Dri-Eaz 103614 (F600) Owner'S Manual Download Page 5

108259F #103614 (F600) 

Legend Brands, Inc. 

  Store and transport securely to avoid any 

damaging impact to internal parts.  

  Secure during transport to prevent sliding and 

possible injury to vehicle occupants. 

  Do not transport or store the unit on its front, sides 

or back. This will help to prevent any remaining 

moisture from escaping from the unit or flowing into 

areas outside the sump.  

MAINTENANCE SCHEDULE 

WARNING! ELECTRIC SHOCK HAZARD.

 Unplug the 

dehumidifier before performing any maintenance. 

WARNING: 

Risk of dust and contaminants exposure. 

Use of respirator mask and gloves is recommended. If 

unit has been exposed to potentially dangerous 

contaminants, clean thoroughly and sanitize before 

reuse.  

NOTICE:

 The unit is fitted with sensitive electronic 

sensors. Protect the sensors and their lead wires from 

damage and do not expose them to water or cleaning 

solution. 

The following tools and supplies are needed to 

complete the maintenance procedures described in 

this manual:  

Philips screwdriver 

T-20 Torx bit 

10 mm nutdriver or socket and ratchet 

Cleaning cloths  

HEPA vacuum cleaner with soft brush nozzle and 

crevice tool. 

Recommended 

Cordless drill, small knife, small-jaw pliers, coil 

cleaning solution, rotomolded housing cleaning 

solution. 

Before each use 

Inspect the electrical cord for damage.

 Look for 

fraying, cuts, etc. Replace the cord if you find any 

damage.  

Inspect filter. 

Replace if accumulation of dust and 

debris is visible.

 

 

NOTICE: Replace used filters only with a new Dri-Eaz 

filter part no. #100254 (F579) (24-pack). Other filter 

types do not provide adequate filtration or airflow. Each 

filter is individually wrapped to protect filtration 

effectiveness. Remove the wrapper before installing the 

filter into the dehumidifier. 

Monthly 

Inspect coils

. Clean when dust accumulation is visible. 

In normal use, dust can accumulate and can restrict 

airflow, reducing performance and causing the unit to 

overheat.  

To maintain appearance

, wipe interior and exterior 

surfaces with a damp cloth. For deep cleaning and a 

lasting, protective shine, use an automotive interior 

treatment product.  

As Needed 

Clean Pump Check Valve and Basin. 

This requires 

removal of the front housing.  

Clean coils.

 Inspect the horizontal evaporator (cold) coil 

with the front cover removed. If excessive dust and 

debris is present, vacuum thoroughly and/or clean with 

alkaline (non-acidic) coil cleaner.  

 

 

Remove the 4 

screws from front 

housing and slide 

off to access coils 

and pump for 

service.  

Fig. B: Disassembly for Cleaning 

Summary of Contents for 103614 (F600)

Page 1: ...o not use an extension cord The unit must be operated on a 115V 60Hz circuit protected by a Ground Fault Circuit Interrupter GFCI device Keep motor and wiring dry Do not attempt to repair the unit For...

Page 2: ...e entire hose and place the open end in a sink drain bucket or outdoors anywhere that water can drain out safely If you use a bucket or other container for water collection check it regularly to preve...

Page 3: ...plugged in Top display bar Job hours current time Press MENU to access settings and configuration controls Press PURGE to pump out condensate tank Press ON OFF to turn unit on Unit ON Press ON OFF ke...

Page 4: ...BLE Error W3 Flash Reset W4 WDT Reset Cycle power to dehumidifier If warning persists contact service AT THE END OF THE JOB To reduce the possibility of drips when moving the unit follow these additi...

Page 5: ...ss drill small knife small jaw pliers coil cleaning solution rotomolded housing cleaning solution Before each use Inspect the electrical cord for damage Look for fraying cuts etc Replace the cord if y...

Page 6: ...istance SPECIFICATIONS Model LGR 6000Li 103614 F600 Water removal AHAM 80 F 60 RH 100 pts 47 3 L day Water removal saturation 90 F 90 RH 204 pts 96 5 L day Process air max 320 CFM Dimensions H D W 32...

Page 7: ...o lo use Siempre sostenga el enchufe no el cable para desenchufar Inserte el enchufe de tres patas en un tomacorriente correspondiente con puesta a tierra No use un adaptador Nunca corte la tercera pa...

Page 8: ...a para su conexi n a la manguera de drenaje provista de 40 pies 12 m ubicado en la bandeja sobre la unidad Desenrolle la manguera completamente y coloque el extremo abierto en un lavabo drenaje cubo o...

Page 9: ...ara acceder a los controles de ajustes y configuraciones Presione PURGA para vaciar el tanque de condensado Presione ENCENDER APAGAR para encender la unidad Unidad ENCENDIDA Presione la tecla ENCENDER...

Page 10: ...rriente Si el error contin a comun quese con el servicio t cnico ER9 Error Bomba Obstruida Compruebe que no haya obstrucciones La manguera est acodada debajo de la unidad o aplastada por una rueda Ver...

Page 11: ...manual Destornillador Philips Broca T 20 Torx Llave para tuercas o llave de cubo y trinquete 10 mm Pa os de limpieza Aspiradora HEPA con una boquilla con cepillo blando y herramienta para cavidades Re...

Page 12: ...LGR 6000Li 103614 F600 Extracci n de agua AHAM 80 F 60 de humedad relativa 100 pintas 47 3 l d a Saturaci n de la extracci n de agua 90 F 90 de humedad relativa 204 pintas 96 5 l d a Dimensiones altur...

Page 13: ...ours la prise pas le c ble pour d brancher Ins rez la fiche triphas e du c ble d alimentation dans une prise de terre correspondante N utilisez pas d adaptateur Ne coupez jamais la troisi me broche N...

Page 14: ...ation pour attacher l unit dans un v hicule pour le transport Une telle utilisation exerce une pression excessive sur les points d attache de la poign e dans le logement Mise en place du tuyau de vida...

Page 15: ...res veuillez visiter la page du Contr leur i Series sur Controller LegendBrandsRestoration com Affichages cran d accueil Unit FERM E L unit doit tre branch e Barre d affichage sup rieure Heures de tra...

Page 16: ...loqu e V rifiez s il y a des obstructions Est ce que le tuyau est tordu sous l unit ou coinc sous une roue V rifiez que la pompe n est pas obstru e et corrigez si n cessaire W1 Basse BATTERIE Remplace...

Page 17: ...ou douille et cliquet Chiffons de nettoyage Aspirateur HEPA avec embout brosse douce et suceur plat Recommand Perceuse sans fil petit couteau petites pinces solution de nettoyage de serpentin solution...

Page 18: ...ECHNIQUES Mod le LGR 6000Li 103614 F600 limination de l eau AHAM 80 F 60 RH 100 pts 47 3 L jour limination de l eau Saturation 90 F 90 RH 204 pts 96 5 L jour Air de traitement max 320 CFM Dimensions H...

Reviews: