background image

10 

 

Troubleshooting Guide 

A Drifton Customer Service or Technical Services representative is always available to assist you with any 
question you may have about your Dispensing System. Please feel free to call or email us at the addresses on 
the front cover of this manual book. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trouble 

Solution 

No fluid being 
dispensed 

 

Check the power supply connection and DC power supply to the 
unit. 

Check the main air supply and primary regulator. 

Check to make sure that the main air supply is connected to the back 
of the unit and has not come loose. 

Check to make sure that the regulator is turned off (fully 
counterclockwise) 

If dispensing high viscosity materials, try increasing output air 
pressure slightly. 

Vacuum level is set to high. 

Barrel adapter safety clip may be clamped shut. 

Inconsistent 
dispense output 

 

Check the dispensing tip, barrel and material for possible 
contamination or clogs. 

Note: Dispensing System Components are disposable. Do not 
attempt to reuse. 

Check for air supply pressure fluctuation. 

Air bubbles in the fluid path and entrapped air within the fluid may 
cause inconsistency. For best dispensing results, remove all 
entrapped air before dispensing. 

Vacuum level is set to high. 

Barrel adapter safety clip may be clamped shut. 

Material suck-back 

Always use an appropriate piston to prevent material from being 
drawn back into the dispenser. 

Summary of Contents for 206-DAB Series

Page 1: ...90 FAX 0045 3677 3633 Website www drifton eu www drifton d E mail info drifton dk Drifton Double Syring Liquid Dispenser Operation Manual GB Drifton 206 DAB Drifton 206 DAB ES 1201 1 1 Drifton 206 DAB ES 1202 2 1 Drifton 206 DAB ES 1203 4 1 Drifton 206 DAB ES 1204 10 1 ...

Page 2: ...nded testing procedures Review the helpful information we have included which is based on more years of industrial dispensing experience Most questions you will have are answered in this Operation Manual However if you need assistance please do not hesitate to contact Drifton A S at telephone 0045 5372 8090 or info drifton dk or an authorized distributor Our goal is to build not only the finest eq...

Page 3: ... Approvals 4 Qualified Personnel 4 Personal Safety 4 Started 5 Principles 5 Dispenser Hookup 6 Drifton 206 DAB Double Syringe Dispenser 7 Specifications 7 Connections drawing 7 Controls Panel 8 Valve 8 Setup for Testing 9 Suggestions on Settings 9 Troubleshooting Guide 10 Guarantee 11 ...

Page 4: ...cally capable of performing their assigned tasks Personal Safety To prevent injury follow these instructions Do not operate or service equipment unless you are qualified Keep clear of moving equipment Before adjusting or servicing moving equipment shut off the power supply and wait until the equipment comes to a complete stop Lock out power and secure the equipment to prevent unexpected movement M...

Page 5: ...ent dispensers Next We will tell you how to dispense low viscosity fluid using the vacuum control and how to dispense high viscosity liquid Principles Drifton double liquid dispenser series quotes air pressure to control liquid fluid dispensing through high precision timing of pressure pulse control which ensures that the correct amount of fluid is applied every time on every part to every item Ti...

Page 6: ...he valve to the dispenser The other tube assembly into the front of the dispenser 6 Take the liquid material and fill the barrel Insert the piston down into the barrel 7 Take the barrel and attach the valve fixate it and then attach the mixing Nozzle If you want to have a small volume you can connect the needle 8 Note Always use the lowest possible pressure and the largest possible tip size The co...

Page 7: ...S 1S 0 1S 10S 0 2S 20S Air Input 7 KgF cm2 Dry air without lubrication Air Output 0 1 7KgF cm2 Repeatability tolerance 0 5 Min depot 0 05ml Input Voltage 110V 220V 10 50Hz Output Voltage 24V Power 15W Connections drawing Foot pedal switch Power line Air input hose Adapter assembly Male quick connect Valve 1000J Double barrel ...

Page 8: ...t receptacle Air input connector Foot pedal switch finger switch Air exhaust port Valve Installation of the double barrel Using the vacuum suction function recover the piston rod cylinder loosen the fixing screws and unloaded ring put the double barrel into the ring and then insert the valve tightening the screws with fix Bar Fixing screw ...

Page 9: ...ot pedal switch and liquid will flow out When you stop stepping on the foot pedal it will stop dispensing glue Fifth Press the Auto button Turn the Timer knob clockwise Adjusting range 0 01 1 00s 0 1 10s 0 2s 20s Sixth Be sure barrel vacuum control is turned off The vacuum volume should be 0 when testing If you want to test vacuum suction take some water in the barrel first and fasten the tip then...

Page 10: ...tor is turned off fully counterclockwise If dispensing high viscosity materials try increasing output air pressure slightly Vacuum level is set to high Barrel adapter safety clip may be clamped shut Inconsistent dispense output Check the dispensing tip barrel and material for possible contamination or clogs Note Dispensing System Components are disposable Do not attempt to reuse Check for air supp...

Page 11: ...ntability or fitness for a particular purpose In no event shall Drifton be liable for incidental or consequential damages The following situations are not in the scope of warranty users should pay the maintenance costs 1 The mistake of operation or transport causes damage to the machine by the user 2 Replace the components or repair the machine by a repairer which is not designated by the manufact...

Reviews: