background image

07-01913H F515-115V 

Dri-Eaz Products, Inc. 

 

Owner’s Manual 

PHD 200 Dehumidifier 

Model F515-115V 

DRI-EAZ PRODUCTS, INC.  

15180 Josh Wilson Road, Burlington, WA 98233 

Phone: 800-932-3030

 

Fax: 360-757-7950  

The Dri-Eaz

®

 PHD 200 Dehumidifier reduces humidity in enclosed environments by removing water vapor 

from the air. The PHD 200 is ideal for crawlspace drying, humidity control and other applications requiring 
high-performance dehumidification. (Not intended for professional water damage restoration.) 

Patents: http://www.LBpatents.com 

S A V E   T H E S E   I N S T R U C T I O N S

 

 

 

 

 

 

 

 

 

 

SAFETY INSTRUCTIONS 

WARNING! Do not alter or modify your unit in any 
way. Use only replacement parts authorized by 
Dri-Eaz Products, Inc. Modifications or use of unap-
proved parts could create a hazard and will void 
your warranty. Contact your authorized distributor 
for assistance. 

WARNING! Electric shock hazard, rotating fan, hot 
surface hazards. Unplug unit before opening cover 
for cleaning or servicing. Unit must be grounded. 

  Inspect the power cord before use. If cord is dam-

aged, do not use. Always grasp the plug (not the 
cord) to unplug. 

  Insert three-prong plug on power cord into a match-

ing electrically grounded outlet. Do not use adapter. 
Never cut off third prong. Do not use an extension 
cord.  

  The unit must be operated on a 115V/60Hz circuit 

protected by a Ground Fault Circuit Interrupter 
(GFCI) device.  

  Keep motor and wiring dry. 

  Do not attempt to repair the unit. For Authorized 

Service Centers, contact Dri-Eaz.  

BEFORE YOU BEGIN 

Warranty registration 

Visit 

warranty.drieaz.com

 to register your purchase. 

Registration allows us to better assist you with using, 
maintaining or servicing your equipment and to contact 
you in case we have important safety information con-
cerning your Dri-Eaz product. If you determine service is 
required, have your equipment model, serial number and 
original proof of purchase available and call your distrib-
utor for assistance with obtaining a return material au-
thorization (RMA). 

 

INTRODUCTION 

The PHD 200 Dehumidifier reduces humidity in enclosed 
structural environments by removing water vapor from 
the air. With proper use, the PHD 200 can help to dry out 
damp structural materials, insulation, and contents, and 
maintain a healthy level of humidity. Using the PHD 200 
may also prevent secondary damage caused by high hu-
midity. 

WARNING

 

CORRECT PLUG REMOVAL 

Grasp IEC plug and pull straight out

 

IMPORTANT:  Damage  to  IEC  receptacle  or  dehu-
midifier  resulting  from  improper  removal  of  the 
power  cord  is  not  covered  by  warranty.  The  IEC 
power  cord  is  a  wear  item  and  is  not  covered  by 
warranty.

 

Summary of Contents for PHD 200

Page 1: ...use adapter Never cut off third prong Do not use an extension cord The unit must be operated on a 115V 60Hz circuit protected by a Ground Fault Circuit Interrupter GFCI device Keep motor and wiring d...

Page 2: ...f you use a bucket or other container for water collection check it regularly to prevent over flows NOTICE Uncoil and straighten the entire drain hose Do not leave any part of the hose coiled and do n...

Page 3: ...sary and the machine will begin operation immedi ately DISPLAY MENU Press to cycle through the display of additional dehumidifier conditions and User Settings To return to the main menu press the ON O...

Page 4: ...T OUTLET 100 80 115 30 For information only 3 GRAIN DPR XX GPP XX X g kg for 230V models 4 FILTER CLEANED XXX HRS 5 FILTER CLEANED 0 HRS Press to clear filter hours 5 COIL CLEANED XXX HRS 5 COIL CLEAN...

Page 5: ...urfaces falls into the sump area 3 Press the PURGE key When the purge cycle is complete turn the unit off 4 Remove the external drain hose drain it carefully coil it and secure it with one of the stra...

Page 6: ...splay the following messages when the Pump Purge Button is pressed C O N T R O L P A N E L M E S S A G E E X P L A N A T I O N PUMP PURGING XX Pump is purging with countdown in seconds Press key again...

Page 7: ...L M E S S A G E E X P L A N A T I O N A N D S O L U T I O N ER4 DEFROST SENSOR CONNECT or ER4 OULET SENSOR CONNECT Temp sensor is open missing or shorted Check that temp sensors are installed cor rec...

Page 8: ...firm humidity level with hygrometer Increase room temperature Check filter Clean or replace as necessary Check heat exchange block and coils Clean as necessary If the problem you are experiencing is n...

Page 9: ...debe utilizarse en un circuito el ctrico de 115 V 60 Hz protegido por un interruptor del circuito de fallos de conexi n a tierra GFCI por sus siglas en ingl s No utilice el aparato en agua estancada M...

Page 10: ...a 3 pies 1 m por encima de la parte inferior de la unidad Tambi n vea si hay torceduras u otras obstrucciones que podr an restringir el flujo de agua Las obstrucciones pueden provocar una retenci n de...

Page 11: ...humidistato Consulte la secci n Men de configuraci n del usuario PURGE PURGA Presione para vaciar el agua del dep sito de la bomba de condensado En la pantalla aparecer PURGING PUMP PURGANDO BOMBA co...

Page 12: ...2 ENTRADA SALIDA 100 80 115 30 S lo para informaci n 3 ENTRADA SALIDA XX X g kg 4 FILTRO LIMPIAR XXX HR 5 FILTRO LIMPIAR 0 HRS Presione para borrar las horas de limpieza del filtro 5 LIMPIAR BOBINA X...

Page 13: ...rrala con cuidado enr llela y suj tela con una de las tiras al costado de la unidad TRANSPORTE Y ALMACENAMIENTO AVISO Manipule la unidad con cuidado No la tire ni la apoye en lugares donde pueda caers...

Page 14: ...lesiones a los ocupantes del veh culo PROGRAMA DE MANTENIMIENTO ADVERTENCIA PELIGRO DE DESCARGA EL C TRICA Desconecte la unidad antes de limpiarla o darle mantenimiento ADVERTENCIA Riesgo de exposici...

Page 15: ...o de versi n del firmware del tablero de con trol Ninguna FXXX XXX N mero de modelo Ninguna APAGADO La unidad ha terminado de encender y est funcionando Ninguna POR FAVOR ESPERE RETAR COMPRS XX 60s de...

Page 16: ...en el panel de control Si el error persiste comun quese al centro de servicio ER5 CONEXION SENSOR TABLERO Sensor de temperatura humedad relativa de entrada abierto faltante o en cortocircuito Comprue...

Page 17: ...est lleno El bloque de intercambio de calor y o los serpentines est n tapados Controle el nivel de humedad con un higr metro Aumente la temperatura de la habitaci n Controle el filtro L mpielo o reemp...

Page 18: ...est endommag Pour d brancher toujours saisir la prise et non le cordon Enfoncer les trois fiches de la prise du cordon dans une prise de courant mise la terre Ne pas utiliser d adaptateur Ne jamais s...

Page 19: ...s au dessus du fond de l appareil V rifier galement s il existe des plis ou autres ob stacles susceptibles de limiter le d bit d eau Les obstructions peuvent causer des d bordements Brancher le cordon...

Page 20: ...RQUE Si aucun compte rebours pour le compresseur n est affich un d lai n est pas n cessaire et l appareil commencera fonctionner imm diatement MENU D AFFICHAGE Appuyer pour faire d filer l affichage p...

Page 21: ...IDA 100 80 115 30 Pour information seulement 3 ENTRADA SALIDA XX X g kg 4 FILTRO LIMPIAR XXX HR 5 FILTRO LIMPIAR 0 HRS Appuyer sur pour effacer les heures du filtre 5 LIMPIAR BOBINA XXX HRS 5 LIMPIAR...

Page 22: ...e dans le puisard 3 Appuyez sur la touche PURGE Lorsque le cycle de purge est termin teignez l unit 4 Retirez le tuyau de vidange externe videz le soigneusement enroulez le et maintenez le en place l...

Page 23: ...ompe avec un chiffon humide Inspecter la base de la pompe pour l ac cumulation de d bris et nettoyer si n cessaire D visser le raccord cannel et le clapet anti retour et rincer le rac cord et le clape...

Page 24: ...HIGROSTATO ENTRADA XXX C XX Premi re ligne indique que l unit est en mode hygros tat Seconde ligne Alterne entre la temp rature d entr e et RH d entr e toutes les 2 secondes Aucune BAJA TEMP ENTRADA X...

Page 25: ...ur le panneau de commande Si l er reur persiste contacter le fournisseur de services ER5 CONEXION SENSOR TABLERO Le capteur de la temp rature Rh d entr e est ouvert manquant ou court circuit V ri fier...

Page 26: ...s bobines sont bouch es V rifier le niveau d humidit avec un hygrom tre Augmenter la temp rature ambiante V rifier le filtre Le nettoyer ou le remplacer si n cessaire V rifier bobines Les nettoyer si...

Reviews: