background image

drive.web automation

Warning! 

Avoid permanent damage to your 

smarty

, never exceed any 

min

 or 

max

 values.  Do not connect 

any 

smarty

 terminal to mains circuits. See page 5 for IO ratings.

 

lwIP is incorporated into 

smarty

 firmware. lwIP Copyright (c) 2001-2004 Swedish Institute of  Computer Science. All rights reserved. 

Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met: 

1. Redistributions of  source code must retain the above copyright notice, this list of  conditions and the following disclaimer. 

2. Redistributions in binary form must reproduce the above copyright notice, this list of  conditions and the following disclaimer in the documentation and/or 

other materials provided with the distribution. 

3. The name of  the author may not be used to endorse or promote products derived from this software without specific prior written permission. 

THIS  SOFTWARE  IS  PROVIDED  BY  THE  AUTHOR  “AS  IS''  AND  ANY  EXPRESS  OR  IMPLIED  WARRANTIES,  INCLUDING,  BUT  NOT 

LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN 

NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL 

DAMAGES  (INCLUDING,  BUT  NOT  LIMITED  TO,  PROCUREMENT  OF  SUBSTITUTE  GOODS  OR  SERVICES;  LOSS  OF  USE,  DATA,  OR 

PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT 

LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN 

IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. 

Product Identification - 

smarty

7

The 

smarty

7

 dw25x

 Series are Universal Automation Controllers (

UAC

Find 

smarty

 model and firmware version. Use 

savvy

Get Detailed 

Info

 from 

smarty

 contextual menu. See page 6.  

Product Identification - Part Numbers

Model number

 

dw25x 

is appended with a three character extension. 

   

Example; 

dw250-DM-S7PF

               

Model

    

ModbusRTU Type

      

Terminal Type

               

 

               

Build Standard

           

XIO Build (2 characters)

  

Mounting

      

 

smarty

7

 

Models

 

dw250

 

Universal Automation Controller, 

(

UAC

). 

dw254

 

UAC

 for 

P2

  industrial vector drive. 

dw258

 

UAC

 for 

E3

 open-loop vector drive. 

dw259

 

UAC

 for 

CANopen

 server devices. 

Build Standard 

A, B, C,

 and 

D

 - Software Options 

 

A

=04 and 26, 

B

 adds 05 and 25, 

C

 adds 06 and 39, 

D

 adds 10 and 29. 

04 ModbusTCP/IP

 - Server-slave.

 

See page 12. 

05 Process Control

 - Recommended for most applications. 

06 Winder Control

 - Diameter Calc., Taper Tension, Torque Comp. 

10 Math

 - With advanced math functions.

 

 

25 EIP/PCCC

 - Slave/server. See page 12. 

26 

savvyPanel

 - Operator station interface. See pages 8, 9. 

29 Solar 

-

 

Calculates sun position azimuth and zenith. 

39 Precision Motion 

-

 

With event, length, position, shaft-lock,  

indexing, motion control, cam profile, and more. Page 12. 

ModbusRTU Type, Options 

M, S, X 

M

 - ModbusRTU Client-Master with speeds up  to 500kbps. See page 12 

S

 - ModbusRTU Server-Slave. Read or write any parameter in the 

device remotely. See page 12. 

X

 - No ModbusRTU capability.

smarty

 

HG504266Iss1.0

 

 

www.driveweb.com

              

              

Page  /12

2

{

{

Summary of Contents for smarty7 dw250

Page 1: ...e undesired operation This Class A digital apparatus is designed to comply with Canadian ICES 003 Cet appareil numerique de la classe A est conforme la norme NMB 003 du Canada Warning It is essential...

Page 2: ...Y THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAG...

Page 3: ...ource DIN rail mounting Use 35x7 5mm rail per IEC 60715 or EN50022 Environment UL IEC Pollution Degree 2 Operating temperature 0 C min 40 C max Storage temperature 20 C to 50 C Altitude 3000m max Humi...

Page 4: ...ers Fast transient over Voltage 1kV per EN 61000 4 4 Signal Wiring Notes Use twisted pair wiring for encoder and serial differential signals Outside metal enclosure use shielded cable with individuall...

Page 5: ...Modbus A 2 0V 3 CAN 4 CAN 5 0V 6 Modbus B 1 2 3 4 5 6 24V 0V FT1 FT2 FT3 FT4 FT5 FT6 TO7 5V 24V 0V DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 24V 0V DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 2B 2B 2A 2A 1B 1B 1A 1A 0V 24...

Page 6: ...ctory due to shipping restrictions smarty7 Frequency Input Notes FI Terminals FI Digital and Event Input Function Blocks Maximum event frequency is 1 2 FBE cycle s Hz E g for 5ms FBE cycle the max eve...

Page 7: ...a 2b 1a is converted from hexadecimal to decimal 26 2b similarly is 43 decimal The as shipped address is 10 189 26 43 Use Category 5e cable or better with 8P8C RJ 45 connectors for each drive web devi...

Page 8: ...of the drive If the icon at right appears a network connection problem exists Check connections LEDs and that the smarty IP address is within the computer s Ethernet subnet mask Warning Importing data...

Page 9: ...Coupons offline To upgrade savvy go to the Commerce menu select Upgrade savvy check desired options click OK To upgrade smarty choose Upgrade Device in its contextual menu check desired options click...

Page 10: ...emo with savvy Select File Demo Mode Discover Internet Demo DevicessavvyPanel Pages Systems Page where multiple savvyPanel systems are present A savvyPanel system may contain tiles from many drive web...

Page 11: ...er manual for detailed instructions Launch savvyPanel via command line or batch file Limit operators to savvyPanel only Specify start system and page Discover devices automatically specifically by dis...

Page 12: ...meter IDs mapping to PLC5 Supports up to two simultaneous clients ModbusRTU M Master Client S Slave Server X None See pages 2 and 4 Modbus Function Codes FC 01 through 06 and 16 are supported Also spe...

Reviews: