HeatPack Furnace Installation and Operation Manual
51
10.5 Manual or thermostat control
From factory, the opening and closing of the air inlet damper is manually activated by the
means of a switch located at the rear of the furnace. The switch has two positions; opened
and closed.
Position of the air control rod when the switch in
the “closed” position (-).
For added comfort, the installation of an optional wall thermostat is recommended since it
will open the air inlet damper when the room temperature is below the set point of the
thermostat and will close the air inlet damper as the desired temperature is reached (see
Appendix 1: Optional thermostat installation
).
If the heat sensors detect any overheating in the air jacket of the furnace, the air inlet
damper will close automatically regardless of the type of control used.
The thermostat mode will work properly only if the air control damper switch is in
closed position.
10.6 Ash drawer
Your furnace is equipped with an ash drawer to collect ashes produced by the combustion
of wood. The ash drawer is provided with two (2) wing nuts to hold the door in a close
position. Operating the furnace with the ash drawer open may seriously damage the
furnace.
The drawer must be emptied regularly.
Summary of Contents for HeatPack DF00500
Page 29: ...HeatPack Furnace Installation and Operation Manual 29...
Page 64: ...HeatPack Furnace Installation and Operation Manual 64 13 Exploded diagram and parts list...
Page 65: ...HeatPack Furnace Installation and Operation Manual 65...
Page 66: ...HeatPack Furnace Installation and Operation Manual 66...
Page 67: ...HeatPack Furnace Installation and Operation Manual 67...
Page 68: ...HeatPack Furnace Installation and Operation Manual 68...
Page 69: ...HeatPack Furnace Installation and Operation Manual 69...
Page 75: ...HeatPack Furnace Installation and Operation Manual 75 14 2 1 Technical data HeatPack...
Page 76: ...HeatPack Furnace Installation and Operation Manual 76...