S7

 - Standard, no XIO option installed. 

HV

 - Ten Digital Inputs, presets for 24VAC, 120VAC, or 240VAC. 

Six Digital Outputs, 24VAC to 240VAC, 0.5A with ZVS. 

CL

 - Sixteen 4-20mA inputs. 

Eight 4-20mA outputs. 

Eight digital out/in, separate source up to 24VDC, 300mA shared. 

XD

 - Sixteen digital inputs, 3V to 30V logic with 5V and 24V enumeration. 

Sixteen digital outputs/inputs, separate source up to 24VDC, two 

300mA shared banks. 

XA

 - Four separately-isolated, milliVolt analog inputs w/ 5V excitation and 

cold-junction compensation for load-cell, thermocouples, RTDs, 2V max. 

Terminal Type 

P

 - Plug-in screw terminals; six blocks of  10 terminals; 60 total. See page 4. 

Mounting 

D, S, F, A, 4 

D

 - DIN rail edge mounting without flex clip. 

S

 - DIN rail side, flat mounting using standard clips. 

F

 - Flex mounting; DIN rail edge or DIN rail flat with flex clip. 

A

- Spacer mounting with four bolt holes, see page 5. 

4

 - NEMA4X enclosed. 

smarty

7

 

Installation

smarty

 

is designed for permanent installation by qualified professionals.

Install

 

smarty

 in metal enclosure with no RF noise source.

 

DIN rail mounting 

- Use 35x7.5mm rail per IEC 60715 or EN50022.

 

Environment 

- UL/IEC Pollution Degree 2. 

Operating temperature, 0°C min., 40°C max.  

Storage temperature, -20°C to 50°C. 

Altitude 3000m max.  

Humidity 95% max. non-condensing.  

Clearances 

must be provided all around to promote airflow, 5mm (0.2”) sides, 

25mm (1”) above and below. 

smarty

7

 

Terminal Naming and Ratings

Terminal names are consistent in the 

drive.web savvy

 software, on 

the terminal, and on the cover plate next to the terminal.  

24VDC  and  0V

  Terminals  are  internally  connected. 

Regulated DC Supply, 25.2Vmax, 22.8Vmin, 1A.  

External

 

1A fast-acting fuse or current-limiting is required!

  

Do not connect to a distributed DC power network.  

Supply  from  Class  2,  LPS,  limited  power  supply,  from 

within the same electrical enclosure, only. 

AI

 - Analog inputs. -11VDC to +11VDC, 100k

Ω

, 1kHz, 16-bit. Also 

configurable for 5V or 24V logic digital input. 30V max. 

AO

 - Analog outputs. Bipolar, -10.5VDC to +10.5VDC. 10mA. 

DI

 - Digital inputs. 50VDCmax, 8VDC threshold, 3V hysteresis. 1kHz. 

Configurable as event inputs. 

DO

 - Digital outputs. 24VDC source, up to 300mA, shared. 

Resistive, general use, and pilot duty. Overcurrent protection 

and software indication. Also configurable as digital inputs. 

Maximum Voltage is 25.2VDC. 

smarty

 

HG504266Iss1.0

 

 

www.driveweb.com

              

              

Page  /12

3

Summary of Contents for smarty7 dw250

Page 1: ...e undesired operation This Class A digital apparatus is designed to comply with Canadian ICES 003 Cet appareil numerique de la classe A est conforme la norme NMB 003 du Canada Warning It is essential...

Page 2: ...Y THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAG...

Page 3: ...ource DIN rail mounting Use 35x7 5mm rail per IEC 60715 or EN50022 Environment UL IEC Pollution Degree 2 Operating temperature 0 C min 40 C max Storage temperature 20 C to 50 C Altitude 3000m max Humi...

Page 4: ...ers Fast transient over Voltage 1kV per EN 61000 4 4 Signal Wiring Notes Use twisted pair wiring for encoder and serial differential signals Outside metal enclosure use shielded cable with individuall...

Page 5: ...Modbus A 2 0V 3 CAN 4 CAN 5 0V 6 Modbus B 1 2 3 4 5 6 24V 0V FT1 FT2 FT3 FT4 FT5 FT6 TO7 5V 24V 0V DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 24V 0V DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 2B 2B 2A 2A 1B 1B 1A 1A 0V 24...

Page 6: ...ctory due to shipping restrictions smarty7 Frequency Input Notes FI Terminals FI Digital and Event Input Function Blocks Maximum event frequency is 1 2 FBE cycle s Hz E g for 5ms FBE cycle the max eve...

Page 7: ...a 2b 1a is converted from hexadecimal to decimal 26 2b similarly is 43 decimal The as shipped address is 10 189 26 43 Use Category 5e cable or better with 8P8C RJ 45 connectors for each drive web devi...

Page 8: ...of the drive If the icon at right appears a network connection problem exists Check connections LEDs and that the smarty IP address is within the computer s Ethernet subnet mask Warning Importing data...

Page 9: ...Coupons offline To upgrade savvy go to the Commerce menu select Upgrade savvy check desired options click OK To upgrade smarty choose Upgrade Device in its contextual menu check desired options click...

Page 10: ...emo with savvy Select File Demo Mode Discover Internet Demo DevicessavvyPanel Pages Systems Page where multiple savvyPanel systems are present A savvyPanel system may contain tiles from many drive web...

Page 11: ...er manual for detailed instructions Launch savvyPanel via command line or batch file Limit operators to savvyPanel only Specify start system and page Discover devices automatically specifically by dis...

Page 12: ...meter IDs mapping to PLC5 Supports up to two simultaneous clients ModbusRTU M Master Client S Slave Server X None See pages 2 and 4 Modbus Function Codes FC 01 through 06 and 16 are supported Also spe...

Reviews: