DROPSA VIP4ToolsPro User And Maintenance Manual Download Page 4

 

6. INSTALLATION

 

 

6.1 UNPACKING 

Once  a  suitable  location  has  been  identified  for  the  installation,  open  the  package  and  remove  the 
equipment. Check that the VIP4Tools

Pro

 has not sustained damage during transport and storage. 

The  packaging  material  does  not  require  any  special  disposal  precautions,  not  being  in  any  way 
dangerous or polluting. 
 

6.2 MOUNTING THE VIP4Tools PANEL 

Provide adequate space for the installation, leaving a minimum room of 100 mm around the panel. Mount 
the  VIP4Tools

Pro

  panel  at  shoulder  height  to  avoid  unnatural  posture  or  the  possibility  of  sustaining 

impacts. Do not install the  VIP4Tools

Pro

 in particularly aggressive or explosive/flammable environments 

or on components subject to vibration. 
Only use the supplied mounting bracket with N° 2 holes for Ø 6 mm (0.23 in.) bolts. 
 

6.3 MOUNTING THE MINI-PUMPS ON THE MIXER BASES

 (for replacement or augmenting) 

The mini-pumps are mounted on the mixer bases utilizing two securing screws. 
Particular attention should be paid to the correct positioning of the o-rings between the mini-pump and the 
mixer base (see diagram below). 

 
 
 
 
 
 

 
 
 
 
 
 
 
 

 
 
 
 

 

 

 
 
 
 
 
 
 
 
 
 

6.4 HYDRAULIC CONNECTIONS 

The only connection to be undertaken is that of the individual pumps, provided with push-in connections, 
to the lubrication point. The piping can be either  co-axial with 6mm external and 3mm internal tubing, or 
straight 4mm tube. (obtainable from Dropsa).

 

 

6.5 PNEUMATIC CONNECTIONS 

Connect the air input to the push-in connector utilizing Ø 8mm  nylon tubing both for the pump and the 
mixer, and provide a stop valve to permit shutting off the supply.

 

.

 

 

o’rings 

Summary of Contents for VIP4ToolsPro

Page 1: ...STRUCTIONS FOR USE 8 MAINTENANCE 9 DISPOSAL 10 ORDERING INFORMATION 11 DIMENSIONS 12 HANDLING AND TRANSPORTATION 13 PRECAUTION IN USE 14 CONTRAINDICATIONS http www dropsa com Via Benedetto Croce 1 Vim...

Page 2: ...mmediately replaced After long periods of inactivity check air tightness of all parts subjected to pressure Personnel must use personal protection equipment clothing and tools adequate for the locatio...

Page 3: ...re 10 C 80 C 14 F 176 F Maximum switching power 50 W 5 V Maximum current 1 A Maximum voltage 220 V AC 5 DESCRIPTION OF COMPONENTS Central VIP4ToolsPro Unit The central unit of the lubrication system i...

Page 4: ...r on components subject to vibration Only use the supplied mounting bracket with N 2 holes for 6 mm 0 23 in bolts 6 3 MOUNTING THE MINI PUMPS ON THE MIXER BASES for replacement or augmenting The mini...

Page 5: ...ecifications 6 6 1 Schematic electrical connection Samba Level NC electric level in the absence of lubricant 6 6 2 Schematic electrical solenoid connection Connector 39979 EV 24 V DC non polarized N B...

Page 6: ...6 EXAMPLE OF TUBING AND NOZZLE CONNECTION STRAIGHT TUBING CO AXIAL TUBING CONNECTION...

Page 7: ...s to an increase in flow of 5 mm until reaching 30 mm at the 7th turn see table FLOW mm stroke TURNS 30 6 5 25 5 5 20 4 5 15 3 5 10 2 5 5 1 5 0 no pump delivery Completely unscrewed 7 4 OUTLET AIR FLO...

Page 8: ...rder that any leaks will be immediately evident When necessary replace the oil filling filter P N 3130139 Periodically empty the pressure regulator condensate trap by rotating the small red valve loca...

Page 9: ...rication Points with pneumatic timer 3 Liters 24V AC 50 60Hz 3704320 2 Lubrication Points with pneumatic timer 3 Liters 24V AC 50 60Hz 3704330 3 Lubrication Points with pneumatic timer 3 Liters 24V AC...

Page 10: ...IR FLOW REGULATOR SOLENOID VALVE 24 V DC AIR SUPPLY Push in 8 tubing LUBRICANT EXIT 6 3 co axial 4 Mono tubing PUMP STROKE ADJUSTMENT AIR FLOW REGULATIOR ELECTRIC LEVEL FILLER PLUG SOLENOID CABLE GLAN...

Page 11: ...electronic tank and base structure must be connected to the ground line see paragraph 6 7 Flammability The oil employed in the lubrication circuit is not normally flammable It is nonetheless indispen...

Page 12: ...The operator coming into contact with fluid due to breakage opening of supply tubing The operator must be furnished with suitable personal protection clothing equipment according to current regulation...