DROOFF Kaminöfen —
Feuer aus dem Sauerland
TECHNICAL INFORMATION
Page 21
w w w . d r o o f f - k a m i n o f e n . d e
ROOM-hEATInG CAPACITy
Room-heating capacity in m
3
4 kW
8 kW
Heat requirement
suitable
62
182
less suitable
39
105
unsuitable
25
71
According to DIN 18893, the above mentioned room volumes apply for rooms which do not
comply with the legislation on thermal insulation. Lower capacities are sufficient for rooms
of the above volumes which comply with the legislation on thermal insulation.
APPROvED FUEl TyPES
n
Dry untreated logs with a maximum residual moisture content of 19% measuring 30 cm
(max.) in length and approx. 10 cm in diameter.
n
Wood briquettes
n
Lignite briquettes
FUEl QUAnTITIES
Depending on the quality of the fuel, the chimney and the weather conditions, it will take
approx. 30-45 minutes for one stoking of fuel to burn down. When it has burned down to the
red embers, the stove can be re-stoked.
REGUlATInG ThE AIR InFEED
Secondary air (marked P)
Open = slide knob at I
Closed = slide knob at 0
Primary air (marked S)
Open = slide knob at I
Closed = slide knob at 0
Air valves
Quantity
logs
Wood Briquettes lignite Briquettes
For 4 kW approx.:
1.0 kg/h
1.0 kg/h
-
Per stoke approx.:
0.8 kg
0.8 kg
-
For 8 kW approx.:
2.1 kg/h
2.1 kg/h
1.7 kg/h
Per stoke approx.:
1.6 kg
1.6 kg
1.7 kg