b) The room must also have a system that allows for normally. The flow of air
needed for combustion must not be less than 2 m3/h per KW of installed power.
The air circulation system may take air directly form the outside by means of a
pipe with an inner cross section of at least 100 cm2; the opening cannot under
any circumstances be blocked accidentally(Fig A), The system can also provide
the air needed for combustion by indirect means. i.e. form adjacent rooms fitted
with air circulation tubes as described above. However, these rooms must be
common rooms, bedrooms or rooms with a fire hazard( Fig. B)
Details A
Adjacent Room
Room to be ventilated
Fig A Fig B
c) Liquefied petroleum gas is heavier than air and, therefore, settles downwards.
Thus, rooms containing LPG cylinders must also be equipped with apertures to
the outside for ventilation of gas in the event of leaks. LPG cylinders must not,
therefore, be installed or stored in rooms or storage areas that are below ground
level(cellars, etc.) whether they are partially or completely full. It is a good idea to
keep only the cylinder being used in the room, positioned so that it is not subject
to heat produced by external sources (ovens, fireplaces, stoves, etc.) which
could raise the temperature of the cylinder to the above 50.
Prior to installation, ensure that the local distribution conditions (nature of the gas
and gas pressure), and the adjustment of the appliance are compatible.
The adjustment conditions for this appliances are stated on the label(or data plate)
This appliance is not connected to a combustion products evacuation device. It shall
be installed and connected in accordance with current installation regulations.
Particular attention shall be given to the relevant requirement regarding ventilation.
Installation of Build-in Ovens
In order to ensure that build-in appliance functions properly, the cabinet containing it
must be appropriate. The figure below gives the dimensions of the cut-out for
installation under the counter or in a wall cabinet unit.