5
6.
UNPACKING AND INSTALLING THE PUMP
6.1 UNPACKING
Once a suitable location has been found to install the unit, remove the pump from package. Check the unit has
not been damaged during transportation or storage. No particular disposal procedures are necessary as
package materials are no dangerous for health or environment. However, package should be disposed of in
accordance with regulations that may be in force in your area or state.
6.2 INSTALLING THE PUMP
In order to facilitate any maintenance intervention, to avoid unnatural posture for personnel during
machine operation or the possibility of sustaining impacts, install the machine in a comfortable and
easy-to-reach location.
Allow sufficient space for the installation, leaving minimum 100 mm (3.9 in.) around the unit.
Do not install the unit in aggressive or explosive/inflammable environments or on vibrating surfaces.
To install the pump, use only the supplied bracket provided with two holes for Ø6 mm (Ø 0.2 in.)
screws (see
Dimensions, ch. 12
).
6.3 HYDRAULIC CONNECTION
Connect
SMART2
to the system via the hydraulic connection located on the baseplate, on the right side of the
pump: standard thread ¼ BSP.
6.4 ELECTRIC WIRING
6.4.1 ELECTRIC DIAGRAM
Here follows the general electric diagram for both automatic and manual
SMART2
:
NOTICE: Pressure can be monitored by a micro-switch or a NPN/PNP proximity sensor.
6.4.2 USER CONNECTIONS
The following picture shows PCB user interface, where the user has to connect power supply and external
outputs for the correct functioning of both automatic and manual
SMART2
. For details about connections,
please refer to special paragraphs.
(PCB serigraphy only refers to automatic SMART2).
PCB user connections
only refers to automatic
SMART2
M1
M2