background image

 

Product Safety Statement 

Intended Use 

Use of Drifton equipment in ways other than those described in the documentation supplied with the 
equipment may result in injury to persons or damage to property. Some examples of unintended use of 
equipment include:  

 

Using incompatible materials  

 

Making unauthorized modifications  

 

Removing or bypassing safety guards or interlocks  

 

Using incompatible or damaged parts  

 

Using unapproved auxiliary equipment  

 

Operating equipment in excess of maximum ratings  

 

Operating equipment in an explosive atmosphere  

Regulations and Approvals 

Make sure all equipment is rated and approved for the environment in which it is used. Any approvals 
obtained for Drifton equipment will be voided if instructions for installation, operation and service are not 
followed.  

Qualified Personnel 

Equipment owners are responsible for making sure that Drifton equipment is installed, operated and serviced 
by qualified personnel. Qualified personnel are those employees or contractors who are trained to safely 
perform their assigned tasks. They are familiar with all relevant safety rules and regulations and are 
physically capable of performing their assigned tasks.  

Personal Safety 

To prevent injury, follow these instructions: 

 

Do not operate or service equipment unless you are qualified 

 

Keep  clear  of  moving  equipment.  Before  adjusting  or  servicing  moving  equipment,  shut  off  the 
power supply and wait until the equipment comes to a complete stop. Lock out power and secure the 
equipment to prevent unexpected movement.  

 

Make sure dispensing areas and other work areas are adequately ventilated. 

 

Know where emergency stop buttons, shutoff valves and fire extinguishers are located. 

 

Clean  –  Remove  all  electrical  and  mechanical  connections  to  unit.  Apply  a  small  amount  of  light 
detergent onto a moist cloth and wipe surface of unit lightly, cleaning any stains or spilled adhesive.  

 

Maintain – Only use clean dry air and regulated power supply to unit.  Equipment does not require 
any other regular maintenance. 

 

Test  –  Verify  operation  of  features  and  performance  of  equipment  using  the  ‘Testing  and 
installation’  sections  within  this  Operation  manual.  If  necessary,  refer  to  the  ‘Trouble  Shooting 
Guide’  elsewhere  in  this  user  guide.  A  faulty  or  defective  unit  should  be  returned  to  Drifton  or 
representative for refurbishment. 

Caution

: Use replacement parts that are designed for use with original equipment, so that our dispenser will 

work according to specifications. 

 

Summary of Contents for 206-DAB Series

Page 1: ...90 FAX 0045 3677 3633 Website www drifton eu www drifton d E mail info drifton dk Drifton Double Syring Liquid Dispenser Operation Manual GB Drifton 206 DAB Drifton 206 DAB ES 1201 1 1 Drifton 206 DAB ES 1202 2 1 Drifton 206 DAB ES 1203 4 1 Drifton 206 DAB ES 1204 10 1 ...

Page 2: ...nded testing procedures Review the helpful information we have included which is based on more years of industrial dispensing experience Most questions you will have are answered in this Operation Manual However if you need assistance please do not hesitate to contact Drifton A S at telephone 0045 5372 8090 or info drifton dk or an authorized distributor Our goal is to build not only the finest eq...

Page 3: ... Approvals 4 Qualified Personnel 4 Personal Safety 4 Started 5 Principles 5 Dispenser Hookup 6 Drifton 206 DAB Double Syringe Dispenser 7 Specifications 7 Connections drawing 7 Controls Panel 8 Valve 8 Setup for Testing 9 Suggestions on Settings 9 Troubleshooting Guide 10 Guarantee 11 ...

Page 4: ...cally capable of performing their assigned tasks Personal Safety To prevent injury follow these instructions Do not operate or service equipment unless you are qualified Keep clear of moving equipment Before adjusting or servicing moving equipment shut off the power supply and wait until the equipment comes to a complete stop Lock out power and secure the equipment to prevent unexpected movement M...

Page 5: ...ent dispensers Next We will tell you how to dispense low viscosity fluid using the vacuum control and how to dispense high viscosity liquid Principles Drifton double liquid dispenser series quotes air pressure to control liquid fluid dispensing through high precision timing of pressure pulse control which ensures that the correct amount of fluid is applied every time on every part to every item Ti...

Page 6: ...he valve to the dispenser The other tube assembly into the front of the dispenser 6 Take the liquid material and fill the barrel Insert the piston down into the barrel 7 Take the barrel and attach the valve fixate it and then attach the mixing Nozzle If you want to have a small volume you can connect the needle 8 Note Always use the lowest possible pressure and the largest possible tip size The co...

Page 7: ...S 1S 0 1S 10S 0 2S 20S Air Input 7 KgF cm2 Dry air without lubrication Air Output 0 1 7KgF cm2 Repeatability tolerance 0 5 Min depot 0 05ml Input Voltage 110V 220V 10 50Hz Output Voltage 24V Power 15W Connections drawing Foot pedal switch Power line Air input hose Adapter assembly Male quick connect Valve 1000J Double barrel ...

Page 8: ...t receptacle Air input connector Foot pedal switch finger switch Air exhaust port Valve Installation of the double barrel Using the vacuum suction function recover the piston rod cylinder loosen the fixing screws and unloaded ring put the double barrel into the ring and then insert the valve tightening the screws with fix Bar Fixing screw ...

Page 9: ...ot pedal switch and liquid will flow out When you stop stepping on the foot pedal it will stop dispensing glue Fifth Press the Auto button Turn the Timer knob clockwise Adjusting range 0 01 1 00s 0 1 10s 0 2s 20s Sixth Be sure barrel vacuum control is turned off The vacuum volume should be 0 when testing If you want to test vacuum suction take some water in the barrel first and fasten the tip then...

Page 10: ...tor is turned off fully counterclockwise If dispensing high viscosity materials try increasing output air pressure slightly Vacuum level is set to high Barrel adapter safety clip may be clamped shut Inconsistent dispense output Check the dispensing tip barrel and material for possible contamination or clogs Note Dispensing System Components are disposable Do not attempt to reuse Check for air supp...

Page 11: ...ntability or fitness for a particular purpose In no event shall Drifton be liable for incidental or consequential damages The following situations are not in the scope of warranty users should pay the maintenance costs 1 The mistake of operation or transport causes damage to the machine by the user 2 Replace the components or repair the machine by a repairer which is not designated by the manufact...