11 

13. HANDLING AND TRANSPORT 

 

Prior  to  dispatch  VIP

4

Air  lubrication  panels  are  carefully  packed  in  a  cardboard  carton.  During  transportation  and  storage 

maintain the equipment the right way up as indicated on the carton.  
On receipt, check that the packaging is not damaged and store the equipment in a dry place. 
Given the lightness of the unit, lifting devices are not required for its handling. The box is fitted with suitable handling devices. 

 
 

14. PRECAUTIONS IN USE 

 

It is necessary to carefully read the warnings and the risks involved in using the lubrication panel. The operator must understand 
the functioning of the unit by studying  the user’s manual. 

 

Electric currents 

No  intervention  must  be  attempted  on  the  equipment  without  first  having  disconnected  the  electrical  power  supply  and 
ensuring that it cannot be reconnected during the intervention. 
All  installed  equipment,  electrical,  electronic,  tank  and  base  structure,  must  be  connected  to  the  ground  line  utilizing  the 
terminals fitted to each component. 

Flammability 

The oil employed in the lubrication circuit is not normally flammable. It is nonetheless indispensable to take every precaution 
against the oil coming into contact with very hot parts or open flames.  

Pressure 

Prior to any intervention on the equipment ensure that pressure is released from all branches of the lubrication circuit. Failure 
to do this could result in oil being discharged under pressure where connections or components are disassembled 

Noise 

The VIP

4

Air lubrication panel does not emit excessive noise, remaining below 70dB(A). 

 

WARNING:

 before carrying out the replacement of the mini-pumps, empty the tank of lubricant. 

 

15. CONTRAINDICATIONS 

 
The VIP

4

Air panel does not have any particular contraindications except for the following points: 

 

The operator coming into contact with fluid due to breakage/opening of supply tubing. 

The operator must be furnished with suitable personal protection clothing/equipment. 

 

Abnormal posture. 

Take note of the indications shown in 

paragraph 10.2.

 

 

Contact with oil during filling/maintenance. 

 

Use of unsuitable lubricants. 

Main inadmissible fluids. 

 

Fluid 

Danger 

Lubricants with abrasive additives 

High wear rate of contacted parts 

Lubricants with silicon based additives 

Seizure of the pump 

Petrol – solvents – flammable liquids 

Fire – explosion – damage to seals 

Corrosive products 

Corrosion of the pump– injury to persons 

Water 

Oxidation of the pump 

Food substances 

Contamination of the substances themselves 

 
16. WARRANTY INFORMATION 

 

All  Dropsa  products  are  supplied  with  a  12  month  guarantee  against  defects  in  manufacture  or  materials.  The  guarantee  is 
available  to  whoever  has  possession  of  the  product  during  the  period  in  question.  The  guarantee  covers  all  repairs  or 
replacement of the product. These functions will be carried out exclusively on the premises of Dropsa.  
The guarantee will be null and void where the product: 

-

 

has not been mounted/assembled in accordance with the manufacturer’s instructions 

-

 

has been modified or tampered with. 

Excluded from the guarantee are all those parts subject to normal wear, such as seals, tubing, etc.  
The guarantee period starts on the date of original purchase. 
Dropsa SpA declines any responsibility from injury to persons or animals or damage to property where the installation, use or 
maintenance has not been carried out in accordance with the instructions in this manual. 

Summary of Contents for VIP4Air Series

Page 1: ...NERAL DESCRIPTION 3 PRODUCT MACHINE IDENTIFICATION 4 TECHNICAL SPECIFICATIONS 5 MACHINE COMPONENTS 6 UNPACKING AND INSTALLING THE MACHINE 7 INSTRUCTIONS FOR USE 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 OPERATING HAZARDS 15 PRECAUTIONS 16 WARRANTY INFORMATION 17 DECLARATION OF COMPLIANCE WITH STANDARDS 18 DROPSA LO...

Page 2: ...uate for the location and the use of the panel both during its operation and during maintenance operations The panel and any accessories mounted on it should be carefully checked immediately on receipt and in the event of any discrepancy or complaint the Dropsa SpA Sales department should be contacted without delay Dropsa SpA declines to accept any responsibility for injuries to persons or damage ...

Page 3: ...ly and a solenoid valve which can block the air flow the VIP4Air panel manages and controls the entire lubrication process the time intervals the lubrication flow rate the air pressure and the oil level In addition it provides for priming cycles air venting Pneumatic Mini pump The mini pumps employed are particularly small and are installed on the mixer bases They can be fitted with a range of spa...

Page 4: ...cal connection completely integrated into the mixer base with the VIP4Air panel mounted on the central unit Where an anomaly occurs this is detected by the central unit which signals the error The functioning is also indicated by an LED mounted on the base itself When the VIP4Air starts a lubrication cycle the LED located on the mixer base illuminates ON until the end of the lubrication cycle Duri...

Page 5: ...es for Ø6 mm bolts 6 3 MOUNTING THE MINI PUMPS ON THE MIXER BASES for replacement or augmenting The mini pumps are mounted on the mixer bases utilizing two securing screws Particular attention should be paid to the correct positioning of the o rings between the mini pump and the mixer base see diagram below 6 4 MOUNTING THE DOSER ASSEMBLY ON THE PUMP for replacement or augmenting To install a new ...

Page 6: ...ns Note The female connector is purchased separately see Accessories N B After all connections have been completed ensure the tubing and cables are protected from impacts and are suitably secured 7 INSTRUCTIONS FOR USE 7 1 STARTING THE VIP4Air PANEL Before using the VIP4Air panel it is necessary to carry out some preliminary checks check the integrity of the equipment check that the electrical and...

Page 7: ...he pump The range of regulation is 0 0 9 9 seconds Enter the desired values using the and keys 1 5 s Pause cycle Interval of time between one lubrication cycle and the next The count commences when the delivery of lubricant is confirmed Range of regulation is 00 00 99 59 minutes Enter the desired values using the and keys User discretion Inversion of solenoid command Relay function 1 for NC 0 for ...

Page 8: ... out Priming verifying the delivery of lubricant at the outlet o Flow sensor defective Check the sensor electrical connections or replace it o Check the oil level in the tank o Check the pressure on the display and regulate it on the external reducer To facilitate the operation press and hold down the key to freeze the air pressure display The alarm depends on the value entered during set up o Che...

Page 9: ...isconnected before undertaking any maintenance tasks 10 DISPOSAL During the maintenance of the machine or in the event of its being scrapped do not discard polluting components in the environment Refer to local regulations for their correct disposal At the time of final disposal of the machine it is necessary to destroy the identification plate and all other documentation 11 ORDERING INFORMATION V...

Page 10: ...10 15 DIMENSIONS Number of elements Height A mm Weight Kg 1 331 3 8 2 359 4 3 3 387 4 8 4 415 5 3 5 448 5 8 6 471 6 3 7 499 6 8 8 527 7 3 Tube Air input Tube Ø 6 ...

Page 11: ... out the replacement of the mini pumps empty the tank of lubricant 15 CONTRAINDICATIONS The VIP4Air panel does not have any particular contraindications except for the following points The operator coming into contact with fluid due to breakage opening of supply tubing The operator must be furnished with suitable personal protection clothing equipment Abnormal posture Take note of the indications ...

Page 12: ...IP4AIR è conforme alle condizioni previste dalle Direttive CEE has been constructed in conformity with the Directives Of The Council Of The European Community on the standardization of the legislations of member states a été construite en conformité avec les Directives Du Conseil Des Communautes Europeennes Entsprechend den Richtlinien des Rates Der Europäischen Union für die Standarisierung der L...

Page 13: ...uk dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerling Hts Mi Us USA Tel 1 586 566 1540 Fax 1 586 566 1541 E mail salesusa dropsa com Dropsa Lubrication Systems Nr 8 Dongxing Road Songjiang Industrial Zone Shanghai Co Ltd Tel 86 021 67740275 Fax 86 021 ...