4.3 Non-authorized installation configuration
4.3.1 Non-authorized installation configuration in Canada and United States
•
The hot air distribution duct of the
furnace
(A)
must not be installed in the
air return duct of the furnace
(B)
.
•
The hot air distribution duct
(B)
must not
be installed in the air return duct of the
furnace
(A)
.
5 Positioning the unit and clearances to combustible
materials
To reduce the risk of vibration, the furnace must be leveled in both directions and
supported evenly to ensure stability.
5.1 Unit positioning
The furnace must be installed where outside air supply will be sufficient for proper
combustion. If required, a fresh air return adaptor kit (sold separatly) can be installed to
supply combustion air to the room or space.
The furnace must be positioned so that the flue pipe is as short as possible. Minimize the
use of 90° elbows.
The owner must ensure a proper installation to allow a safe operation of the appliance.
The owner must ensure cleanliness of the room in the event of negative pressure or
temporarily negative pressure.
5.2 Certification label
WARNING
THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE
INSTRUCTIONS ON THE CERTIFICATION LABEL APPLIED ON THE UNIT.
Summary of Contents for HeatPack DF00500
Page 29: ...HeatPack Furnace Installation and Operation Manual 29...
Page 64: ...HeatPack Furnace Installation and Operation Manual 64 13 Exploded diagram and parts list...
Page 65: ...HeatPack Furnace Installation and Operation Manual 65...
Page 66: ...HeatPack Furnace Installation and Operation Manual 66...
Page 67: ...HeatPack Furnace Installation and Operation Manual 67...
Page 68: ...HeatPack Furnace Installation and Operation Manual 68...
Page 69: ...HeatPack Furnace Installation and Operation Manual 69...
Page 75: ...HeatPack Furnace Installation and Operation Manual 75 14 2 1 Technical data HeatPack...
Page 76: ...HeatPack Furnace Installation and Operation Manual 76...