DROPSA VIP4ToolsPro User And Maintenance Manual Download Page 1

 

 

VIP4Tools

Pro

 

Minimal air/oil system lubrication 

 
User and  
Maintenance Manual 
 

Original Text Translation 

 
 

TABLE OF CONTENTS 
 

 

1. 

 

INTRODUCTION 

2. 

 

GENERAL DESCRIPTION 

3. 

 

PRODUCT IDENTIFICATION 

4. 

 

TECHNICAL CHARACTERISTICS 

5. 

 

DESCRIPTION OF COMPONENTS 

6. 

 

INSTALLATION 

7. 

 

INSTRUCTIONS FOR USE 

8. 

 

MAINTENANCE 

9. 

 

DISPOSAL 

10.   

ORDERING INFORMATION 

11.   

DIMENSIONS 

12.   

HANDLING AND TRANSPORTATION 

13.   

PRECAUTION IN USE 

14.   

CONTRAINDICATIONS 

 

 

 

 

 

 

 

 

 

 

 

 

http://www.dropsa.com

 

Via Benedetto Croce, 1 

Vimodrone, MILANO (IT) 

t. +39 02 250791 

 

Dropsa products can be purchased from Dropsa branches and authorized distributors, 

visit 

www.dropsa.com/contact or contact us [email protected] 

 

The manual has been prepared in compliance with Directive             C2121IE WK 51/15 
CE 06/42 

Summary of Contents for VIP4ToolsPro

Page 1: ...STRUCTIONS FOR USE 8 MAINTENANCE 9 DISPOSAL 10 ORDERING INFORMATION 11 DIMENSIONS 12 HANDLING AND TRANSPORTATION 13 PRECAUTION IN USE 14 CONTRAINDICATIONS http www dropsa com Via Benedetto Croce 1 Vim...

Page 2: ...mmediately replaced After long periods of inactivity check air tightness of all parts subjected to pressure Personnel must use personal protection equipment clothing and tools adequate for the locatio...

Page 3: ...re 10 C 80 C 14 F 176 F Maximum switching power 50 W 5 V Maximum current 1 A Maximum voltage 220 V AC 5 DESCRIPTION OF COMPONENTS Central VIP4ToolsPro Unit The central unit of the lubrication system i...

Page 4: ...r on components subject to vibration Only use the supplied mounting bracket with N 2 holes for 6 mm 0 23 in bolts 6 3 MOUNTING THE MINI PUMPS ON THE MIXER BASES for replacement or augmenting The mini...

Page 5: ...ecifications 6 6 1 Schematic electrical connection Samba Level NC electric level in the absence of lubricant 6 6 2 Schematic electrical solenoid connection Connector 39979 EV 24 V DC non polarized N B...

Page 6: ...6 EXAMPLE OF TUBING AND NOZZLE CONNECTION STRAIGHT TUBING CO AXIAL TUBING CONNECTION...

Page 7: ...s to an increase in flow of 5 mm until reaching 30 mm at the 7th turn see table FLOW mm stroke TURNS 30 6 5 25 5 5 20 4 5 15 3 5 10 2 5 5 1 5 0 no pump delivery Completely unscrewed 7 4 OUTLET AIR FLO...

Page 8: ...rder that any leaks will be immediately evident When necessary replace the oil filling filter P N 3130139 Periodically empty the pressure regulator condensate trap by rotating the small red valve loca...

Page 9: ...rication Points with pneumatic timer 3 Liters 24V AC 50 60Hz 3704320 2 Lubrication Points with pneumatic timer 3 Liters 24V AC 50 60Hz 3704330 3 Lubrication Points with pneumatic timer 3 Liters 24V AC...

Page 10: ...IR FLOW REGULATOR SOLENOID VALVE 24 V DC AIR SUPPLY Push in 8 tubing LUBRICANT EXIT 6 3 co axial 4 Mono tubing PUMP STROKE ADJUSTMENT AIR FLOW REGULATIOR ELECTRIC LEVEL FILLER PLUG SOLENOID CABLE GLAN...

Page 11: ...electronic tank and base structure must be connected to the ground line see paragraph 6 7 Flammability The oil employed in the lubrication circuit is not normally flammable It is nonetheless indispen...

Page 12: ...The operator coming into contact with fluid due to breakage opening of supply tubing The operator must be furnished with suitable personal protection clothing equipment according to current regulation...