12. HANDLING AND TRANSPORTATION

 

 

Prior  to  dispatch  VIP4Tools

Pro

  lubrication  panels  are  carefully  packed  in  a  cardboard  carton.  During 

transportation and storage maintain the equipment the right way up as indicated on the carton.  

On receipt, check that the packaging is not damaged and store the equipment in a dry place. 

 

 
13. PRECAUTIONS IN USE 

 

It  is  necessary  to  carefully  read  the  warnings  and  the  risks  involved  in  using  the  lubrication  panel.  The 
operator must understand the functioning of the unit by studying  the user’s manual. 

 

Electric currents 

No intervention must be attempted on the equipment without first having disconnected the electrical power 
supply (electric level) and ensuring that it cannot be reconnected during the intervention. 
All  installed  equipment,  electrical,  electronic,  tank  and  base  structure,  must be  connected  to  the  ground 
line. 

(see paragraph 6.7).

 

Flammability 
The  oil  employed  in  the  lubrication  circuit  is  not  normally  flammable.  It  is  nonetheless  indispensable  to 
take every precaution against the oil coming into contact with very hot parts or open flames.  
Pressure 
Prior  to  any  intervention  on  the  equipment  ensure  that  pressure  is  released  from  all  branches  of  the 
lubrication circuit. Failure to do this could result in oil being discharged under pressure where connections 
or components are disassembled 

(see paragraph 6.6). 

Noise 
The VIP4Tools

Pro

 lubrication panel does not emit excessive noise, remaining below 70 dB(A). 

 
 

 

AIR CHARACTERISTICS 

 

            

Before carrying out the replacement of the mini-pumps, empty the tank of lubricant. 

 

AIR OUTLET FOR LIMIT 
PNEUMATIC SWITCH 
(push in tube Ø8) 

ELECTRIC LEVEL 

FILLER 

PLUG 

INTAKE AIR 

Push-in  Ø8 tubing 

AIR/OIL OUTLET 

Ø6/3 (coaxial) – Ø4 (straight) 

AIR FLOW 
REGULATOR 

 PUMP STROKE 
ADJUSTMENT  

SOLENOID VALVE 

24 V DC 

SOLENOID 

CABLE GLAND  

PER EV 

AIR INLET FROM PNEUMATIC 
SWITCH 
(push in tube Ø8) 

Summary of Contents for VIP4ToolsPro

Page 1: ...STRUCTIONS FOR USE 8 MAINTENANCE 9 DISPOSAL 10 ORDERING INFORMATION 11 DIMENSIONS 12 HANDLING AND TRANSPORTATION 13 PRECAUTION IN USE 14 CONTRAINDICATIONS http www dropsa com Via Benedetto Croce 1 Vim...

Page 2: ...mmediately replaced After long periods of inactivity check air tightness of all parts subjected to pressure Personnel must use personal protection equipment clothing and tools adequate for the locatio...

Page 3: ...re 10 C 80 C 14 F 176 F Maximum switching power 50 W 5 V Maximum current 1 A Maximum voltage 220 V AC 5 DESCRIPTION OF COMPONENTS Central VIP4ToolsPro Unit The central unit of the lubrication system i...

Page 4: ...r on components subject to vibration Only use the supplied mounting bracket with N 2 holes for 6 mm 0 23 in bolts 6 3 MOUNTING THE MINI PUMPS ON THE MIXER BASES for replacement or augmenting The mini...

Page 5: ...ecifications 6 6 1 Schematic electrical connection Samba Level NC electric level in the absence of lubricant 6 6 2 Schematic electrical solenoid connection Connector 39979 EV 24 V DC non polarized N B...

Page 6: ...6 EXAMPLE OF TUBING AND NOZZLE CONNECTION STRAIGHT TUBING CO AXIAL TUBING CONNECTION...

Page 7: ...s to an increase in flow of 5 mm until reaching 30 mm at the 7th turn see table FLOW mm stroke TURNS 30 6 5 25 5 5 20 4 5 15 3 5 10 2 5 5 1 5 0 no pump delivery Completely unscrewed 7 4 OUTLET AIR FLO...

Page 8: ...rder that any leaks will be immediately evident When necessary replace the oil filling filter P N 3130139 Periodically empty the pressure regulator condensate trap by rotating the small red valve loca...

Page 9: ...rication Points with pneumatic timer 3 Liters 24V AC 50 60Hz 3704320 2 Lubrication Points with pneumatic timer 3 Liters 24V AC 50 60Hz 3704330 3 Lubrication Points with pneumatic timer 3 Liters 24V AC...

Page 10: ...IR FLOW REGULATOR SOLENOID VALVE 24 V DC AIR SUPPLY Push in 8 tubing LUBRICANT EXIT 6 3 co axial 4 Mono tubing PUMP STROKE ADJUSTMENT AIR FLOW REGULATIOR ELECTRIC LEVEL FILLER PLUG SOLENOID CABLE GLAN...

Page 11: ...electronic tank and base structure must be connected to the ground line see paragraph 6 7 Flammability The oil employed in the lubrication circuit is not normally flammable It is nonetheless indispen...

Page 12: ...The operator coming into contact with fluid due to breakage opening of supply tubing The operator must be furnished with suitable personal protection clothing equipment according to current regulation...

Reviews: