6
6. UNPACKING AND INSTALLATION
6.1 UNPACKING
Once you have identified the suitable place for installation, open the package and remove the pump and check that it has
not suffered any damages during transport and storage. The packing material does not require special disposal
precautions as it is in no way dangerous or pollutant. For disposal, refer to local regulations.
6.2 INSTALLATION OF PUMPING ELEMENTS / CAPS
The pumping elements are not included in the pump, they must be purchased separately by selecting the appropriate part
numbers. The caps are included in the packaging; to be inserted into the holes that are not being used by the pumping
elements.
To assemble the pumping elements, proceed as follows:
Locate the correct position by distributing them evenly over the holes on the pumping element holder cylinder.
No
.
MOUNTING POSITIONS
No
.
MOUNTING POSITIONS
No
.
MOUNTING POSITIONS
1
1
13
13
25
25
2
1-7
14
13-19
26
25-31
3
1, -5, -9
15
13, -17, -21
27
25, -29, -33
4
1-4-7-10
16
13-16-19-22
28
25-28-31-34
5
1-2-4-7-10
17
13-14-16-19-22
29
25-26-28-31-34
6
1-3-5-7-9-11
18
13-15-17-19-21-23
30
25-27-29-31-33-35
7
1-2-4-5-7-9-11
19
13-14-16-17-19-21-23
31
25-26-28-29-31-33-35
8
1-2-4-5-7-8-10-11
20
13-14-16-17-19-20-22-23
32
25-26-28-29-31-32-34-35
9
1-2-3-5-6-7-9-10-11
21
13-14-15-17-18-19-21-22-23
33
25-26-27-29-30-31-33-34-35
10
1-2-3-4-5-6-7-9-10-11
22
13-14-15-16-17-18-19-21-22-23
34
25-26-27-28-29-30-31-33-34-35
11
1-2-3-4-5-6-7-8-9-10-11
23
13-14-15-16-17-18-19-20-21-22-23
35
25-26-27-28-29-30-31-32-33-34-35
12
1-2-3-4-5-6-7-8-9-10-11-12
24
13-14-15-16-17-18-19-20-21-22-23-24
36
25-26-27-28-29-30-31-32-33-34-35-36
Positioning of pumping elements
36