remove the flue exhaust ring from the top plate by loosening
the 2 nuts;
●
mount the flue exhaust ring to the rear wall using 2 nuts;
●
fix the convection plate again, using the allen screws;
●
mount the flue exhaust cover plate in the opening in the top
plate, using the 2 nuts.
5.4 INSTALLING
THE
FIRE
Install the fire as follows:
-
Do not make any changes to the fire;
-
mount the fire on a floor of sufficient load-bearing
strength;
-
place the fire and/or the flue pipes against a
wall made of non-combustible material;
-
place the fire and/or the flue pipes at least 50
mm away from the wall;
-
always place the fire and/or the flue pipes
at a minimum distance of 800 mm from
combustible objects and/or materials;
-
place the fire on a fire-resistant floor plate
extending 300 mm in front of the fire, if it
is placed on a floor made of combustible
material;
-
do not cover the fire and/or do not wrap it in
an insulation blanket or any other material;
-
observe the requirements for the flue duct, as
stated in paragraph 5.2.
●
Determine the location of the fire; the dimensions can be
found in appendix 2.
●
If necessary, install a floor plate.
●
Place the fire in its intended location.
●
Check if the vermiculite plates and the baffle plates are
placed correctly in the fire (see user manual).
●
If necessary, correct the position of the plates.
●
Connect the fire to the flue duct.
5.5
INSTRUCTIONS FOR EACH FIRE TYPE
●
Babe
-
If the exhaust is moved, the top plate concerned will have to
be ordered. For this, contact your supplier.
●
Babe Swing
-
Level the fire, using the adjustable feet;
-
on top of the fire you will see a rotating ring into which the
flue pipe will turn;
-
If necessary, the resistance of the rotation system can
be adjusted. The resistance of the rotation system can
be adjusted using an adjusting nut at the bottom, in
the middle of the foot. For this purpose, the fire can be
tilted backwards. By tightening the nut, the resistance is
increased.
●
Kalle
-
If the exhaust is moved, the top plate concerned will have to
be ordered. For this, contact your supplier;
-
in order to replace the side glass panes, you must remove
the side panels;
-
lift the top plate;
-
loosen the fastening bolts of the side plates;
-
lift the side plates from the brackets;
-
the glass pane clips can now be removed
●
Tor
-
The Tor is provided with a non-lockable outside air
connection of 100 mm. Depending on regulations, it can be
connected to a lockable grate.
●
Vidar Small /Medium / Large
-
The Vidar series is provided with a lockable outside air
connection of 80 mm. Both at the bottom and at the rear, it
can be connected with a flexible aluminium pipe of 80 mm
diameter. For this, remove the cover plate.
English
Dik Geurts
17
!
Caution
Summary of Contents for Babe
Page 2: ...Typeplaatje Data plate La plaque signal tique...
Page 63: ...Dik Geurts 61 Babe Babe Swing Kalle Tor Lars 800 Lars 900...
Page 64: ...62 Lars 1100 Lars 1300 Vidar Small Vidar Medium...
Page 65: ...Dik Geurts 63 Vidar Large Pelle Mats Jannik...
Page 66: ...64 Jens L H Vidar Triple Vidar Wall...
Page 67: ...Dik Geurts 65 Afb 4 Vidar Wall Vidar Triple Afb 1 Afb 2 Afb 3...
Page 68: ......