49-120A 2014-12 Warranty 07-00424
6
Dri-Eaz Products, Inc.
Note
: T
he most common cause of thermal overload
is restricted airflow.
To help prevent thermal overload,
you should
Make ducting runs as straight and short as
possible
Keep the ducting unobstructed and free of
debris
Keep the air intake grill unobstructed
MAINTENANCE
NOTICE: Always turn unit off and unplug before
performing any maintenance.
D E S C R I P T I O N
I N T E R V A L
1. Clean the fuel tank.
Yearly
2. Replace the fuel filter.
As needed/Yearly
3. Service the burner, heat
exchanger, and combustion
chamber.
Yearly.
HVAC technician only.
4. Clean the housing
As needed/Yearly
1. Clean the fuel tank.
a. Place an appropriate container beneath the drain
plug to catch any fuel.
b. Remove the drain plug with a wrench.
c. Allow the tank to drain completely.
d. Replace the drain plug.
e. Dispose of waste fuel in accordance with local
regulations.
WARNING! Diesel fuel is flammable and potentially
explosive. Always turn off and unplug the Dragon
before draining the fuel tank. Keep away from open
flame.
2. Replace the fuel filter
Replace the fuel filter once a year. Unscrew the filter to
remove it. Replacement fuel filters may be purchased
from most automotive supply retailers. Ask for Wix
®
part.
no. 24104 or equivalent. Have rags or paper towels on
hand to clean up any spills, and dispose of the filter and
waste fuel according to local regulations.
3. Service the burner, heat exchanger and
combustion chamber
This components should be inspected and serviced by a
qualified HVAC technician once a year. Contact your
local distributor for the location of a service center near
you.
4. Clean the housing
Use a cleaner with a degreasing agent such as
Unsmoke Degrease-All to clean the housing as needed.
Service
For parts and service contact your local distributor.
Copies of the Dragon manual and related information
are available at
www.Dri-Eaz.com.
Go to
warranty.Dri-Eaz.com
to register your purchase.
Accessories Included
1 25 ft. (7.6 m) section of 12 in. (30 cm) high-
temperature ducting.
1 Hinged buckle ducting clamp
1 50 ft. (15.3 m) thermostat sensor cable with sensor.
1 Exhaust stack and rain cap
1 Owner’s Manual
SPECIFICATIONS
Model
Dragon 3600 Portable Heater
F535
Dimensions, including
trailer (W × H × D)
65 × 43 × 24 in.
1.9 × 1.4 × 3.0 m
Weight (empty)
250 lbs. | 113 kg
Weight (full)
495 lbs. | 225 kg
Power
7.5 amps, 115 volt, 60 Hz
Net heat output
120,000 BTU/hr | 29.3 kWh
Airflow
680 CFM w/Weather Sheild
780 CFM w/out Weather Sheild
Fuel tank capacity
32 gal. | 208 liter maximum
Fuel type
No. 1 or no. 2 diesel or fuel oil.
Fuel consumption rate
.85 gal./hr | 3.1 liter/hr
Fuel pump pressure
140 psi | 966 kPa
Specifications are subject to change without notice. Some
values may be approximate.