shut down automatically Note The pump must remain upright and level at all times for water detection to function properly Do not allow the pump to operate on its side or inverted The shaft seal depends on water for lubrication Allowing the pump ...

Page 10: ...he motor from a locked impeller which can be caused by debris build up or a frozen impeller When the pump is activated and the impeller is detected to be locked the unit will automatically shut down to protect the motor from overheating Once the pump is able to operate correctly the pump will resume normal operation Troubleshooting Problem Possible Causes Possible Solutions Pump runs but delivers ...

Page 11: ...EMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Part Description Qty 1 Shaft 1 2 Impeller 1 3 Diffuser 1 4 Screw 4 5 Base and Inlet Screen 1 6 Screw 3 7 Debris St...

Page 12: ...damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchand...