49-120A 2014-12 Warranty 07-00424
2
Dri-Eaz Products, Inc.
OVERVIEW
The Dragon 3600 Mobile Furnace is an indirect fired
heater. This design keeps combustion air separate from
heated air and allows the Dragon to heat air without
adding any moisture, fumes or smoke.
The Dragon should always be operated outdoors, and
should utilize outside air for combustion. An electric fan
directs this heated air into the structure through ducting.
The remote thermostat automatically cycles the Dragon
on and off to maintain a preset temperature in the target
area.
Principles of Use
The clean, dry heat from the Dragon helps reduce drying
times while maintaining stable and comfortable
temperatures. The Dragon is ideal for wide range of
applications, including
water damage restoration
new construction drying
unheated jobsites
temporary event shelters
workshops, storage rooms, and warehouses
greenhouses and polyurethane tunnels for
agriculture
any situation calling for clean, dry temporary heat
For use in water damage restoration and new
construction drying, the Dragon can increase drying
efficiency. The added heat from the Dragon will increase
the rate of evaporation by decreasing the relative
humidity of the affected area. Raising the temperature of
a drying area with the Dragon from 60° to 70°F can
increase the evaporative potential of your existing drying
system up to 45 percent.
For best results when using the Dragon for restoration,
you should understand the basic principles of structural
drying. You can learn these skills and more in an IICRC-
certified Applied Structural Drying (ASD) course. To
learn more about ASD courses, contact the Restoration
Science Academy at 800-932-3030.
GROUNDING INSTRUCTIONS
The Dragon 3600 Mobile Furnace is designed to
operate
on a 115V/60 Hz electrical connection. The unit
requires 7.5 amps. Make sure that the electrical outlet is
grounded with three prongs. Use with a grounded
extension cord intended for outdoor use and rated to
deliver enough power to the Dragon.
WARNING! Improper connection of the equipment-
grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or service
person if you are in doubt as to whether the outlets
are properly grounded. Do not modify the plugs
provided with the appliance – if the plugs do not fit
the outlets, have proper outlets installed by a
qualified electrician.
This equipment is for use on circuits with a nominal
rating of no more than 120V.
This unit is intended for household and commercial use.
HANDLE THE UNIT CAREFULLY
Always operate the unit on a stable, level surface. Do
not drop, throw, or place where it could fall. Rough
treatment can damage the unit, and may create a
hazardous condition or void the warranty.
Control panel
Fuel drain under
tank (not shown)
Air adjustment
dial
Fig. A: Parts Identification
Air intake
Flue opening (stack
not shown)
Handle
Heated air outlet
and duct ring
Fuel filter
Fuel level sight
Fuel fill and cap
Weather shield
Burner reset
access panel.