3.  Locate the pump assemble and remove the four bolts con-

necting it to the drain pan (Fig. 5). Lift the pump free. DO 
NOT DISCONNECT ANY INTERNAL ELECTICAL 
CABLES.  

4.  Remove the two bolts holding the pump to the pump brack-

et (Fig. 6). Set bracket aside. 

5.  Locate the impeller housing on the bottom of the pump as-

sembly. Remove the impeller housing by prying apart one 
of the two tabs with a screwdriver (Fig. 7). Once one tab is 
released, the housing will come loose and the second tab is 
easily released.  

6.  Inspect the impeller and the housing for dirt and debris. 

Wipe clean with a cloth. Use a cotton swab to clean the 
blades of the impeller.  

7.  Reattach the impeller housing to the pump assembly.  Be-

fore snapping the housing into place, make sure the O-ring 
is in position (Fig. 8) and make sure the housing is properly 
aligned as shown (Fig. 9). The drain line and the electrical 
cable should be pointing in the same direction. 

8.  Inspect the drip tray. Wipe clean with a cloth as necessary. 

9.  Reattach the pump assembly to the pump bracket using the 

two bolts.  

10. Inspect the coil for dust accumulation. Vacuum excess 

dust, taking care not to damage any components. Clean 
coils with Dri-Eaz Coil Cleaner. Be sure to wipe up any 
spills.  

11. Inspect the filter. Clean in mild soap and water and dry tho-

roughly before reinstalling into the filter panel.  

12. Replace the drain line panel. Make sure the drain line is 

free of kinks and sharp bends before tightening the screws.  

13. Replace the interchangeable panels.   

14. Test the CMC100 for proper operation. For operation in-

structions, see your Owner’s Manual. 

 

NOTE: Before returning the CMC100 to use, make sure it is 
properly leveled and that the end of the drain hose is no more 
than 3 ft. (1 m) above the top of the CMC100. See “Keep Unit 
Level,” p. 2, for instructions.

 

 

Fig. 7: Use a screwdriver to pry open 
the impeller housing retaining tabs.  

Fig. 9: Reassemble impeller as shown. Make 
sure electrical cables are oriented in the 
same direction as the drain tube.  

Fig. 6: Remove the pump from the pump 
bracket. 

Fig. 8: Make sure O-ring is correctly seated 
before reassembling impeller.  

Summary of Contents for CMC100

Page 1: ...ord to unplug The unit must be operated on a 115V 60 Hz circuit protected by a Ground Fault Interrupter GFI device This appliance is not intended for use by persons includ ing children with reduced physical sensory or mental ca pabilities or lack of experience and knowledge unless they have supervision or have been given instruction con cerning use of the appliance by a person responsible for thei...

Page 2: ... steady stream or not at all for short periods of time These functions indicate normal dehumi difier and pump purge operations NOTICE To avoid spills always secure the end of the drain hose so that the intermittent pumping action doesn t shift the hose out of position NOTICE Do not allow the outlet of the drain hose to become submerged blocked or otherwise subject to pressure that might reduce the...

Page 3: ...n you press the UP or DOWN buttons Af ter you have finished adjusting the setting the display will resume indicating the measured humidity and the CMC will automatically maintain humidity at the selected setting 2 In the STANDBY mode the display shows a double dash Unit does not operate in this mode Press the ON STANDBY button to return to ON mode Note The UP and DOWN buttons do not function in th...

Page 4: ...able filter Inspect the filter by removing the four filter door screws and sliding it out of the filter door panel see Figure 2 If the filter shows excessive buildup vacuum it clean and wash it in mild detergent Replace the filter in the filter door and close the door securely Note Do not operate the unit without the filter securely in place If the filter becomes torn or can no longer be adequatel...

Page 5: ...n 8 Inspect the drip tray Wipe clean with a cloth as necessary 9 Reattach the pump assembly to the pump bracket using the two bolts 10 Inspect the coil for dust accumulation Vacuum excess dust taking care not to damage any components Clean coils with Dri Eaz Coil Cleaner Be sure to wipe up any spills 11 Inspect the filter Clean in mild soap and water and dry tho roughly before reinstalling into th...

Page 6: ...ice Some values may be approximate PARTS INCLUDED WITH THE CMC Four leveling feet with mounting hardware 10 feet 3 meters of drain hose One hose clamp for attaching drain hose ADDITIONAL PRODUCT INFORMATION and current docu mentation is available at http cmc 100 dri eaz com FOR PARTS AND SERVICE CALL YOUR LOCAL DISTRIB UTOR or the Dri Eaz Service Department at 800 932 3030 www dri eaz com Visit wa...

Reviews: