Fig. 3: Parts Identification 

 

 

 

 

 

 

 

 

OPERATION  

1.  Plug in the power cord into a standard 115V grounded 

outlet. The unit must be operated on a 115V/60 Hz circuit 
protected by a Ground Fault Interrupter (GFI) device.  

2.  Attach one end of the drain hose to the condensate drain 

outlet and directing the other end into a drain or away from 
area to be kept dry. NOTICE: To prevent CMC100 drain 
pan overflow, ensure that there are no kinks or sharp 
bends in the drain hose and do not place the outlet of the 
hose higher than 3 ft. (1 m) above the top of the CMC100. 

3.  The CMC100 is controlled by an electronic touchpad hu-

midistat. The unit will automatically start when the humidity 
of the surrounding air exceeds the humidity level selected. 

4.  Set humidity set point with Control Panel (see below). 

 
CONTROL PANEL 

 

 

 

 

 

 

 

 

 

ON/STANDBY button 

  

The ON/STANDBY button toggles the unit between the ON 
and STANDBY modes. The display indicates the current mode.  

1.  In the 

ON

 mode, the display shows the current measured 

humidity as a percentage of relative humidity.  

 

To view the current humidity setting

, first set the unit in 

the ON mode, and then press the UP or DOWN arrow 
once.  

UP button  

 

DOWN button 

 

 

To change the humidity setting

, press the UP or DOWN 

button twice. Each time you press the button, the value of 
the humidity setting will increase or decrease in 5 percent 
increments.  

Note: In the ON mode, the display will show the humidity 
setting only when you press the UP or DOWN buttons. Af-
ter you have finished adjusting the setting, the display will 
resume indicating the measured humidity and the CMC 
will automatically maintain humidity at the selected setting. 

2.  In the 

STANDBY

 mode, the display shows a double dash. 

Unit does not operate in this mode. Press the 
ON/STANDBY button to return to ON mode. 

 

Note:

 The UP and DOWN buttons do not function in the 

Stand-by Mode. Press the ON/STANDBY button to 
resume operation. 

ADDITIONAL MODES

 

The CMC100 also has a DEFROST mode and a LOW TEM-
PERATURE PROTECTION mode. The unit automatically in-
itiates these modes as conditions warrant. No user intervention 
is required.  

1.  The CMC will automatically enter the 

DEFROST mode

 as 

needed. The fan will continue to operate until the unit is 
ready for the next operating cycle. The unit will automati-
cally return to ON mode when the defrost cycle is com-
plete.

 

 

2.  When the ambient temperature falls below 45°F (7°C), the 

unit enters 

LOW TEMPERATURE PROTECTION mode

 

and stops operating. The unit will automatically restart 
when the surrounding temperature rises above freezing. 

 

 

Automatic water pump out 

The unit automatically pumps out condensate through the con-
densate drain hose. No user intervention is required. 

Note:

 Check for proper operation before leaving the unit unat-

tended. Do not move the CMC100 while it is operating. 

Processed air 
outlet 

Condensate 
drain outlet 

Display 

ON/STANDBY 
button 

UP/DOWN 
buttons 

STANDBY mode 

DEFROST Mode  

LOW TEMPERATURE PRO-
TECTION Mode 

Interchangeable pa-
nels. See Optional 
Configurations, p. 2.  

Leveling foot-
pads (one on 
each corner)  

ON mode display 
shows current hu-
midity  

Indicates normal 
operating condi-
tions. 

Summary of Contents for CMC100

Page 1: ...ord to unplug The unit must be operated on a 115V 60 Hz circuit protected by a Ground Fault Interrupter GFI device This appliance is not intended for use by persons includ ing children with reduced physical sensory or mental ca pabilities or lack of experience and knowledge unless they have supervision or have been given instruction con cerning use of the appliance by a person responsible for thei...

Page 2: ... steady stream or not at all for short periods of time These functions indicate normal dehumi difier and pump purge operations NOTICE To avoid spills always secure the end of the drain hose so that the intermittent pumping action doesn t shift the hose out of position NOTICE Do not allow the outlet of the drain hose to become submerged blocked or otherwise subject to pressure that might reduce the...

Page 3: ...n you press the UP or DOWN buttons Af ter you have finished adjusting the setting the display will resume indicating the measured humidity and the CMC will automatically maintain humidity at the selected setting 2 In the STANDBY mode the display shows a double dash Unit does not operate in this mode Press the ON STANDBY button to return to ON mode Note The UP and DOWN buttons do not function in th...

Page 4: ...able filter Inspect the filter by removing the four filter door screws and sliding it out of the filter door panel see Figure 2 If the filter shows excessive buildup vacuum it clean and wash it in mild detergent Replace the filter in the filter door and close the door securely Note Do not operate the unit without the filter securely in place If the filter becomes torn or can no longer be adequatel...

Page 5: ...n 8 Inspect the drip tray Wipe clean with a cloth as necessary 9 Reattach the pump assembly to the pump bracket using the two bolts 10 Inspect the coil for dust accumulation Vacuum excess dust taking care not to damage any components Clean coils with Dri Eaz Coil Cleaner Be sure to wipe up any spills 11 Inspect the filter Clean in mild soap and water and dry tho roughly before reinstalling into th...

Page 6: ...ice Some values may be approximate PARTS INCLUDED WITH THE CMC Four leveling feet with mounting hardware 10 feet 3 meters of drain hose One hose clamp for attaching drain hose ADDITIONAL PRODUCT INFORMATION and current docu mentation is available at http cmc 100 dri eaz com FOR PARTS AND SERVICE CALL YOUR LOCAL DISTRIB UTOR or the Dri Eaz Service Department at 800 932 3030 www dri eaz com Visit wa...

Reviews: