7
Stage 2 – Initial function - Set-up
Press the MODE key for 10 seconds to enter the configuration menu. All the basic functions necessary for the correct
functioning of the equipment are entered during this Set-up function. To regulate see the paragraph on regulation.
Stage 3 – Normal function
On switching on the cycle is automatically activated. During the pause time the display shows alternately the time
remaining of the cycle and the mixer air pressure. At the same time the LEDs at the side of the display are
illuminated alternately.
By pressing the
↑
key it is possible to freeze the display of the mixer air pressure reading until the key is released.
By pressing the
↓
key it is possible to freeze the display of the timer reading until the key is released.
Stage 4 – Alarm function
In the alarm mode the display starts blinking displaying the error code (see the “troubleshooting” paragraph).
When the conditions have been restored, the RESET button must be pressed to return to normal functioning.
7.3 REGULATION
To regulate all the parameters, start the pump and press the MODE key for 5 seconds. Subsequently follow the
instructions given in the table below.
Pressing the MODE key passes from one option to the next.
PARAMETERS
DISPLAY
DESCRIPTION
OPERATION
DEFAULT
Cycle control
time
The max. time is set within which the delivery of
lubricant must be confirmed. The range of regulation is
00-60 seconds
Enter the desired values using the
↑ and ↓ keys
5 s
Pump recharge
time
Pause time for recharging the pump. The range of
regulation is 0.0-9.9 seconds.
Enter the desired values using the
↑ and ↓ keys
1.5 s
Pause cycle
Interval of time between one lubrication cycle and the
next. The count commences when the delivery of
lubricant is confirmed. Range of regulation is
00.00-99.59 minutes.
Enter the desired values using the
↑ and ↓ keys
User
discretion
Inversion of
solenoid
command
Relay function;
1
for NC,
0
for NO.
Do not alter
1
N° of control
elements
Number of elements installed with flow control. If the
value 0 is set, before entering in pause (pause time), all
the timeout time must pass. Range of regulation 0-99
elements.
Enter the desired values using the
↑ and ↓ keys
Min. 1
Max. 8
Max. air
Max. limit of mixer air pressure. Entering the value 0 the
alarm is disabled. Range of regulation 0.0-7.0 bar
Enter the desired values using the
↑ and ↓ keys
User
discretion
Min. air
Min. limit of air pressure. Range of regulation 0.0-7.0
bar.
Enter the desired values using the
↑ and ↓ keys
User
discretion
Minimum oil
level
Alarm function for minimum oil level.
Entering the value 0 an error is
displayed but the VIP
4
Air
continues to operate.
Entering the value 1 an error is
signaled and the equipment stops.
1
System start pre-
cycle
Number of start cycles for system pre-lubrication. Range
of regulation 00-60.
Enter the desired values using the
↑ and ↓ keys bearing in mind
that the value of cycles entered
must be double that of the desired
value.
6
Cycles of fault
Number of consecutive fault cycles needed for an alarm.
Enter the desired values using the
↑ and ↓ keys.
2
Alarm Status
Set the action to take after an alarm:
1
= stop the lubrication cycles
0
=Do not stop the lubrication cycles
Enter the desired values using the
↑ and ↓ keys.
1