Dri-Eaz Sahara ProX3 115V Owner'S Manual Download Page 1

DRI-EAZ PRODUCTS, INC.

 

15180 Josh Wilson Road, Burlington, WA USA 98233

 

Fax: (360) 757-7950  Phone US: (360) 757-7776 

 

www.dri-eaz.com

 

Owner’s Manual  

Sahara ProX3  (115V Model)

 

Patents: 

http://www.LBpatents.com

 

  

READ AND SAVE THESE INSTRUCTIONS 

 1 

P

LACING

 Y

OUR

 T

URBO

D

RYERS

 

When drying the interior of a building, use at least one TurboDryer 

per water-damaged room, or one every 200 square feet.

 

Try to get 

airflow to all wet surfaces. Open interior doors to improve air circula-

tion, and brace doors to prevent them from blowing shut.

 

 

 

 

 

 

Do not move or carry a TurboDryer while under operation. When the unit 

is in motion, the powerful airflow is hard to control, and can produce 

rapid and unpredictable movement.

 

Do not allow children to play with or around TurboDryers. If they lift or 

get a unit off balance, the powerful airflow can cause the TurboDryer to 

move rapidly, risking injury.

  

Do not alter or modify your Dri-Eaz product in any way. Use only re-

placement parts authorized by Dri-Eaz Products, Inc. Modifications or 

use of unapproved parts could create a hazard and will void your war-

ranty. Contact your authorized Dri-Eaz distributor for assistance. 

O

PERATING

 Y

OUR

 T

URBO

D

RYER

 

1. Locate the electrical cord and plug into a standard 3-prong outlet. 
2. Set the switch to the desired speed, based on amp draw as listed 

by the switch on the side control panel.  

 
T

HE

 A

UXILIARY

 O

UTLET

 

You can “daisy chain” or interconnect up to three Sahara Pro X3 units 

to customize your drying needs. The unit can conduct a maximum of 

12 amps when it is turned off or 8 amps when it is turned on.  
 
R

ED

 C

IRCUIT

 B

REAKER

 S

WITCH

 

The primary purpose of the circuit breaker is to protect the machine. It 

turns the unit off when more than 12 amps are run through the on-unit 

circuit.                           
 

G

ROUND

 F

AULT

 C

IRCUIT

 I

NTERRUPTER

 

The GFCI protects the user. Should it detect a sudden “ground fault,” 

the GFCI will interrupt the electric current. The GFCI will also trip 

when a short circuit or overload occurs. If the GFCI “trips,” unplug the 

unit and look for potential hazards (standing water, frayed cord, etc.) 

that might cause an electrical surge. Relocate the unit and plug into a 

different outlet. Then push the “Reset” button and check to make sure 

it is operating. If so, continue use; if not, call a Dri-Eaz tech specialist 

at 800-575-5152. 

WARNING

  

ELECTRIC SHOCK HAZARD

  

This unit must be electrically 
grounded 
Use only on GFCI protected  
receptacles  

The power cord is equipped with a 3-
prong grounding plug. 

Use only with 

a matching receptacle.

  

Do not cut off the grounding prong.  
Do not use an adapter.  
Do not use with a damaged power 
cord. 
Do not use an extension cord.  
To reduce risk of fire or electric shock, 
do not use this airmover with any solid
-state speed control device. 

 

WARNING 

07-01537D F351-120V 2013-05  Warranty 07-00419 

Dri-Eaz Products, Inc. 

NOTE:

 

Humidity will rise with the use of 

TurboDryers because they lift moisture 
from wet materials into the air.

 

To learn 

about managing humidity during drying, 
contact your local distributor or call Dri-
Eaz Education at 800-575-5152.

 

Summary of Contents for Sahara ProX3 115V

Page 1: ...ahara Pro X3 units to customize your drying needs The unit can conduct a maximum of 12 amps when it is turned off or 8 amps when it is turned on RED CIRCUIT BREAKER SWITCH The primary purpose of the c...

Page 2: ...ray the rag then apply to the surface To renew shine on the plastic use a vinyl cleaner Remove grill and blower then blow off internal components with compressed air ANNUALLY Inspect components and in...

Page 3: ...wheel 4 Pull the blower wheel out of the unit 1 2 3 4 3 To remove control panel and motor Rotate the unit onto its side so that the controls are facing up 5 Unscrew 2 screws securing cord guard 2 Phil...

Page 4: ...ating Cut offs Dual Thermal Protectors Safety Marks UL cUL listed Power 4 amps Cord Length 25 ft 7 6 m Housing Polyethylene Troubleshooting For any problems not listed below call your local distributo...

Page 5: ...rticulares de secado La unidad puede conducir hasta un m ximo de 12 amperios cuando est apagada y 8 amperios cuando est en cendida INTERRUPTOR ROJO DEL CORTACIRCUITOS El principal objetivo del cortaci...

Page 6: ...dos ANUALMENTE Examinar los componentes y los cables internos en busca de decolora ci n conexiones sueltas o desgastes ANTES DE CADA USO Examine el cable de alimentaci n por si ha se ha cortado gastad...

Page 7: ...del soplador de la unidad 1 2 3 4 3 Para retirar el panel de control y el motor Coloque la unidad de costado de manera que los controles est n hacia arriba 5 Desatornille los 2 tornillos que fijan el...

Page 8: ...Alimenta ci n 4 amp Largo del cable 7 6 m 25 ft Carcasa Polietileno Soluci n de problemas Para cualquier problema que no aparezca en la lista llame a su distribuidor local o comun quese con el Depar t...

Page 9: ...areil est de 12 amp res lors qu il est teint et de 8 amp res lorsqu il est allum COMMANDE ROUGE DU DISJONCTEUR La raison d tre principale du disjoncteur est de prot ger l appareil Il teint l ap pareil...

Page 10: ...avec un nettoyant a rosol tout usage Vaporiser un torchon et appliquer sur la surface de l appareil Pour faire briller le plastique employer un nettoyant pour le vinyle Enlever la grille filtre ventur...

Page 11: ...de ventilation de l appareil 1 2 3 4 3 Fa on d enlever le tableau de commande et le moteur Mettre l appareil sur le c t afin que les commandes soient sur le dessus 5 Enlever les 2 vis qui retiennent...

Page 12: ...Carter Poly thyl ne D pannage Pour toute difficult qui ne figure pas dans la liste ci dessous communiquer avec le distributeur local ou avec notre service la client le au 888 867 3235 PROBL ME CAUSE S...

Reviews: