7. PUMP OPERATION  

 

7.1 COMMISSIONING THE PUMP  

 

The unit can only be opened and repaired by authorized Dropsa personnel.

 

 

Do not use the pump submerged in fluids, in aggressive environments such as close to extremely hot 
substances, flammable or explosive material whether the supplier has not specifically prepared the 
pump for it. 

 

 

Always wear safety glasses and gloves when working with pneumatic and hydraulic systems.

 

 

Do not use abrasive lubricants with gaskets NBR. In the event of doubts, contact the Dropsa technical 
centre that will provide all details on indicated lubricants.

 

 

Do not ignore hazards for health and observe hygienic rules.

 

 

Always use tubing suited for the specific working pressure. 

 

 
 
 

Before using the pump, it is necessary to perform some preliminary checks: 

 

Check the integrity of the pump; ensure there is no physical damage. 

 

Fill the Oil reservoir with suitable lubricant (see instructions min/max on the reservoir). 

 

Check the pump working temperature and ensure there is no trapped air within tubing. 

 

Check electrical connections have been carried out correctly (CEI 64/8, IEC 364). 

 

Check level control panel connections and their operating status. 

 

 

7.2 USING THE PUMP 

 

 

Check set data on the panel. 

 

Push the start button of the machine to which the pump is connected. 

 Check 

pump 

commissioning. 

 

Ensure the machine is properly lubricated (in the event of doubts, contact the Dropsa technical centre to 
request the testing procedure. 

 

  
 
 
 

8. TROUBLESHOOTING  

 

The following table highlights some of the most common problems encountered when using the 
Locopump and how to resolve them.  
In the event of doubts or problems not listen, do not dismantle the pump but contact a DropsA technical 
centre for assistance. 
 

DIAGNOSTIC TABLE  

PROBLEM 

 

The pump starts but does not 
deliver lubricant or delivers 
different quantities from the 
required discharge.  
 
 
 
 
The pump does not deliver 
lubricant at the set pressure or 
does not keep the working 
pressure.

 

PROBABLE CAUSE  

 

o

  The reservoir has insufficient oil.

o

 

The control valve does not 
discharge. 

 

o

  Fittings may have become lose. 

o

 

Incorrect adjustment of the 
control inlet air pressure. 

 

o

 

The check valve may be 
damaged or clogged.  

 

 

SOLUTION 

 

o

  Fill the oil reservoir. Do not 

exceed the max. level. 

 

o

  Check the pump control valve 3 

ways is normally discharging 
compressed air.  

 

o

  Tighten any loose fittings on the 

pump or the lubrication system. 

 

o

  Adjust properly the air pressure 

within the established range of 
pressures considering the 
compression ratio.  

 

o

  Clean or change the valve 

(chapter 6.6 point F) which is 
comprised in the kit 3132671  
 

 

 

Summary of Contents for LOCOPUMP

Page 1: ...TECHNICAL CHARACTERISTICS 5 PUMP COMPONENTS 6 UNPACKIGING AND INSTALLING THE PUMP 7 PUMP OPERATION 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDL...

Page 2: ...with valve UNI 7663 shape A 1 8 NPT Lubricant outlet G 1 4 bsp Compressed air inlet G 1 8 bsp compression cone seating 6 mm 0 2 in tube Cartridge shaped filter positioned at the grease gun inlet Elec...

Page 3: ...onfiguration is N C 6 UNPACKING AND INSTALLING THE PUMP WARNING The unit can only be opened and repaired by authorized Dropsa personnel 6 1 UNPACKING Once a suitable location has been found to install...

Page 4: ...aulic connectors are placed on the front face of the pump body The pump outlets are threaded as standard with 1 4 BSP threads 6 5 SUPPLY CONNECTION Use a fitting of 1 8 BSP to connect the pump Dropsa...

Page 5: ...ck set data on the panel Push the start button of the machine to which the pump is connected Check pump commissioning Ensure the machine is properly lubricated in the event of doubts contact the Drops...

Page 6: ...nent remove and clean them Before mounting each component has to be washed in oil and lubricate The following routine operations should be performed Operation Interval in hours Check correct lubricati...

Page 7: ...NDLING AND TRANSPORTATION Pumps are accurately packed and dispatched in cardboard containers During transportation and storage always maintain the pump the right way up as indicated on the box On rece...

Page 8: ...ions has been carried out filling in checking lists provided and contained in the technical file Dropsa used two kind of checking lists The list of hazards according to the EN 1050 as it refers to EN...

Page 9: ...aid receipt of subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will perf...

Page 10: ...UMATIC PUMP 36003XX o Has been manufacturer in conformance with the European Community Directive relating to the harmonised standards of the member states relating to machine safety EMC 89 336 CEE and...

Page 11: ...563 100 07 Fax 55 011 563 194 08 E mail salesbr dropsa com Dropsa S p A Via B Croce 1 20090 Vimodrone MI Italy Tel 39 02 250 79 1 Fax 39 02 250 79 767 E mail sales dropsa it Export E mail vendite drop...

Reviews: