MAINTENANCE 

WARNING! 

Unplug unit before cleaning or servicing. 

Note: 

Protect from freezing. Freezing may damage unit.  

Note: 

Check filter one month after first installation for any initial 

buildup of dust or debris, and clean as needed. See “Inspect 
and Clean Filter Element” below. 

 

MONTHLY MAINTENANCE 

Inspect Power Cord  

Inspect power cord for cuts, fraying or damage; do not use if 
damaged.  

Inspect drain hoses  

Inspect drain hose for kinks, breaks, or obstructions. Make 
sure the hose is draining properly. 

Inspect Exterior

  

Inspect exterior cabinet. Make sure air vents are free of any 
obstructions. Listen to the unit for abnormal sounds. For Parts 
and Service, call your local distributor or the Dri-Eaz Service 
Department at 800–932–3030. 

Clean Exterior

  

Clean the housing with a damp cloth. Make sure inlet and out-
let grills are free of dust and debris. 

PERIODIC MAINTENANCE 

Inspect and Clean Filter Element  

The CMC100 is equipped with a washable filter. Inspect the 
filter by removing the four filter door screws and sliding it out of 
the filter door panel (see Figure 2). If the filter shows excessive 
buildup, vacuum it clean and wash it in mild detergent. Replace 
the filter in the filter door and close the door securely.  

Note:

 

Do not operate the unit without the filter securely in 

place. If the filter becomes torn or can no longer be adequately 
cleaned, the filter may be replaced with similar cut-to-fit ma-
terial available at most hardware stores.

 

 

Inspect and Clean Pump  

If the unit no longer pumps water out of the drain line, the 
pump may be clogged with debris. Follow these steps to in-
spect and clean the pump system. 

 

WARNING! Unplug unit before cleaning or servicing

 

Tools needed 

Screwdriver 

Clean cloths 

Coil Cleaner (Available from Dri-Eaz, product no. S402) 

Vacuum cleaner with crevice tool 

 

 

Procedure 

1.  Remove the interchangeable side (see Fig. 4) and set 

aside. The panel is attached with four screws. 

2.  Remove the two drain line panel screws and set the panel 

down next to unit. The drain line is permanently attached to 
the interior of the panel and to the pump assembly. DO 
NOT REMOVE DRAIN LINE FROM PANEL OR FROM 
PUMP.  

Fig. 5: Remove the four pump bracket bolts  
from the CMC drain pan.  

Drain line panel  

Interchangeable panel 

Fig. 4: Remove two panels for access to 
pump 

Drain line panel  

Summary of Contents for CMC100

Page 1: ...ord to unplug The unit must be operated on a 115V 60 Hz circuit protected by a Ground Fault Interrupter GFI device This appliance is not intended for use by persons includ ing children with reduced physical sensory or mental ca pabilities or lack of experience and knowledge unless they have supervision or have been given instruction con cerning use of the appliance by a person responsible for thei...

Page 2: ... steady stream or not at all for short periods of time These functions indicate normal dehumi difier and pump purge operations NOTICE To avoid spills always secure the end of the drain hose so that the intermittent pumping action doesn t shift the hose out of position NOTICE Do not allow the outlet of the drain hose to become submerged blocked or otherwise subject to pressure that might reduce the...

Page 3: ...n you press the UP or DOWN buttons Af ter you have finished adjusting the setting the display will resume indicating the measured humidity and the CMC will automatically maintain humidity at the selected setting 2 In the STANDBY mode the display shows a double dash Unit does not operate in this mode Press the ON STANDBY button to return to ON mode Note The UP and DOWN buttons do not function in th...

Page 4: ...able filter Inspect the filter by removing the four filter door screws and sliding it out of the filter door panel see Figure 2 If the filter shows excessive buildup vacuum it clean and wash it in mild detergent Replace the filter in the filter door and close the door securely Note Do not operate the unit without the filter securely in place If the filter becomes torn or can no longer be adequatel...

Page 5: ...n 8 Inspect the drip tray Wipe clean with a cloth as necessary 9 Reattach the pump assembly to the pump bracket using the two bolts 10 Inspect the coil for dust accumulation Vacuum excess dust taking care not to damage any components Clean coils with Dri Eaz Coil Cleaner Be sure to wipe up any spills 11 Inspect the filter Clean in mild soap and water and dry tho roughly before reinstalling into th...

Page 6: ...ice Some values may be approximate PARTS INCLUDED WITH THE CMC Four leveling feet with mounting hardware 10 feet 3 meters of drain hose One hose clamp for attaching drain hose ADDITIONAL PRODUCT INFORMATION and current docu mentation is available at http cmc 100 dri eaz com FOR PARTS AND SERVICE CALL YOUR LOCAL DISTRIB UTOR or the Dri Eaz Service Department at 800 932 3030 www dri eaz com Visit wa...

Reviews: