6.2 ACTIVATING THE BATTERY FOR REAL TIME CLOCK FUNCTIONS
By inserting the Jumper into the bridging pins, the battery function is activated and this allows the
VIP5 Pro controller
to operate with the Date/time and status save function when the power is removed.
6.3 PRECAUTIONS TO BE USED WHEN CARRING OUT WIRING
There is no specific safety risks associated with this device. Use general precautions that you would use when
operating an electrical device. All wiring should be carried out by a qualified electrician.
•
Before wiring the panel ensure correct voltage as indicated on the product label.
•
Only perform wiring operations once you are sure power is off and cannot be accidentally switched on.
•
A circuit breaker that is easy accessible must be used in the wiring of the pump. Ensure the break contact has a
contact distance of at least 3 mm
•
The power connections and pump must have armoured insulation until entrance into the terminals. The cable must be
positioned to have no damage to the insulation sleeve.
•
Up to the terminal connections. The cable must be routed to avoid damage to the outer isolation sheaf.
•
It is advisable to use a fuse or a differential isolation to protect the device. The device should have a recommended
value of 0,03 Ampere with 1 milllisecond maximum activation time. Isolation capability ≥ 10kV and nominal ln=6A.
Note: Every time the battery jumper is removed and reinserted causes the DATE/TIME function to be
set to zero. Therefore it is recommended that after inserting the battery jumper, the date and time is
set.
Set the JUMPER (as
shown) to ability the
battery
BATTERY